X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20697

Well Details

Well ID: 37-115-20697
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Franklin Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150595
Farm/Lease Name: MITCHELL SOUTH 1 8H
License Status:
Spud Date:
Permit Date: 2011-10-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.904769
Longitude: -75.838408

For data sources see[1][2][3]

Well History

Date Event
2011-10-18 New Permit Application
2011-12-10 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-03-30 2012-03-30 5,970 4,200,039

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 WG-36 Gelling Agent Halliburton Energy Services Gel
Guar gum 9000-30-0 100.00 0.00220000
LP-65 Halliburton Energy Services Scale Inhibitor Ammonium chloride 12125-02-9 10.00 0.00376000
FR-66 Friction Reducer Halliburton Energy Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
SP Breaker Halliburton Energy Services Breaker Sodium persulfate 7775-27-1 100.00 0.00192000
Sand- Silica Sand Halliburton Energy Services Proppant Quartz 14808-60-7 100.00 15.45
Water Carrier/Base Fluid Water 100.00 84.33
Cla-Web Halliburton Energy Services Clay Control
Proprietary 60.00 0.02
Hydrochloric Acid Halliburton Energy Services Acid Hydrochloric acid 7647-01-0 30.00 0.14
GBW-30 Breaker Halliburton Energy Services Breaker
Carbohydrates 95.00 0.00182000
Hemicellulase enzyme 9012-54-8 15.00 0.00029000
BE-9M Halliburton Energy Services Biocide
Methanol 67-56-1 30.00 0.00694000
Tri-n-butyl tetradecyl phosphonium chloride 81741-28-8 10.00 0.00231000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2012 XPR RESOURCES LLC 774,652.53 213 0.00 0 0.00 0
2013 XPR RESOURCES LLC 920,641.44 348 0.00 0 0.00 0
2014 XPR RESOURCES LLC 757,926.85 365 0.00 0 0.00 0
2015 SWN PROD CO LLC 516,416.96 362 0.00 0 0.00 0
2016 SWN PROD CO LLC 577,994.00 366 0.00 0 0.00 0
2017 SWN PROD CO LLC 186,440.00 224 0.00 0 0.00 0
2018 SWN PROD CO LLC 275,245.00 265 0.00 0 0.00 0
2019 SWN PROD CO LLC 237,054.00 271 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 XPR RESOURCES LLC Fracing Fluid Waste 10,781.60 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2013 XPR RESOURCES LLC Produced Fluid 457.31 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 XPR RESOURCES LLC Produced Fluid 530.19 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2013 XPR RESOURCES LLC Produced Fluid 1,797.28 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2013 XPR RESOURCES LLC Produced Fluid 1,010.21 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 1,337.03 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2013 XPR RESOURCES LLC Produced Fluid 207.19 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123
2013 XPR RESOURCES LLC Produced Fluid 1,170.85 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC010
2013 XPR RESOURCES LLC Produced Fluid 108.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123SW018
2014 XPR RESOURCES LLC Produced Fluid 66.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 XPR RESOURCES LLC Produced Fluid 3,611.77 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2014 XPR RESOURCES LLC Produced Fluid 101.43 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 XPR RESOURCES LLC Produced Fluid 960.81 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 SOUTHWESTERN ENERGY PROD CO Produced Fluid 2,841.25 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 155.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 SWN PROD CO LLC Produced Fluid 2,150.00 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 13.75 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 1,401.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 55.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 20.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 108.53 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 439.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 11,746.50 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 7,409.57 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Waste Water Treatment Sludge 1.50 Tons RESIDUAL WASTE PROCESSING FACILITY 2014-541
2018 SWN PROD CO LLC Other Oil & Gas Wastes 491.97 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 326.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 10,532.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 636.82 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Soil Contaminated by Oil 0.32 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2019 SWN PROD CO LLC Produced Fluid 140.84 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 2,487.99 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 42.17 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.32 Tons RESIDUAL WASTE PROCESSING FACILITY 301333

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2036961 Primary Facility 2012-01-11 Routine/Complete Inspection No Violations Noted
2093178 Primary Facility 2012-08-17 Routine/Complete Inspection No Violations Noted Operator has requested to backfill the cellar around base of well. Proper well tag is in placeon well head. The cellar appears clean. At time of inspection there appeared to be no issues of concern. No violations observed.
2347611 Primary Facility 2015-02-25 Routine/Partial Inspection No Violations Noted
2362994 Primary Facility 2015-04-20 Routine/Complete Inspection No Violations Noted
2431321 Primary Facility 2015-12-09 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:15 a.m., the cellar was full of gravel, the vent pipe was open and set up with a Taylor plug, there was no gas detected at the perimeter of the cellar, there was 382psi on the production casing and 277psi on the production line. I took a walk around the location and everything looked OK.
2508823 Primary Facility 2016-04-21 Routine/Complete Inspection No Violations Noted Inspection of the Mitchell South well pad in conjunction with the HDK to Mitchell pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection.
2520344 Primary Facility 2016-09-12 Routine/Partial Inspection No Violations Noted
2526689 Primary Facility 2016-10-07 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:25a.m., the cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The vent pipe was open and set up with a Taylor plug to check for pressure. There was 270psi on the production casing and 184psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 12:10p.m.

2618600 Primary Facility 2017-07-21 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:55p.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was 508psi on the production casing and 502psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:45p.m.

2723109 Primary Facility 2018-04-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2760278 Primary Facility 2018-07-30 Routine/Complete Inspection No Violations Noted I inspected the Mitchell well pad on 07/30/2018 in response to a spill notification.

I met with company man Tommy Howard on site to perform an inspection. There apparently had been communication between the well bore and the mousehole which was discovered when a righand stepped on the plastic surrounding the hole and discovered it was puffed up with water. The water went back down shortly thereafter and there was no residual water after that initial discovery. The company had just started pumping cement and was just getting returns when it was discovered. The company is currently drilling on the Mitchell 1h. When the incident was noticed they had been running 13 3/8" surface casing which was just finished being flushed out with fresh water.


When the rig moves off, the site will be checked out after the plastic is removed and screened for contamination according to the company man.

The cut and fill slopes are well vegetated and stable.

The access road looked a bit weathered due to heavy traffic b

2837785 Primary Facility 2019-02-08 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was shut in at the GPU by a main valve on the inlet line. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[8]

References