If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20691 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.904853,"lon":-75.838436,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Franklin Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 150595 | |
Farm/Lease Name: MITCHELL NORTH 1 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-10-18 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.904853 | |
Longitude: -75.838436 |
Date | Event |
---|---|
2011-10-18 | New Permit Application |
2012-01-13 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-03-10 | 2012-03-10 | 5,690 | 5,166,235 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WG-36 Gelling Agent | Halliburton Energy Services | Gel | |||||
Guar gum | 9000-30-0 | 100.00 | 0.00179000 | |||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | ||
SP Breaker | Halliburton Energy Services | Breaker | Sodium persulfate | 7775-27-1 | 100.00 | 0.00130000 | ||
Cla-Web | Halliburton Energy Services | Clay Control | ||||||
Proprietary | 60.00 | 0.02 | ||||||
Hydrochloric Acid | Halliburton Energy Services | Acid | Hydrochloric acid | 7647-01-0 | 30.00 | 0.13 | ||
Sand- Silica Sand | Halliburton Energy Services | Proppant | Quartz | 14808-60-7 | 100.00 | 13.99 | ||
Water | Carrier/Base Fluid | Water | 100.00 | 85.80 | ||||
BE-9M | Halliburton Energy Services | Biocide | Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 10.00 | 0.00472000 | ||
Methanol | 67-56-1 | 30.00 | 0.01 | |||||
GBW-30 Breaker | Halliburton Energy Services | Breaker | Carbohydrates | 95.00 | 0.00124000 | |||
Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00020000 | |||||
LP-65 | Halliburton Energy Services | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00388000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | XPR RESOURCES LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | XPR RESOURCES LLC | 561,512.85 | 213 | 0.00 | 0 | 0.00 | 0 |
2013 | XPR RESOURCES LLC | 655,862.73 | 323 | 0.00 | 0 | 0.00 | 0 |
2014 | XPR RESOURCES LLC | 582,744.39 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 443,794.95 | 362 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 451,740.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 178,458.00 | 267 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 169,318.00 | 288 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 259,082.00 | 335 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | XPR RESOURCES LLC | Fracing Fluid Waste | 15,316.92 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2012 | XPR RESOURCES LLC | Drilling Fluid Waste | 1,296.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
2012 | XPR RESOURCES LLC | Drill Cuttings | 1,484.52 Tons | LANDFILL | 100933 |
2013 | XPR RESOURCES LLC | Produced Fluid | 1,034.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 1,845.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | XPR RESOURCES LLC | Produced Fluid | 1,087.07 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC010 |
2013 | XPR RESOURCES LLC | Produced Fluid | 88.45 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 1,401.96 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2013 | XPR RESOURCES LLC | Produced Fluid | 1,574.35 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | XPR RESOURCES LLC | Produced Fluid | 653.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2013 | XPR RESOURCES LLC | Produced Fluid | 843.87 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2014 | XPR RESOURCES LLC | Produced Fluid | 402.51 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | XPR RESOURCES LLC | Produced Fluid | 3,648.30 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014 | XPR RESOURCES LLC | Produced Fluid | 239.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | XPR RESOURCES LLC | Produced Fluid | 1,156.58 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 1,618.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 2,026.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 702.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2017 | SWN PROD CO LLC | Produced Fluid | 380.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Produced Fluid | 201.67 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 13.75 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 2,888.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 108.53 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Waste Water Treatment Sludge | 1.50 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2018 | SWN PROD CO LLC | Produced Fluid | 439.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 491.97 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 20.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 7,409.57 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 11,911.50 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Soil Contaminated by Oil | 0.32 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 42.17 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 2,487.99 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 326.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Produced Fluid | 10,532.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 636.82 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 140.84 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Soil Contaminated by Oil & Gas Related Spills | 0.32 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | SWN PROD CO LLC | Synthetic Liner Materials | 12.00 Tons | LANDFILL | 100933 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2036933 | Primary Facility | 2012-01-11 | Routine/Complete Inspection | No Violations Noted | |
2093175 | Primary Facility | 2012-08-17 | Routine/Complete Inspection | No Violations Noted | Operator has requested to backfill the cellar around base of well. Proper well tag is in placeon well head. The cellar appears clean. At time of inspection there appeared to be no issues of concern. No violations observed. |
2347606 | Primary Facility | 2015-02-25 | Routine/Partial Inspection | No Violations Noted | |
2362988 | Primary Facility | 2015-04-20 | Routine/Complete Inspection | No Violations Noted | |
2431313 | Primary Facility | 2015-12-09 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 9:15 a.m., the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug, there was no gas detected at the perimeter of the cellar, there was 379psi on the production casing and 278psi on the production line. I took a walk around the location and everything looked OK. |
2508826 | Primary Facility | 2016-04-21 | Routine/Complete Inspection | No Violations Noted | Inspection of the Mitchell South well pad in conjunction with the HDK to Mitchell pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection. |
2520340 | Primary Facility | 2016-09-12 | Routine/Partial Inspection | No Violations Noted | |
2526680 | Primary Facility | 2016-10-07 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 11:25a.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure. There was 250psi on the production casing and 181psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 12:10p.m. |
2618595 | Primary Facility | 2017-07-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:55p.m.
The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was 338psi on the production casing and 248psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:45p.m. |
2723037 | Primary Facility | 2018-04-25 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of gravel with water setting on top and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2760271 | Primary Facility | 2018-07-30 | Routine/Complete Inspection | No Violations Noted | I inspected the Mitchell well pad on 07/30/2018 in response to a spill notification.
I met with company man Tommy Howard on site to perform an inspection. There apparently had been communication between the well bore and the mousehole which was discovered when a righand stepped on the plastic surrounding the hole and discovered it was puffed up with water. The water went back down shortly thereafter and there was no residual water after that initial discovery. The company had just started pumping cement and was just getting returns when it was discovered. The company is currently drilling on the Mitchell 1h. When the incident was noticed they had been running 13 3/8" surface casing which was just finished being flushed out with fresh water.
The cut and fill slopes are well vegetated and stable. The access road looked a bit weathered due to heavy traffic b |
2834151 | Primary Facility | 2019-01-30 | Incident- Response to Accident or Event | Violation(s) Noted | WQS Gene Rickard and I performed an INCDT inspection of the Mitchell well site regarding a reported release which occurred aroung 0830 on Jan. 30, 2019. The complaint number was 339494. The release was reported to me via Briana Cunningham, WQSS. Other individuals on site were Mike Deming and Mr. Otten of Southwestern Energy Production Co.
The weather at the time of inspection was around 15 degrees F and snowing. Wind was gusting. At about 0830 hrs. a tank in the onsite tank battery was being filled from a production fluid tank. The operator allegedly was monitoring the tank level from the hatch nearest the front part of the tank. According to a relayed assessment, the operator thought the tank was positioned not quite level, allowing the fluid level to overflow the back part of the tank, spilling onto the containment area surrounding the battery. The containment was later found to be compromised and allowed water to leave the containment area. SWN notified the Department on 1/30/2019. According to o |
2837776 | Primary Facility | 2019-02-08 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2834151 | 840893 | 2019-01-30 | CSL 402(b) | Environmental Health & Safety | Compromised liner that allowed produced water to escape containment allowed the pollutional substance to contact the pad surface resulting in the potential for impact of waters of the Commonwealth | |
2834151 | 840894 | 2019-01-30 | 78A57(A)___ | Environmental Health & Safety | A produced fluid tank was overfilled which caused production fluids to release onto compromised containment allowing the production fluids to impact the pad surface. | |
2834151 | 840895 | 2019-01-30 | SWMA 301 | Environmental Health & Safety | ||
2834151 | 840896 | 2019-01-30 | OGA3218.2(A) | Environmental Health & Safety | During transfer of produced fluid from the produced water tank to the onsite tank battery, a tank in battery overflowed to compromised containment resulting in an impact of the pad surface by the pollutional substance. |
For data sources see[8]