37-115-20873

Well Details

Well ID: 37-115-20873
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jessup Township
Operator Name: BKV OPR LLC
Well Pad ID: 145316
Farm/Lease Name: HENNINGER 1H
License Status:
Spud Date:
Permit Date: 2012-03-20
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.813431
Longitude: -75.955286

For data sources see[1][2][3]

Well History

Date Event
2012-03-20 New Permit Application
2012-04-03 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-01-04 2013-02-02 6,163 5,910,200 336,400

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 CI-14 Baker Hughes Corrosion Inhibitor Olefin Trade Secret 5 0.00002570 14.5
Polyoxyalkylenes Trade Secret 30 0.0001545 87
Propargyl Alcohol 107-19-7 5 0.00002570 14.5
Fatty Acids Trade Secret 10 0.00005150 29
Alpha 1427 Baker Hughes Biocide Didecyl Dimethyl Ammonium Chloride 7173-51-5 10 0.0022637 1274.88
Glutaraldehyde 111-30-8 30 0.0067912 3824.63
Ethanol 64-17-5 5 0.0011319 637.438
Quaternary Ammonium Compound 68424-85-1 5 0.0011319 637.438
Sand, White, 100 mesh Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 0.808282 455200
Sand, White, 30/50 Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 6.32193 3,560,320.0
Water Operator Carrier Water 7732-18-5 100 87.5012 49,278,000.0
HCl, 10.1 - 15% Baker Hughes Acidizing Water 7732-18-5 85 0.233459 131477
Hydrochloric Acid 7647-01-0 15 0.0411987 23201.9
HCl, 5.1 - 7.5% Baker Hughes Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0102997 5800.47
Water 7732-18-5 92.5 0.127029 71539.1
Other Chemicals Formaldehyde 50-00-0 0 0.00000510 2.9
Hydrochloric Acid 7647-01-0 0 0.00000510 2.9
Potassium Chloride 7447-40-7 0 0.00000750 4.2069
Poly (acrylamide-co-acrylic acid) Trade Secret 0 0.0271123 15268.8
Ethoxylated Alcohol Trade Secret 0 0.0018075 1017.92
Methanol 67-56-1 0 0.0005149 290
Sodium Chloride 7647-14-5 0 0.00000450 2.5242
Sorbitan Monooleate Trade Secret 0 0.0045187 2544.81
Modified Thiorea Polymer 68527-49-1 0 0.00003600 20.3
Water 7732-18-5 0 0.067555 38044.9
Salt Trade Secret 0 0.0045187 2544.81
Polyacrylate Trade Secret 0 0.002988 1682.77
Ferrotrol 300L Baker Hughes Iron Control Citric Acid 77-92-9 60 0.0013433 756.521
Sand, White, 40/70 Baker Hughes Proppant Crystalline Silica (Quartz) 14808-60-7 100 4.8016 2,704,120.0
Scaletrol 720 Baker Hughes Scale Inhibitor Calcium Chloride 10043-52-4 5 0.000747 420.692
Ethylene Glycol 107-21-1 30 0.004482 2524.15
FRW-18 Baker Hughes Friction Reducer Petroleum Distillates 64742-47-8 30 0.0271123 15268.8
InFlo 250W Baker Hughes Surfactant Surfactants Trade Secret 80 0.0004738 266.81
Methanol 67-56-1 30 0.0001777 100.054
2-Butoxyethanol 111-76-2 5 0.00002960 16.6756

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 CARRIZO (MARCELLUS) LLC 0.00 0 0.00 0 0.00 0
2013 CARRIZO (MARCELLUS) LLC 997,428.00 309 0.00 0 0.00 0
2014 CARRIZO (MARCELLUS) LLC 1,099,439.85 356 0.00 0 0.00 0
2015 CARRIZO (MARCELLUS) LLC 731,046.55 271 0.00 0 0.00 0
2016 CARRIZO (MARCELLUS) LLC 445,193.08 160 0.00 0 0.00 0
2017 CARRIZO (MARCELLUS) LLC 756,436.94 330 0.00 0 0.00 0
2018 BKV OPR LLC 626,592.79 358 0.00 0 0.00 0
2019 BKV OPR LLC 640,708.32 357 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CARRIZO (MARCELLUS) LLC Drill Cuttings 1,483.86 Tons LANDFILL 301626
2013 CARRIZO (MARCELLUS) LLC Produced Fluid 16,061.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CARRIZO (MARCELLUS) LLC Produced Fluid 2,293.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 187.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 147.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 6,098.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2014 CARRIZO (MARCELLUS) LLC Produced Fluid 7,626.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 138.89 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 303.38 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 153.61 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 388.77 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2015 CARRIZO (MARCELLUS) LLC Produced Fluid 1,175.83 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CARRIZO (MARCELLUS) LLC Other Oil & Gas Wastes 16.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC018
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 72.74 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 33.30 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 142.86 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 267.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 23.96 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC010
2016 CARRIZO (MARCELLUS) LLC Other Oil & Gas Wastes 16.67 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE003
2016 CARRIZO (MARCELLUS) LLC Produced Fluid 72.66 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 107.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 376.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 82.16 Bbl REUSE (AT WELL PAD)
2017 CARRIZO (MARCELLUS) LLC Produced Fluid 161.06 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2017 CARRIZO (MARCELLUS) LLC Other Oil & Gas Wastes 0.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2018 BKV OPR LLC Produced Fluid 65.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2018 CARRIZO (MARCELLUS) LLC Produced Fluid 70.00 Bbl REUSE (AT WELL PAD)
2018 CARRIZO (MARCELLUS) LLC Produced Fluid 649.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 BKV OPR LLC Produced Fluid 73.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR119
2019 BKV OPR LLC Produced Fluid 35.00 Bbl REUSE (AT WELL PAD)
2019 BKV OPR LLC Produced Fluid 140.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE003
2019 BKV OPR LLC Synthetic Liner Materials 1.39 Tons RESIDUAL WASTE TRANSFER FACILITY 101714
2019 BKV OPR LLC Produced Fluid 1,144.14 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2066928 Primary Facility 2012-05-09 Drilling/Alteration No Violations Noted At time of inspection crews on site laying down secondary containment and off loading matting. Four conductors are set 1,2,3,4. Site ID sign posted with with permit # and site ID information. No violatons observed.
2077217 Primary Facility 2012-06-18 Drilling/Alteration Violation(s) Noted NE Rig 11. Encountered hig water (1000 bbl/hr) while drilling surface section. Observed minor bubbling in 3H cellar. Intermittent...not sure what cause is at this point. Operator will investigate and monitor for gas. Walked site. Observed diesel spilled on containment near large storage tank. Nozzle was laying on pad - not in holster. Also observed drill soap spilled onto containment. Violations cited for not containing drilling fluids in a tank. Not all secondary containment is established at this point. Crews are working to get containment in place. I indicated to Co. Man that all containment should be in place prior to drilling. Also asked to increase free board in open half round being used by Fluid Tech.
2077232 Primary Facility 2012-06-19 Drilling/Alteration No Violations Noted Cemented Surface. did not get returns to surface. Estblished TOC at 90'. Planning on doing top job later this evening. Observed bubbling in two cellars on pad. 2H - has welded cap on conductor - steady stream of bubbles observed coming from below cap. 3H - water level above conductor. observed a belch of bubbles approximately every 15 seconds. Checked cellar of 4H - did not observed bubbling in this cellar (vision limited due to wooden mat over cellar). Did not see any bubbling in 1H cellar, could not inspect 13 3/8" annulus due to casing hanger. REquested Operator to investigate bubbling and monitor. Violations cited on 6/18 for two spills - and noted deficiencies in secondary containment. Crews are still on site working on containment in areas addressed during 6/18 inspection. o
2085091 Primary Facility 2012-07-12 Follow-up Inspection Violation(s) Noted On site to inspect condition of wells as part of water supply investigation. Well has been drilled to KOP. Intermediate set. On site with Eric Rooney (DEP Geologist). At time of inspection - both valves on top of well open to atmosphere. Audible blowing heard out of valves. CGI meter read 100% combustible gas. Workers rigging down equipment in area of well while it is venting. BAsed on our observation this is unsafe venting. Violation cited for unsafe venting when it creates a hazard to the public health and safety. At time of discovery I notified Operator of situation. Operator was unaware and indicated a proper vent line will be installed immediately.
2085108 Primary Facility 2012-07-16 Follow-up Inspection No Violations Noted Follow up on venting of well. Cited violation for unsafe venting on 7/12/12. Well is now vented safely. Installed 2" flow line to hot box and flare stack on edge of containment. Met with representative from Carrizo at time of inspection. Planning on installing Barton chart recorder on well and monitor pressure. Also plan on collecting gas samples for isotopic analysis. DEP will collect gas samples from well also. Violation has been corrected at this time.
2085258 Primary Facility 2012-07-20 Follow-up Inspection Pending On site to collect gas samples and inspect condition of well. Met Eric Rooney(DEP geologist) and Doug S. of Carrizo on site at 10 am. Currently have 2" vent line with chart recorder on 9 5/8". Chart recorder reading @ 1psi and 100 lb gauge not showing any pressure. DEP collected two (2) gas samples from needle valve near chart recorder. Observed bubbling in cellar. Bubbling is coming from 2" port which is venting 9 x 13" annulus. Detected @2% conbustible gas from this port. While on site vac trucks pumped out water from all four cellars which were full from recent rains. Observed some bubbling in cellar of 2H. No other bubbling observed on site. 1H (9 5/8") is currently vented to flare stack. Can see visible vapors on flare stack. Well was shut in for @ 10 mins at one point and saw increase in pressure to 20 lbs in that time according to operator. Mr. Weller of Carrizo indicated later in the day that they are going to be loading the hole with SOBM to reduce/kill gas flow in the next couple of days. In the meantime will continue vent.
2105650 Primary Facility 2012-09-24 Follow-up Inspection No Violations Noted On site to collect isotopic gas samples from 13 3/8" x 9 5/8" annulus. At time of arrival annulus was shut it with 100 lb gauge. Reading was @ 4lbs. Eric Rooney on site at 9 am. Collected isotopic samples...when opened up needle valve...pressure quickly dissipated to 0psi with very little gas venting. Methane reading was collected from isotopic bag...reading was 2% using gas meter.
2162283 Primary Facility 2013-04-24 Routine/Complete Inspection No Violations Noted
2164801 Primary Facility 2013-05-02 Routine/Partial Inspection No Violations Noted Related to Mazzara Incident: 2162665
2365495 Primary Facility 2015-04-29 Routine/Complete Inspection No Violations Noted
2454159 Primary Facility 2016-02-29 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:35 p.m., the cellar had water at the bottom, the (13x9) vent pipe was open with a 100psi gauge on it that was reading 0psi with no gas detected, the (9x5) vent pipe was open with a 100psi gauge on it that was reading about 36psi and the valve going to the tank was closed, there was 1152psi on the production casing and 10psi on the production line. I took a walk around the location and everything looked OK.

I left the site at 13:20 p.m.

2544390 Primary Facility 2016-10-13 Site Restoration No Violations Noted The Department was on site to inspect the Well Pad, ESX11-115-0138. The wells associated with the pad are as follows:

115-20873 115-20874 115-20875 115-20876

The site met the 70% vegetative standard, with decent growth everywhere on site. Recently constructed PCSM basins well constructed and well vegetated. No temp. BMPs on site. The vegetation was healthy and the site was stable. There were no erosional issues at this time.

I recommend APPROVAL of this Notice of Termination.

There were no violations.

If there are any issues please feel free to contact me.

2544895 Primary Facility 2016-12-13 Routine/Complete Inspection Pending At time of inspection, arrived on site at 10:45a.m., the cellar was about three quarters full of water with no bubbling noticed, the (13x9) annulus was open and set up with a 100psi pressure gauge with 0psi on it, the (9x5) vent pipe was open and venting into the production tank. There was 750psi on the production casing and 458psi on the production line. I took a walk around the location and there were no obvious concerns noticed.

After further review, in 2012 the well was part of a gas migration issue. The inspection results was pending on an inspection report 7/20/12 (2085258). I will contact Carrizo to set up a follow up inspection so the (13x9) vents can be checked for gas. I left the site at 11:25a.m.

2545853 Primary Facility 2016-12-15 Follow-up Inspection No Violations Noted At time of inspection, arrived on site at 13:15p.m., for a follow up inspection to check the (13x9) annulus for gas show. I was accompanied by Jon Sassi (DEP Environmental Specialist). We met with Joe Fowler from Carrizo, Joe closed the ball valve on the (13x9) annulus vent pipe before removing the pressure gauge. He then opened the valve while I used an Altair 5X gas meter to check for the presence of gas, there was no gas detected when the valve was opened. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 13:45p.m.

2632984 Primary Facility 2017-09-05 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. I took a walk around the location and there were no obvious concerns noticed.

2741127 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 2' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2836375 Primary Facility 2019-02-06 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water and ice 1' below grade in the cellar and there was no bubbling noticed. The (13x9) annulus was shut in with a 100psi pressure gauge with 0psi on it. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2077217 642179 06/18/2012 2012-06-18 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. Administrative
2085091 644586 07/12/2012 2012-07-12 78.74* - Hazardous well venting Environmental Health & Safety

For data sources see[8]

References