37-115-20582

Well Details

Well ID: 37-115-20582
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Liberty Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 147934
Farm/Lease Name: CARTY 7H
License Status: Inactive
Spud Date:
Permit Date: 2011-06-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.976744
Longitude: -75.779981

For data sources see[1][2][3]

Well History

Date Event
2011-06-07 New Permit Application
2011-06-10 Performed Spud Operation
2016-10-21 Inactive Well Request Granted

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2013 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2014 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2016 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2017 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2019 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 XPR RESOURCES LLC Produced Fluid 100.20 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2016 SWN PROD CO LLC Produced Fluid 256.75 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 27.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1992172 Primary Facility 2011-07-28 Routine/Complete Inspection No Violations Noted
2002327 Primary Facility 2011-09-13 Drilling/Alteration No Violations Noted Currently have H& P 272 over hole. Spudding in hole. Walked site with Company Man. Secondary containment in place. Discussed cuttings tanks and freeboard issues. While inspection the other three cellars on location, observed bubbling in two wells, and Company Man indicated bubbling was observed on the 3H, however, did not see that during this inspection. DEP will follow up.
2005404 Primary Facility 2011-09-15 Routine/Complete Inspection No Violations Noted
2364193 Primary Facility 2015-04-24 Routine/Complete Inspection No Violations Noted
2427910 Primary Facility 2015-11-25 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:35 a.m., the cellar was empty, there was cement between the (20x13) and (13x9) annuli’s and there was no gas detected, the (9x5) vent pipe was open and set up with a Taylor plug, there were no pressure gauges or lines on the well. I took a walk around the location and everything looked OK.
2491123 Primary Facility 2016-06-06 Routine/Complete Inspection No Violations Noted Inspection for inactive status request received on May 25, 2016.

At time of inspection, arrived on site at 1:35 p.m., the cellar had water at the bottom with no bubbling noticed, there was cement between the (20x13) and (13x9) annuli’s with no gas detected, there were no lines going to or from the well. I met with SWN well tender Jack Padula, Jack used a Crystal pressure gauge to get the pressures off the (9x5) annulus and 5.5 production casing, there was 132psi on the (9x5) annuli and 0psi on the production casing. There were three other wells on site (115-20576 1H), (115-20578 3H), (115-20580 5H) that were in production. There were no obvious concerns noticed at time of inspection. I left the site at 2:55 p.m.

2508861 Primary Facility 2016-05-06 Routine/Complete Inspection No Violations Noted Inspection of the Carty well pad in conjunction with the Northeast Gathering Pipeline - Line 408 pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2529605 Primary Facility 2016-10-14 Routine/Complete Inspection No Violations Noted Inspection in conjunction with the notice of termination inspection of the NE Gathering Pipeline 408. No E&S issues or spills noticed on the pad at the time of the inspection.
2617549 Primary Facility 2017-07-19 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:00a.m.

The cellar was full of water with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There were no lines going to or from the well. The well was granted inactive stasis on 10/21/16. I took a walk around the location and there were no obvious concerns noticed. I left the site at 10:40a.m.

2625274 Primary Facility 2017-08-11 Routine/Complete Inspection No Viols - Fac Inactive for Inspection The Department arrived on site at the WR 77- Carty Well Site to conduct a Routine Complete Inspection. A review of the E&S Inspection Log indicated that the most recent inspection was conducted on 8/7/17 with the note "monitor rills".

The status of this well is "Regulatory Inactive Status".

2722996 Primary Facility 2018-04-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was granted regulatory inactive status on 10/21/16. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. There were no lines going to or from the well. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2825221 Primary Facility 2019-01-10 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in and was granted regulatory inactive status on 10/21/16. There were no lines going to or from the well. The cellar was set up with a plastic corrugated pipe around the well for inspection access. The cellar was full of ice. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[7]