X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-20834

Well Details

Well ID: 37-115-20834
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149125
Farm/Lease Name: R CAREY 3
License Status:
Spud Date:
Permit Date: 2012-01-19
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.749997
Longitude: -75.689864

For data sources see[1][2][3]

Well History

Date Event
2012-01-19 New Permit Application
2012-02-13 Performed Spud Operation
2012-04-08 Drilling Completion
2012-06-23 Perforation
2012-06-23 Performed Stimulation
2013-05-29 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-06-12 2012-06-12 7,204 6,066,732

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 PA Specific 100 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Ferric oxide 1309-37-1 0.10 0.00060800
Quartz 14808-60-7 99.90 0.60
Alumina 1344-28-1 1.10 0.00669300
Titanium dioxide 13463-67-7 0.10 0.00060800
Acid Inhibitor 2 (AI-2) Superior Well Services Acid Corrosion Inhibitor Isopropanol 67-63-0 15.00 0.00014900
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-

,
branched

68412-54-4 13.00 0.00012900
Propargyl alcohol 107-19-7 20.00 0.00019900
Water 7732-18-5 40.00 0.00039700
Tar bases, quinoline derivatives,
benzyl chloride-quaternized
72480-70-7 10.00 0.00009900
Glycol Ethers 20.00 0.00019900
PA Specific 40/70 mesh Sand Superior Well Services Sand - Bulk - Pennsylvania Alumina 1344-28-1 1.10 0.11
Titanium dioxide 13463-67-7 0.10 0.01
Ferric oxide 1309-37-1 0.10 0.01
Quartz 14808-60-7 99.90 10.74
Iron Acid 10M (12.6-18.0) Superior Well Services Acid Blend Water 7732-18-5 84.10 0.49
Proprietary 1.20 0.00709400
Hydrochloric acid 7647-01-0 15.80 0.09
Water Carrier/Base Fluid 100.00 87.69
KR-153SL Superior Well Services Biocide Water 7732-18-5 80.00 0.02
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00554300
Super TSC LT Superior Well Services Paraffin & Scale Additive 0.00372900
Proprietary 15.00
Proprietary 15.00 0.00372900
Proprietary 50.00 0.01
Water 7732-18-5 60.00 0.01
WFR-3B Superior Well Services Friction Reducer Ethoxylated C12-16 alcohols 68551-12-2 15.00 0.01
Distillates, petroleum, hydrotreated light 64742-47-8 50.00 0.04
1,2-Propylene glycol 57-55-6 15.00 0.01
Water 7732-18-5 40.00 0.03
1,2-Propylene glycol 57-55-6 40.00 0.03
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy
-
26635-93-8 5.00 0.00441800
Microparticle 1.00 0.00088400

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2012-06-23 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2013 CABOT OIL & GAS CORP 2,249,901.80 263 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 1,423,965.84 357 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 842,061.13 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 721,606.02 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 565,421.44 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 628,215.00 365 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 627,945.00 328 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CABOT OIL & GAS CORP Drill Cuttings 918.48 Tons LANDFILL NY STATE #32S11
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 17.57 Tons LANDFILL 101534
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 647.93 Bbl LANDFILL NY STATE #32S11
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1,210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 9.66 Tons LANDFILL 100081
2012 CABOT OIL & GAS CORP Drill Cuttings 370.63 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 14,337.01 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 0.02 Tons LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracturing Fluid Waste 8.17 Tons LANDFILL 100945
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 12.30 Bbl LANDFILL 101534
2012 CABOT OIL & GAS CORP Drilling Fluid Waste 1,220.66 Bbl LANDFILL THR029
2012 CABOT OIL & GAS CORP Fracing Fluid Waste 4,467.13 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2013 CABOT OIL & GAS CORP Produced Fluid 234.45 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 895.37 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Produced Fluid 100.50 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 1,467.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 636.81 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.12 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 257.20 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 13.42 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 179.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 59.63 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 133.86 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 69.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 334.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 51.07 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 103.27 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 321.82 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 6.08 Tons REUSE (AT WELL PAD)
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 2.50 Tons RESIDUAL WASTE TRANSFER FACILITY 101714

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2142778 Primary Facility 2012-11-01 Routine/Complete Inspection No Violations Noted At time of inspection, workover rig on site on R. Carey 2H. R. Carey 3H has been completed and fracced. Gauges on well show 0 psi. Well is currently shut in. No bubbling observed in cellar. No violations observed pertaining to this well at time of site inspection.
2354802 Primary Facility 2015-03-25 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection on the R. Carey well pad. Permits associated with this site are:
2468301 Primary Facility 2016-03-25 Routine/Complete Inspection No Violations Noted
2489255 Primary Facility 2016-06-01 Routine/Complete Inspection No Violations Noted
2503643 Primary Facility 2016-07-22 Routine/Complete Inspection No Violations Noted
2505981 Primary Facility 2016-07-22 Routine/Complete Inspection No Violations Noted
2530762 Primary Facility 2016-10-21 Routine/Complete Inspection No Violations Noted On 10/21/16, the Department conducted an inspection of the COG Carey R. Pad located in Harford Township, Susquehanna County. 3 Wells have been drilled on this pad and appear to be in production, the 1H, the 2H, and the 3H. The well pad and adjoining tank pad have good stabilization. There were 2 standing water puddles located on the well pad. Both puddles were tested with an Extech Exstik II Conductivity Meter. Both revealed measurements of 200 microsiemens. Next, the conductivity of the standing water within the production tank containment was measured and found to be at 600 microsiemens. There was approximately 3” of water in this containment. A Time Extension Request has been granted for the ESCGP for this site by the Department and will be effective until September 30, 2017. No violations noted.
2586417 Primary Facility 2017-04-20 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 14:35p.m.

The cellar was about a quarter full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 508psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 15:10p.m.

2605905 Primary Facility 2017-06-20 Routine/Complete Inspection No Violations Noted Todays inspection was conducted to assess the site after having received notification of a nearby water supply complaint. Entire site is stable. Roadside ditches are in excellent condition. All 3 wells, the 1H, 2H and 3H all appear to be in production. No violations noted.
2616398 Primary Facility 2017-07-18 Routine/Complete Inspection No Violations Noted Todays inspection was conducted to assess the site after having received notification of a nearby water supply complaint. Entire site is stable. Roadside ditches are in excellent condition. All 3 wells, the 1H, 2H and 3H all appear to be in production. No violations noted.
2690754 Primary Facility 2018-02-02 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2791427 Primary Facility 2018-10-18 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 7' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2812679 Primary Facility 2018-11-29 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues were noted. Photo #4 shows the fill slope with a high number of shot gun shell casing present, suggesting site is utilized as a clay bird shooting location. No violations noted.

For data sources see[9]

References