If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20596 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.717086,"lon":-75.835858,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Lathrop Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 145044 | |
Farm/Lease Name: NOBLE UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-06-28 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.717086 | |
Longitude: -75.835858 |
Date | Event |
---|---|
2011-06-28 | New Permit Application |
2011-12-16 | Performed Spud Operation |
2012-02-03 | Drilling Completion |
2012-04-01 | Perforation |
2012-04-01 | Performed Stimulation |
2012-08-17 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-04-11 | 2012-04-11 | 7,232 | 951,954 | |
2 | 2013-02-04 | 2013-02-04 | 7,232 | 2,223,186 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Scale Inhibitor - Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 0.01 | ||
Sand (Proppant) | Frac Tech Services (FTS) | Propping Agent | ||||||
Quartz | 14808-60-7 | 99.90 | 21.84 | |||||
Hydrochloric Acid 15 | Frac Tech Services (FTS) | Acid | Hydrochloric acid | 7647-01-0 | 0.63 | |||
Water | 7732-18-5 | |||||||
Biocide - Bactron K 139 | Champion Technologies | Biocide | benzyl-C12-16 alkyldimethyl,chlorides | |||||
Glutaraldehyde | 111-30-8 | 0.09 | ||||||
Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | |||||||
Ethanol | 64-17-5 | |||||||
Fresh Water | Base Fluid | Fresh Water | 100.00 | 77.33 | ||||
FRW-600 | Frac Tech Services (FTS) | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 0.08 | |||
2 | Water | Base Fluid | Fresh Water | 100.00 | 61.00 | |||
Hydrochloric Acid 28 | Halliburton Energy Services | Acid | Hydrochloric acid | 7647-01-0 | 0.54 | |||
Water 7732-18-5 85 |
||||||||
Gyptron T-390 Champion Technologies | Halliburton Energy Services | Scale Inhibitor | Methanol 67-56-1 10.00 |
0.01 | ||||
Gyptron T-390 Champion Technologies | Scale Inhibitor | |||||||
FRW-66 | Halliburton Energy Services | Friction Reducer | ||||||
Hydrotreated Light Distillate 64742-47-8 |
0.07 | |||||||
Sand (Proppant) | Halliburton Energy Services | Propping Agent | ||||||
Quartz | 14808-60-7 | 99.90 | 38.00 | |||||
Biocide - Bactron K 139 | Champion Technologies | Biocide | Quaternary ammonium compounds, benzyl-C12-16-alkyldimethyl, chlorides |
68424-85-1 | 10.00 | |||
Glutaraldehyde | 111-30-8 | 5.00 | 0.04 | |||||
Ethanol | 64-17-5 | 5.00 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-04-01 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHIEF OIL & GAS LLC | 482,120.00 | 203 | 0.00 | 0 | 0.00 | 0 |
2013 | CHIEF OIL & GAS LLC | 2,055,969.00 | 263 | 0.00 | 0 | 0.00 | 0 |
2014 | CHIEF OIL & GAS LLC | 1,306,403.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 684,091.12 | 358 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 777,151.35 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 749,990.41 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 492,446.24 | 333 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 507,071.15 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHIEF OIL & GAS LLC | Drill Cuttings | 21.39 Tons | LANDFILL | 100933 |
2012 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 625.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Produced Fluid | 1,378.70 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHIEF OIL & GAS LLC | Drill Cuttings | 1,133.41 Tons | LANDFILL | 100933 |
2013 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 352.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 103.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2013 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 54.24 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 330.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | CHIEF OIL & GAS LLC | Produced Fluid | 2,127.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHIEF OIL & GAS LLC | Produced Fluid | 924.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 179.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 193.46 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 77.84 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 19.79 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 96.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 375.41 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 294.11 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2145560 | Primary Facility | 2013-03-05 | Drilling/Alteration | No Violations Noted | Well has been recently re-stimulated, and is currently shut it waiting to be flowed back. Gauge on well shows @3600lbs. No bubbling in cellar. Secondary containment in place. Empty fresh water frac tanks on site. Re-use water storage tanks on site also. No activity on site at time of inspection. Only well spud on site. Permit on sign for #2 - but has not been drilled. Security guard at access point. Notification for re-stimulation was recieved. No violations observed. |
2145609 | Primary Facility | 2013-03-05 | Drilling/Alteration | No Violations Noted | Conductor is set @120'. Ziegenfuss set conductor. Moving Patterson 254 on site. Have six wells planned to be drilled on location. Only this well is spud at this time. Expect to be drilling in the next week or so. No violations observed at time of inspection. |
2154278 | Primary Facility | 2013-04-02 | Routine/Partial Inspection | No Violations Noted | |
2233399 | Primary Facility | 2014-01-02 | Drilling/Alteration | No Violations Noted | |
2346326 | Primary Facility | 2015-02-18 | Routine/Partial Inspection | No Violations Noted | The Department was on site at the Noble Unit well site, located at 1254 Noble Road Lathrop Township, to conduct a Routine Partial Inspection. Scott Kuchta (DEP-WQS) and I noted the following: The Site ID Sign is present and the E&S Plan is on site. The E&S Inspection Log indicated that Rick Ritter conducted an inspection on 2/11/15. The well site was covered in snow at the time of the inspection, no obvious E&S issues were found. The Department noted that the well tag for the 1H well was missing. |
2647849 | Primary Facility | 2017-08-11 | Routine/Complete Inspection | No Violations Noted | Today's inspection, 8/11/17 was conducted as a routine complete inspection. All 3 wells appeared to be in production. Compressor was running during the inspection. Gas utilized to run the compressor appears to be taken prior to the metering station. All three cellars were full of water with bull frogs living in each one. Site appears to be well maintained with no violations noted. |
2812775 | Primary Facility | 2018-12-10 | Routine/Complete Inspection | No Violations Noted | I performed a RTNC inspection of the Noble well pad. The weather was hovering around freezing to slightly below freezing and the skys were clear and sunny.
The access road was frozen and solid with no runoff observed. The well pad access gate was secured. The pad surface itself was frozen and partly snowcovered. The well pad appears to be in the midst of a modification, as the outer areas of the fill slopes were regraded and mulched, and matted on the steeper areas. The slopes all appeared stable. The mulch was applied evenly and thickly with no bare areas visible. There were old slopes visible with vegetation on them in profusion and no bare or unstable areas noted. The wells were properly labeled, and there was a compression unit running on site. There were no violations noted. |
2852397 | Primary Facility | 2019-03-12 | Routine/Complete Inspection | No Violations Noted | I inspected the Noble well pad on March 12. The weather was flurrying and about 30 degrees. The sky was mostly overcast.
The access road was solid and stable. The well pad was snowcovered and stable. A portion of the site has been reclaimed and was well mulched and stable. There were PCSMs constructed as well, which were blanketed and stable. The fill slope was well mulched and stable. The cut slope was vegetated and had no erosional issues apparent. The site, in general did not appear to have any erosional issues at the time of inspection. The wells were clearly labeled. There were no violations noted. |
For data sources see[9]