{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.749997,"lon":-75.689864,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Harford Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 149125 | |
Farm/Lease Name: R CAREY 3 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-01-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.749997 | |
Longitude: -75.689864 |
Date | Event |
---|---|
2012-01-19 | New Permit Application |
2012-02-13 | Performed Spud Operation |
2012-04-08 | Drilling Completion |
2012-06-23 | Perforation |
2012-06-23 | Performed Stimulation |
2013-05-29 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-06-12 | 2012-06-12 | 7,204 | 6,066,732 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | PA Specific 100 mesh Sand | Superior Well Services | Sand - Bulk - Pennsylvania | Ferric oxide | 1309-37-1 | 0.10 | 0.00060800 | |
Quartz | 14808-60-7 | 99.90 | 0.60 | |||||
Alumina | 1344-28-1 | 1.10 | 0.00669300 | |||||
Titanium dioxide | 13463-67-7 | 0.10 | 0.00060800 | |||||
Acid Inhibitor 2 (AI-2) | Superior Well Services | Acid Corrosion Inhibitor | Isopropanol | 67-63-0 | 15.00 | 0.00014900 | ||
Poly(oxy-1,2-ethanediyl), alpha-(nonylphenyl)-omega-hydroxy-
, |
68412-54-4 | 13.00 | 0.00012900 | |||||
Propargyl alcohol | 107-19-7 | 20.00 | 0.00019900 | |||||
Water | 7732-18-5 | 40.00 | 0.00039700 | |||||
Tar bases, quinoline derivatives, benzyl chloride-quaternized |
72480-70-7 | 10.00 | 0.00009900 | |||||
Glycol Ethers | 20.00 | 0.00019900 | ||||||
PA Specific 40/70 mesh Sand | Superior Well Services | Sand - Bulk - Pennsylvania | Alumina | 1344-28-1 | 1.10 | 0.11 | ||
Titanium dioxide | 13463-67-7 | 0.10 | 0.01 | |||||
Ferric oxide | 1309-37-1 | 0.10 | 0.01 | |||||
Quartz | 14808-60-7 | 99.90 | 10.74 | |||||
Iron Acid 10M (12.6-18.0) | Superior Well Services | Acid Blend | Water | 7732-18-5 | 84.10 | 0.49 | ||
Proprietary | 1.20 | 0.00709400 | ||||||
Hydrochloric acid | 7647-01-0 | 15.80 | 0.09 | |||||
Water | Carrier/Base Fluid | 100.00 | 87.69 | |||||
KR-153SL | Superior Well Services | Biocide | Water | 7732-18-5 | 80.00 | 0.02 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00554300 | |||||
Super TSC LT | Superior Well Services | Paraffin & Scale Additive | 0.00372900 | |||||
Proprietary | 15.00 | |||||||
Proprietary | 15.00 | 0.00372900 | ||||||
Proprietary | 50.00 | 0.01 | ||||||
Water | 7732-18-5 | 60.00 | 0.01 | |||||
WFR-3B | Superior Well Services | Friction Reducer | Ethoxylated C12-16 alcohols | 68551-12-2 | 15.00 | 0.01 | ||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 50.00 | 0.04 | |||||
1,2-Propylene glycol | 57-55-6 | 15.00 | 0.01 | |||||
Water | 7732-18-5 | 40.00 | 0.03 | |||||
1,2-Propylene glycol | 57-55-6 | 40.00 | 0.03 | |||||
Poly(oxy-1,2-ethanediyl), .alpha.,.alpha.'-[[(9Z)-9-octadecenylimino]di-2,1-ethanediyl]bis[.omega.-hydroxy - |
26635-93-8 | 5.00 | 0.00441800 | |||||
Microparticle | 1.00 | 0.00088400 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2012-06-23 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CABOT OIL & GAS CORP | 2,249,901.80 | 263 | 0.00 | 0 | 0.00 | 0 |
2014 | CABOT OIL & GAS CORP | 1,423,965.84 | 357 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 842,061.13 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 721,606.02 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 565,421.44 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 628,215.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 627,945.00 | 328 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CABOT OIL & GAS CORP | Drill Cuttings | 918.48 Tons | LANDFILL | NY STATE #32S11 |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 17.57 Tons | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 647.93 Bbl | LANDFILL | NY STATE #32S11 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,210.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 9.66 Tons | LANDFILL | 100081 |
2012 | CABOT OIL & GAS CORP | Drill Cuttings | 370.63 Tons | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 14,337.01 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 0.02 Tons | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracturing Fluid Waste | 8.17 Tons | LANDFILL | 100945 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 12.30 Bbl | LANDFILL | 101534 |
2012 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 1,220.66 Bbl | LANDFILL | THR029 |
2012 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 4,467.13 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 234.45 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 895.37 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2013 | CABOT OIL & GAS CORP | Produced Fluid | 100.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE001 |
2014 | CABOT OIL & GAS CORP | Produced Fluid | 1,467.17 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 636.81 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 4.12 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 257.20 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 13.42 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NE004 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 179.79 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 59.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 133.86 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 69.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 334.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 51.07 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 103.27 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 321.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE004 |
2019 | CABOT OIL & GAS CORP | Waste Water Treatment Sludge | 6.08 Tons | REUSE (AT WELL PAD) | |
2019 | CABOT OIL & GAS CORP | Synthetic Liner Materials | 2.50 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2142778 | Primary Facility | 2012-11-01 | Routine/Complete Inspection | No Violations Noted | At time of inspection, workover rig on site on R. Carey 2H. R. Carey 3H has been completed and fracced. Gauges on well show 0 psi. Well is currently shut in. No bubbling observed in cellar. No violations observed pertaining to this well at time of site inspection. |
2354802 | Primary Facility | 2015-03-25 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct a routine complete inspection on the R. Carey well pad. Permits associated with this site are: |
2468301 | Primary Facility | 2016-03-25 | Routine/Complete Inspection | No Violations Noted | |
2489255 | Primary Facility | 2016-06-01 | Routine/Complete Inspection | No Violations Noted | |
2503643 | Primary Facility | 2016-07-22 | Routine/Complete Inspection | No Violations Noted | |
2505981 | Primary Facility | 2016-07-22 | Routine/Complete Inspection | No Violations Noted | |
2530762 | Primary Facility | 2016-10-21 | Routine/Complete Inspection | No Violations Noted | On 10/21/16, the Department conducted an inspection of the COG Carey R. Pad located in Harford Township, Susquehanna County. 3 Wells have been drilled on this pad and appear to be in production, the 1H, the 2H, and the 3H. The well pad and adjoining tank pad have good stabilization. There were 2 standing water puddles located on the well pad. Both puddles were tested with an Extech Exstik II Conductivity Meter. Both revealed measurements of 200 microsiemens. Next, the conductivity of the standing water within the production tank containment was measured and found to be at 600 microsiemens. There was approximately 3” of water in this containment. A Time Extension Request has been granted for the ESCGP for this site by the Department and will be effective until September 30, 2017. No violations noted. |
2586417 | Primary Facility | 2017-04-20 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:35p.m.
The cellar was about a quarter full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 508psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 15:10p.m. |
2605905 | Primary Facility | 2017-06-20 | Routine/Complete Inspection | No Violations Noted | Todays inspection was conducted to assess the site after having received notification of a nearby water supply complaint. Entire site is stable. Roadside ditches are in excellent condition. All 3 wells, the 1H, 2H and 3H all appear to be in production. No violations noted. |
2616398 | Primary Facility | 2017-07-18 | Routine/Complete Inspection | No Violations Noted | Todays inspection was conducted to assess the site after having received notification of a nearby water supply complaint. Entire site is stable. Roadside ditches are in excellent condition. All 3 wells, the 1H, 2H and 3H all appear to be in production. No violations noted. |
2690754 | Primary Facility | 2018-02-02 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The (13x9) and (9x5) annuli vent pipes were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2791427 | Primary Facility | 2018-10-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 7' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was no gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2812679 | Primary Facility | 2018-11-29 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were noted. Photo #4 shows the fill slope with a high number of shot gun shell casing present, suggesting site is utilized as a clay bird shooting location. No violations noted. |