If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-20873 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.813431,"lon":-75.955286,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Jessup Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145316 | |
Farm/Lease Name: HENNINGER 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-03-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.813431 | |
Longitude: -75.955286 |
Date | Event |
---|---|
2012-03-20 | New Permit Application |
2012-04-03 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-01-04 | 2013-02-02 | 6,163 | 5,910,200 | 336,400 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | CI-14 | Baker Hughes | Corrosion Inhibitor | Olefin | Trade Secret | 5 | 0.00002570 | 14.5 |
Polyoxyalkylenes | Trade Secret | 30 | 0.0001545 | 87 | ||||
Propargyl Alcohol | 107-19-7 | 5 | 0.00002570 | 14.5 | ||||
Fatty Acids | Trade Secret | 10 | 0.00005150 | 29 | ||||
Alpha 1427 | Baker Hughes | Biocide | Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 10 | 0.0022637 | 1274.88 | |
Glutaraldehyde | 111-30-8 | 30 | 0.0067912 | 3824.63 | ||||
Ethanol | 64-17-5 | 5 | 0.0011319 | 637.438 | ||||
Quaternary Ammonium Compound | 68424-85-1 | 5 | 0.0011319 | 637.438 | ||||
Sand, White, 100 mesh | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 0.808282 | 455200 | |
Sand, White, 30/50 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 6.32193 | 3,560,320.0 | |
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 87.5012 | 49,278,000.0 | |
HCl, 10.1 - 15% | Baker Hughes | Acidizing | Water | 7732-18-5 | 85 | 0.233459 | 131477 | |
Hydrochloric Acid | 7647-01-0 | 15 | 0.0411987 | 23201.9 | ||||
HCl, 5.1 - 7.5% | Baker Hughes | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.0102997 | 5800.47 | |
Water | 7732-18-5 | 92.5 | 0.127029 | 71539.1 | ||||
Other Chemicals | Formaldehyde | 50-00-0 | 0 | 0.00000510 | 2.9 | |||
Hydrochloric Acid | 7647-01-0 | 0 | 0.00000510 | 2.9 | ||||
Potassium Chloride | 7447-40-7 | 0 | 0.00000750 | 4.2069 | ||||
Poly (acrylamide-co-acrylic acid) | Trade Secret | 0 | 0.0271123 | 15268.8 | ||||
Ethoxylated Alcohol | Trade Secret | 0 | 0.0018075 | 1017.92 | ||||
Methanol | 67-56-1 | 0 | 0.0005149 | 290 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0.00000450 | 2.5242 | ||||
Sorbitan Monooleate | Trade Secret | 0 | 0.0045187 | 2544.81 | ||||
Modified Thiorea Polymer | 68527-49-1 | 0 | 0.00003600 | 20.3 | ||||
Water | 7732-18-5 | 0 | 0.067555 | 38044.9 | ||||
Salt | Trade Secret | 0 | 0.0045187 | 2544.81 | ||||
Polyacrylate | Trade Secret | 0 | 0.002988 | 1682.77 | ||||
Ferrotrol 300L | Baker Hughes | Iron Control | Citric Acid | 77-92-9 | 60 | 0.0013433 | 756.521 | |
Sand, White, 40/70 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 4.8016 | 2,704,120.0 | |
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Calcium Chloride | 10043-52-4 | 5 | 0.000747 | 420.692 | |
Ethylene Glycol | 107-21-1 | 30 | 0.004482 | 2524.15 | ||||
FRW-18 | Baker Hughes | Friction Reducer | Petroleum Distillates | 64742-47-8 | 30 | 0.0271123 | 15268.8 | |
InFlo 250W | Baker Hughes | Surfactant | Surfactants | Trade Secret | 80 | 0.0004738 | 266.81 | |
Methanol | 67-56-1 | 30 | 0.0001777 | 100.054 | ||||
2-Butoxyethanol | 111-76-2 | 5 | 0.00002960 | 16.6756 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 997,428.00 | 309 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 1,099,439.85 | 356 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 731,046.55 | 271 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 445,193.08 | 160 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 756,436.94 | 330 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 626,592.79 | 358 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 640,708.32 | 357 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 1,483.86 Tons | LANDFILL | 301626 |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 16,061.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 2,293.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 187.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 147.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 6,098.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 7,626.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 138.89 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 303.38 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 153.61 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 388.77 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 1,175.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 72.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 33.30 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 142.86 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 267.92 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 23.96 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 72.66 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 107.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 376.37 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 82.16 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 161.06 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 0.79 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | BKV OPR LLC | Produced Fluid | 65.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 70.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 649.01 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 73.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | BKV OPR LLC | Produced Fluid | 35.00 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Synthetic Liner Materials | 1.39 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Produced Fluid | 1,144.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2066928 | Primary Facility | 2012-05-09 | Drilling/Alteration | No Violations Noted | At time of inspection crews on site laying down secondary containment and off loading matting. Four conductors are set 1,2,3,4. Site ID sign posted with with permit # and site ID information. No violatons observed. |
2077217 | Primary Facility | 2012-06-18 | Drilling/Alteration | Violation(s) Noted | NE Rig 11. Encountered hig water (1000 bbl/hr) while drilling surface section. Observed minor bubbling in 3H cellar. Intermittent...not sure what cause is at this point. Operator will investigate and monitor for gas. Walked site. Observed diesel spilled on containment near large storage tank. Nozzle was laying on pad - not in holster. Also observed drill soap spilled onto containment. Violations cited for not containing drilling fluids in a tank. Not all secondary containment is established at this point. Crews are working to get containment in place. I indicated to Co. Man that all containment should be in place prior to drilling. Also asked to increase free board in open half round being used by Fluid Tech. |
2077232 | Primary Facility | 2012-06-19 | Drilling/Alteration | No Violations Noted | Cemented Surface. did not get returns to surface. Estblished TOC at 90'. Planning on doing top job later this evening. Observed bubbling in two cellars on pad. 2H - has welded cap on conductor - steady stream of bubbles observed coming from below cap. 3H - water level above conductor. observed a belch of bubbles approximately every 15 seconds. Checked cellar of 4H - did not observed bubbling in this cellar (vision limited due to wooden mat over cellar). Did not see any bubbling in 1H cellar, could not inspect 13 3/8" annulus due to casing hanger. REquested Operator to investigate bubbling and monitor. Violations cited on 6/18 for two spills - and noted deficiencies in secondary containment. Crews are still on site working on containment in areas addressed during 6/18 inspection. o |
2085091 | Primary Facility | 2012-07-12 | Follow-up Inspection | Violation(s) Noted | On site to inspect condition of wells as part of water supply investigation. Well has been drilled to KOP. Intermediate set. On site with Eric Rooney (DEP Geologist). At time of inspection - both valves on top of well open to atmosphere. Audible blowing heard out of valves. CGI meter read 100% combustible gas. Workers rigging down equipment in area of well while it is venting. BAsed on our observation this is unsafe venting. Violation cited for unsafe venting when it creates a hazard to the public health and safety. At time of discovery I notified Operator of situation. Operator was unaware and indicated a proper vent line will be installed immediately. |
2085108 | Primary Facility | 2012-07-16 | Follow-up Inspection | No Violations Noted | Follow up on venting of well. Cited violation for unsafe venting on 7/12/12. Well is now vented safely. Installed 2" flow line to hot box and flare stack on edge of containment. Met with representative from Carrizo at time of inspection. Planning on installing Barton chart recorder on well and monitor pressure. Also plan on collecting gas samples for isotopic analysis. DEP will collect gas samples from well also. Violation has been corrected at this time. |
2085258 | Primary Facility | 2012-07-20 | Follow-up Inspection | Pending | On site to collect gas samples and inspect condition of well. Met Eric Rooney(DEP geologist) and Doug S. of Carrizo on site at 10 am. Currently have 2" vent line with chart recorder on 9 5/8". Chart recorder reading @ 1psi and 100 lb gauge not showing any pressure. DEP collected two (2) gas samples from needle valve near chart recorder. Observed bubbling in cellar. Bubbling is coming from 2" port which is venting 9 x 13" annulus. Detected @2% conbustible gas from this port. While on site vac trucks pumped out water from all four cellars which were full from recent rains. Observed some bubbling in cellar of 2H. No other bubbling observed on site. 1H (9 5/8") is currently vented to flare stack. Can see visible vapors on flare stack. Well was shut in for @ 10 mins at one point and saw increase in pressure to 20 lbs in that time according to operator. Mr. Weller of Carrizo indicated later in the day that they are going to be loading the hole with SOBM to reduce/kill gas flow in the next couple of days. In the meantime will continue vent. |
2105650 | Primary Facility | 2012-09-24 | Follow-up Inspection | No Violations Noted | On site to collect isotopic gas samples from 13 3/8" x 9 5/8" annulus. At time of arrival annulus was shut it with 100 lb gauge. Reading was @ 4lbs. Eric Rooney on site at 9 am. Collected isotopic samples...when opened up needle valve...pressure quickly dissipated to 0psi with very little gas venting. Methane reading was collected from isotopic bag...reading was 2% using gas meter. |
2162283 | Primary Facility | 2013-04-24 | Routine/Complete Inspection | No Violations Noted | |
2164801 | Primary Facility | 2013-05-02 | Routine/Partial Inspection | No Violations Noted | Related to Mazzara Incident: 2162665 |
2365495 | Primary Facility | 2015-04-29 | Routine/Complete Inspection | No Violations Noted | |
2454159 | Primary Facility | 2016-02-29 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:35 p.m., the cellar had water at the bottom, the (13x9) vent pipe was open with a 100psi gauge on it that was reading 0psi with no gas detected, the (9x5) vent pipe was open with a 100psi gauge on it that was reading about 36psi and the valve going to the tank was closed, there was 1152psi on the production casing and 10psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 13:20 p.m. |
2544390 | Primary Facility | 2016-10-13 | Site Restoration | No Violations Noted | The Department was on site to inspect the Well Pad, ESX11-115-0138. The wells associated with the pad are as follows:
115-20873 115-20874 115-20875 115-20876 The site met the 70% vegetative standard, with decent growth everywhere on site. Recently constructed PCSM basins well constructed and well vegetated. No temp. BMPs on site. The vegetation was healthy and the site was stable. There were no erosional issues at this time. I recommend APPROVAL of this Notice of Termination. There were no violations. If there are any issues please feel free to contact me. |
2544895 | Primary Facility | 2016-12-13 | Routine/Complete Inspection | Pending | At time of inspection, arrived on site at 10:45a.m., the cellar was about three quarters full of water with no bubbling noticed, the (13x9) annulus was open and set up with a 100psi pressure gauge with 0psi on it, the (9x5) vent pipe was open and venting into the production tank. There was 750psi on the production casing and 458psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
After further review, in 2012 the well was part of a gas migration issue. The inspection results was pending on an inspection report 7/20/12 (2085258). I will contact Carrizo to set up a follow up inspection so the (13x9) vents can be checked for gas. I left the site at 11:25a.m. |
2545853 | Primary Facility | 2016-12-15 | Follow-up Inspection | No Violations Noted | At time of inspection, arrived on site at 13:15p.m., for a follow up inspection to check the (13x9) annulus for gas show. I was accompanied by Jon Sassi (DEP Environmental Specialist). We met with Joe Fowler from Carrizo, Joe closed the ball valve on the (13x9) annulus vent pipe before removing the pressure gauge. He then opened the valve while I used an Altair 5X gas meter to check for the presence of gas, there was no gas detected when the valve was opened. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 13:45p.m. |
2632984 | Primary Facility | 2017-09-05 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. I took a walk around the location and there were no obvious concerns noticed. |
2741127 | Primary Facility | 2018-06-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 2' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2836375 | Primary Facility | 2019-02-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water and ice 1' below grade in the cellar and there was no bubbling noticed. The (13x9) annulus was shut in with a 100psi pressure gauge with 0psi on it. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2077217 | 642179 | 06/18/2012 | 2012-06-18 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | |
2085091 | 644586 | 07/12/2012 | 2012-07-12 | 78.74* - Hazardous well venting | Environmental Health & Safety |
For data sources see[8]