Well Details

Well ID: 37-115-20848
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Lenox Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 144713
Farm/Lease Name: SHIVELY SORENSON 2H
License Status: Plugged and Abandoned
Spud Date: 2012-02-04
Permit Date: 2012-02-03
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.659036
Longitude: -75.689583

For data sources see[1][2][3]

Well History

Date Event
2012-02-03 New Permit Application
2012-02-05 Performed Spud Operation
2013-02-28 New Permit Application
2013-05-27 Drilling Completion
2014-03-09 Perforation
2014-03-09 Performed Stage 1 of Stimulation
2014-03-09 Performed Stage 2 of Stimulation
2014-03-10 Perforation
2014-03-10 Performed Stage 3 of Stimulation
2014-03-10 Performed Stage 4 of Stimulation
2014-03-10 Performed Stage 5 of Stimulation
2015-12-07 Inactive Well Request Granted
2016-11-03 Begin Plugging
2016-11-11 Finished Plugging
2017-04-27 Deviated
2017-04-27 Fully Plugged

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-03-09 2014-03-10 7,491 1,885,880 0
2 2017-10-27 2017-11-03 6,292 8,430,580 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Customer & CWS Base Fluid & Mix Water Water 7732-18-5 100 88.1324 15,841,500.0
Sand (Proppant), DAP-901, DAP-925,
DWP-603, BioClear 2000, DWP-NE1, Hydrochloric Acid
CWS Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Friction Reducer, Biocide, Non-Emulsifier, Clean Perforations 2,2-Dibromo-3-Nitrilopropionamide 10222-01-2 40 0.01291 2321.02
Oxyalkylated polyamine Proprietary 5 0.00072 129.13
Paraffinic hydrocarbon solvent 64742-47-8 30 0.01765 3171.94
Polyoxyalkylenes Proprietary 30 0.0002 35.92
Calcite 471-34-1 1 0.01396 2509.42
Formaldehyde 50-00-0 0.1 0.00002000 4.25
Organic phosphonate 1 Proprietary 30 0.00431 774.77
Polyethylene glycol mixture 25322-68-3 70 0.01291 2321.02
Apatite 64476-38-6 0.1 0.00517 928.86
Amine salt Proprietary 5 0.00072 129.13
Modified thiourea polymer 68527-49-1 30 0.0002 35.92
Ilmenite 98072-94-7 0.1 0.0045 809.36
Dimethylcocoamine, bis(chloroethyl)
ether, diquaternary ammonium salt
68607-28-3 40 0.01761 3164.53
Methanol 67-56-1 60 0.01131 2033.3
Ammonium chloride 12125-02-9 10 0.00186 334.5
Sodium chloride 7647-14-5 1 0.00001000 1.2
Illite 12173-60-3 1 0.01216 2185.27
Goethite 1310-14-1 0.1 0.0065 1167.85
Sorbitan monooleate 1338-43-8 5 0.00333 598.48
Propargyl Alcohol 107-19-7 10 0.00007000 11.97
Isopropanol 67-63-0 40 0.01761 3164.53
Olefin Proprietary 5 0.00003000 5.99
Hydrochloric acid 7647-01-0 37 0.59828 107538
Acetic acid 64-19-7 1 0.00014 25.83
Crystalline silica (Quartz) 14808-60-7 100 11.0898 1,993,360.0
Organic phosphonate 2 Proprietary 10 0.00144 258.26
Poly(oxyethylene)nonylphenol ether 9016-45-9 5 0.00333 598.48
Diallyldimethylammonium chloride 7398-69-8 5 0.0022 395.57
Fatty acids Proprietary 30 0.0002 35.92
Poly(Acrylamide and Adam methyl Chloride) 69418-26-4 40 0.02331 4189.35
Biotite 1302-27-8 0.1 0.00517 928.86
2 HAI-150E Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 85.8743 70,226,500.0
SAND-COMMON WHITE - 100 MESH, 3307 LB BAG Halliburton Proppant Listed Below Listed Below 0 0 0
BE-9 Halliburton Biocide Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 1.12762 922152
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
LP-65 MC Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
Hydrotreated light petroleum distillate 64742-47-8 30 0.0287678 23526
Hydrochloric acid 7647-01-0 60 0.152383 124616
Diammonium phosphate 7783-28-0 5 0.00116836 956
Non-hazardous food substance Proprietary 100 0.000310596 254
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00401838 3287
Crystalline silica, quartz 14808-60-7 100 12.9501 10,590,300.0
Inorganic salt Proprietary 30 0.0287678 23526
Ammonium chloride 12125-02-9 30 0.00701016 5733
Acrylamide acrylate copolymer Proprietary 30 0.0287678 23526
Organic phosphonate Proprietary 60 0.0140203 11466

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-03-09 1 SAND 1,920,912 7,673 6,992
2014-03-09 2 SAND 1,920,912 7,582 7,052
2014-03-10 3 SAND 1,920,912 7,571 7,469
2014-03-10 4 SAND 1,920,912 7,657 7,295
2014-03-10 5 SAND 1,920,912 7,787 7,639

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2012 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2013 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2016 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,378.00 Tons LANDFILL NY STATE #32S11
2012 SOUTHWESTERN ENERGY PROD CO Drilling Fluid Waste 242.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2012 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,104.00 Tons LANDFILL THR029
2013 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 470.98 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Produced Fluid 4,432.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 7,429.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 56.72 Tons LANDFILL THR029
2015 SWN PROD CO LLC Produced Fluid 157.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Synthetic Liner Materials 7.00 Tons LANDFILL 101247
2016 SWN PROD CO LLC Drilling Fluid Waste 1,194.48 Bbl LANDFILL THR029
2016 SWN PROD CO LLC Fracturing Fluid Waste 1,357.00 Bbl REUSE OTHER THAN ROAD SPREADING

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2047068 Primary Facility 2012-02-28 Drilling/Alteration No Violations Noted Falcon 23. Drilling ahead at 750'. Secondary containment in place. Will be setting 13 3/8" at 935'. Will drill out and set 9 5/8" at 1600'. Will drill down to KOP then mobilize to next location. Asked Operator to notify DEP when mobilize to next location.
2378830 Primary Facility 2015-06-08 Routine/Complete Inspection No Violations Noted
2485153 Primary Facility 2016-05-16 Routine/Complete Inspection No Violations Noted
2525647 Primary Facility 2016-10-04 Routine/Complete Inspection No Violations Noted
2530528 Primary Facility 2016-10-19 Routine/Complete Inspection No Violations Noted Pre-plugging inspection of SWN’s Shively Sorenson well in Lenox Twp. Susquehanna County conducted October 19, 2016 at 10:45 am. Operator has sent Notice of Intent and plugging prognosis for review. At the time of inspection; I met with SWN on location. The 2H has a production tree in place, shut-in, not tied into pipeline. Analog pressure gauge at the tree top (tubing) and wing valve (prod. csg.) both show approx. 3300 PSI, verified with SWN well tender’s crystal gauge at taylor plug valves. The Crystal Gauge broke when the well tender went to check the pressure on the backside of the production casing (“9 x 5”) annulus, so he opened up the valve on the otherside of the 9 5/8” casinghead up to a fluid-filled gauge; 0 PSI on the backside of production casing. I asked him for SWN to contact me if there is any pressure on the annulus after verifying with a different crystal gauge later in the day. The cellar was empty. The 9 5/8” csg’s annulus had water on the cement top; no bubbling or gas verified with Altair
2534422 Primary Facility 2016-11-03 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of SWN’s Shively Sorenson 2H in Lenox Twp. Susquehanna County conducted November 3rd, 2016 at 1 pm. CWS workover rig was staged on the pad for P&A operations. At the time of inspection; slickline was rigged up on the well with tools stuck in the hole. Well kill fluid being pumped. Once tools are recovered the rig will continue P&A procedure; pull tubing, set CIBP and set balanced cmt plug in days to follow. I plan to return after the rig pulls production casing and sets balanced cement plugs back from the stub-openhole and in openhole – back across 9 5/8” shoe. No major concerns at this time.
2535459 Primary Facility 2016-11-09 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of SWN’s Shively Sorenson 2H in Lenox Twp. Susquehanna County conducted November 9rd, 2016 at 10:30 am. CWS workover rig was rigged up on the well for P&A operations. O-TEX Cementers were spotting in and rigging up. I met with the Companyman to discuss operations on the pad since my last visit 11/3. CIBP was set at 7202’, balanced cmt plug set on top; the rig tagged plug at 7015’. Stretch test indicated estimated TOC @ 3200’. 1st 5 ½” csg cut was made at 2952’, pulled 60K over w/ no success, made 2nd cut at 2492’ and pulled casing. We went over depths and volumes for remaining balanced cement plugs. O-TEX rigged up to circulate mud out the hole w/gel and cement. No Issues.
2537569 Primary Facility 2016-11-15 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of SWN’s Shively Sorenson 2H in Lenox Twp. Susquehanna County conducted November 15, 2016 at 11:40 am to conduct inspection of adequacy of plugging after last week’s plugging operations. At the time of inspection, the casinghead on the 9 5/8” had marker cap welded flush with flange. In addition; Nipple/ ball valves have been removed from the side outlets welded closed, disallowing access to the wellbore before burial. Cap was welded approx. 1 day after mixing, pumping, and spotting production csg stub isolation plug and the 9 5/8” shoe plug, and approx. 2 hours after mixing, pumping, and spotting last (2) balance cement plugs inside the 9 5/8”. I contacted the operator in phone conversation from the pad to discuss the obvious problems with this practice. Operator plans to cut the abandonment cap to allow access to the wellbore in order to evaluate the adequacy of plugging to verify the job was successful. No violations cited at this moment.
2539816 Primary Facility 2016-11-21 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of SWN’s Shively Sorenson 2H in Lenox Twp. Susquehanna County conducted November 21, 2016 at 10:55 am. At time of inspection; 2” pipe nipple tapped into well abandonment cap w/valve, 2”x 1/2” reducer coupling, needle valve. I opened the 2” valve and needle valve; needle valve was full of ice. Shut in the 2”, removed the needle valve, opened the 2”, pipe nipple had obstruction inside where it threaded onto the marker cap. I poked through obstruction in nipple with steel rod and took a field reading with an Altair 5x gas meter which yielded 6% LEL. I installed a 0-150PSI analog pressure gauge on the well; no buildup after ~10 min. I then opened the bleeder on my pressure gauge to a balloon; no inflation, indicating no measurable flow of gas at this time. Although there is not a measurable flow of gas to warrant a violation at this time I am recommending the operator let the well open to allow any residual gas that may have been trapped between surface plug and marker cap to escape and to make sure t
2539821 Primary Facility 2016-11-29 Plugging(Includes Plugged/Mined Through) No Violations Noted Inspection of SWN’s Shively Sorenson 2H in Lenox Twp. Susquehanna County conducted November 29, 2016 at 12:00 pm. At the time of inspection; the 2” valve and needle valve coming off the marker cap were open, having been vented since my last site visit 11/21 per my recommendation to the operator. I removed the needle valve and threaded ½” pex fitting w/hose attached to Altair 5x gas meter. A field reading with the gas meter yielded no gas detectable in any amount at this time. I gave the operator the go ahead to shut in and bury the well. No violations noted.
2558463 Primary Facility 2017-02-01 Plugging(Includes Plugged/Mined Through) No Violations Noted Routine inspection of a plugged well. The well was plugged ~3 months ago. The below-ground marker is now buried in the cellar with gravel. The location was snow covered and there were no obvious concerns noted on the surface.
2852643 Primary Facility 2019-03-08 Plugging(Includes Plugged/Mined Through) No Violations Noted A routine, post-plugging inspection of this plugged unconventional well was conducted March 8, 2019. At the time of inspection, the site is reclaimed and the plugged well is now cut and buried below grade. The location was snow-covered. I stood at the buried well location; there were no open holes, discharges, venting, staining, bubbling, or other obvious issues observed at this time.

For data sources see[9]