Well ID: 37-115-20874 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.813428,"lon":-75.955231,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Jessup Township | |
Operator Name: BKV OPR LLC | |
Well Pad ID: 145316 | |
Farm/Lease Name: HENNINGER 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2012-03-20 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.813428 | |
Longitude: -75.955231 |
Date | Event |
---|---|
2012-03-20 | New Permit Application |
2012-04-09 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-01-05 | 2013-02-03 | 6,151 | 5,940,730 | 338,697 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand, White, 100 mesh | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 0.801227 | 453770 |
Ferrotrol 300L | Baker Hughes | Iron Control | Citric Acid | 77-92-9 | 60 | 0.001269 | 718.694 | |
Sand, White, 40/70 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 4.76869 | 2,700,720.0 | |
Alpha 1427 | Baker Hughes | Biocide | Quaternary Ammonium Compound | 68424-85-1 | 5 | 0.0011533 | 653.188 | |
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 10 | 0.0023067 | 1306.38 | ||||
Ethanol | 64-17-5 | 5 | 0.0011533 | 653.188 | ||||
Glutaraldehyde | 111-30-8 | 30 | 0.00692 | 3919.13 | ||||
HCl, 10.1 - 15% | Baker Hughes | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0384073 | 21751.8 | |
Water | 7732-18-5 | 85 | 0.217641 | 123260 | ||||
Sand, White, 30/50 | Baker Hughes | Proppant | Crystalline Silica (Quartz) | 14808-60-7 | 100 | 6.4226 | 3,637,400.0 | |
Scaletrol 720 | Baker Hughes | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 30 | 0.0045463 | 2574.75 | |
Calcium Chloride | 10043-52-4 | 5 | 0.0007577 | 429.126 | ||||
InFlo 250W | Baker Hughes | Surfactant | Surfactants | Trade Secret | 80 | 0.0004476 | 253.469 | |
2-Butoxyethanol | 111-76-2 | 5 | 0.00002800 | 15.8418 | ||||
Methanol | 67-56-1 | 30 | 0.0001678 | 95.0509 | ||||
HCl, 5.1 - 7.5% | Baker Hughes | Acidizing | Hydrochloric Acid | 7647-01-0 | 7.5 | 0.010242 | 5800.47 | |
Water | 7732-18-5 | 92.5 | 0.126317 | 71539.1 | ||||
Other Chemicals | Methanol | 67-56-1 | 0 | 0.0004865 | 275.5 | |||
Modified Thiorea Polymer | 68527-49-1 | 0 | 0.00003410 | 19.285 | ||||
Potassium Chloride | 7447-40-7 | 0 | 0.00000760 | 4.2913 | ||||
Hydrochloric Acid | 7647-01-0 | 0 | 0.00000490 | 2.755 | ||||
Ethoxylated Alcohol | Trade Secret | 0 | 0.0017924 | 1015.09 | ||||
Salt | Trade Secret | 0 | 0.0044809 | 2537.74 | ||||
Formaldehyde | 50-00-0 | 0 | 0.00000490 | 2.755 | ||||
Sodium Chloride | 7647-14-5 | 0 | 0.00000450 | 2.5748 | ||||
Sorbitan Monooleate | Trade Secret | 0 | 0.0044809 | 2537.74 | ||||
Water | 7732-18-5 | 0 | 0.0674688 | 38210.5 | ||||
Polyacrylate | Trade Secret | 0 | 0.0030308 | 1716.5 | ||||
Poly (acrylamide-co-acrylic acid) | Trade Secret | 0 | 0.0268855 | 15226.4 | ||||
FRW-18 | Baker Hughes | Friction Reducer | Petroleum Distillates | 64742-47-8 | 30 | 0.0268855 | 15226.4 | |
Water | Operator | Carrier | Water | 7732-18-5 | 100 | 87.4603 | 49,532,600.0 | |
CI-14 | Baker Hughes | Corrosion Inhibitor | Fatty Acids | Trade Secret | 10 | 0.00004860 | 27.55 | |
Polyoxyalkylenes | Trade Secret | 30 | 0.0001459 | 82.65 | ||||
Olefin | Trade Secret | 5 | 0.00002430 | 13.775 | ||||
Propargyl Alcohol | 107-19-7 | 5 | 0.00002430 | 13.775 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CARRIZO (MARCELLUS) LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CARRIZO (MARCELLUS) LLC | 1,193,612.00 | 309 | 0.00 | 0 | 0.00 | 0 |
2014 | CARRIZO (MARCELLUS) LLC | 1,191,736.49 | 354 | 0.00 | 0 | 0.00 | 0 |
2015 | CARRIZO (MARCELLUS) LLC | 551,866.82 | 212 | 0.00 | 0 | 0.00 | 0 |
2016 | CARRIZO (MARCELLUS) LLC | 526,282.76 | 178 | 0.00 | 0 | 0.00 | 0 |
2017 | CARRIZO (MARCELLUS) LLC | 862,832.78 | 355 | 0.00 | 0 | 0.00 | 0 |
2018 | BKV OPR LLC | 652,188.25 | 362 | 0.00 | 0 | 0.00 | 0 |
2019 | BKV OPR LLC | 693,476.05 | 358 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CARRIZO (MARCELLUS) LLC | Drill Cuttings | 1,116.58 Tons | LANDFILL | 301626 |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 15,710.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 2,278.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 187.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 147.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 6,098.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 7,626.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 132.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 212.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 141.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 239.66 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2015 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 646.12 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 72.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 34.12 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 173.48 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 355.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 93.09 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2016 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE003 |
2016 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 44.51 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 111.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 409.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 70.60 Bbl | REUSE (AT WELL PAD) | |
2017 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 237.53 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2017 | CARRIZO (MARCELLUS) LLC | Other Oil & Gas Wastes | 0.79 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | BKV OPR LLC | Produced Fluid | 65.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 72.45 Bbl | REUSE (AT WELL PAD) | |
2018 | CARRIZO (MARCELLUS) LLC | Produced Fluid | 657.72 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | BKV OPR LLC | Produced Fluid | 73.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | BKV OPR LLC | Produced Fluid | 35.00 Bbl | REUSE (AT WELL PAD) | |
2019 | BKV OPR LLC | Produced Fluid | 140.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE003 |
2019 | BKV OPR LLC | Synthetic Liner Materials | 1.39 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101714 |
2019 | BKV OPR LLC | Produced Fluid | 1,144.14 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2066925 | Primary Facility | 2012-05-09 | Drilling/Alteration | Violation(s) Noted | At time of inspection crews on site laying down felt as part of secondary containment and offloading matting. Four conductors set 1,2,3,4. Site ID sign does not have Permit # posted as required by 58 P.S 201(g) State Statute. |
2078831 | Primary Facility | 2012-06-21 | Follow-up Inspection | No Violations Noted | Steve Watson and Eric Rooney on site to follow up on bubbling in cellar of 2H and 3H. Operator informed DEP that bubbling had ceased. Operator filled cellar and conductor of 2H while on site. DEP monitored the cellar with Model 60, and Altair gas meters for presence of gas. No detections of gas were observed. No bubbling was observed at time of inspection. DEP asked Operator to notify DEP if bubbles occur while drilling surface section of 2H. While on site I re-inspected areas of pad where violations had prviously been cited. Mr. Gary Byron accompanied me. Secondary containment has been established in the area of the fuel oil tank, and in the drum storage area. All other areas where containment had not been previously established have been installed correctly. At this time no outstanding violations exist. |
2105671 | Primary Facility | 2012-09-24 | Follow-up Inspection | No Violations Noted | On site to grab isotopic gas sample. At time of arrival 9x13" annulus shut in w 100 lb gauge = reading was 42 lbs. Eric Rooney of DEP on site at 9 am to collect sample. Using Altair gas meter detected 100% methane from vent on 9 x 13" annulus. DEP grabbed isotopic gas sample. Operator left vent open upon completion of sampling. Moving Nabors Rig in on site and expect to be drilling later this week. |
2110112 | Primary Facility | 2012-10-10 | Drilling/Alteration | No Violations Noted | Nabors Rig M61. Resumed drilling - e notice recieved on 10/6/12. REsumed drilling on 10/7/12 @ 5570'. i walked site - secondary containment in place consisting of mats and plastic. Drilling ahead on SOBM at time of inspection. BOP charts posted. Site ID sign only had 3 permits posted. 4 wells have been spud. Opeartor must add 4th well permit to sign. Checked cellars - no evidence of bubbling at this time. No violations observed. |
2365491 | Primary Facility | 2015-04-29 | Routine/Complete Inspection | No Violations Noted | |
2454157 | Primary Facility | 2016-02-29 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 12:35 p.m., the cellar had water at the bottom, the (13x9) vent pipe was open and venting into the atmosphere with no gas detected, the (9x5) vent pipe was open and venting to a tank, there was 1299psi on the production casing and 477psi on the production line. I took a walk around the location and everything looked OK.
I left the site at 13:20 p.m. |
2544391 | Primary Facility | 2016-10-13 | Site Restoration | No Violations Noted | The Department was on site to inspect the Well Pad, ESX11-115-0138. The wells associated with the pad are as follows:
115-20873 115-20874 115-20875 115-20876 The site met the 70% vegetative standard, with decent growth everywhere on site. Recently constructed PCSM basins well constructed and well vegetated. No temp. BMPs on site. The vegetation was healthy and the site was stable. There were no erosional issues at this time. I recommend APPROVAL of this Notice of Termination. There were no violations. If there are any issues please feel free to contact me. |
2544896 | Primary Facility | 2016-12-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 10:45a.m., the cellar was about a quarter full of water with no bubbling noticed, the (13x9) annulus was open and set up with a 100psi pressure gauge with 0psi on it, the (9x5) vent pipe was open and venting into the production tank. There was 744psi on the production casing and 441psi on the production line. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 11:25a.m. |
2545856 | Primary Facility | 2016-12-15 | Follow-up Inspection | No Violations Noted | At time of inspection, arrived on site at 13:15p.m., for a follow up inspection to check the (13x9) annulus for gas show. I was accompanied by Jon Sassi (DEP Environmental Specialist). We met with Joe Fowler from Carrizo, Joe closed the ball valve on the (13x9) annulus vent pipe before removing the pressure gauge. He then opened the valve while I used an Altair 5X gas meter to check for the presence of gas, there was no gas detected when the valve was opened. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 13:45p.m. |
2632988 | Primary Facility | 2017-09-05 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. I took a walk around the location and there were no obvious concerns noticed. |
2741129 | Primary Facility | 2018-06-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 0' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2836379 | Primary Facility | 2019-02-06 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of water and there was no bubbling noticed. The (13x9) annulus was shut in with a 30psi pressure gauge with 0psi on it. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2066925 | 639087 | 05/09/2012 | 2012-05-09 | 201G - Failure to post permit number, operator name, address, telephone number in a conspicuous manner at the site during drilling | Administrative |