37-115-20971

Well Details

Well ID: 37-115-20971
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Silver Lake Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 149432
Farm/Lease Name: THOMAS CONATY SW 1 8H
License Status: Plugged and Abandoned
Spud Date:
Permit Date: 2012-09-11
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.986172
Longitude: -75.937278

For data sources see[1][2][3]

Well History

Date Event
2012-09-11 New Permit Application
2012-10-11 Performed Spud Operation
2016-05-02 Inactive Well Request Granted
2017-09-22 Begin Plugging
2017-09-30 Finished Plugging

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2013 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2014 XPR RESOURCES LLC 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2016 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2017 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 XPR RESOURCES LLC Drilling Fluid Waste 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC006
2012 XPR RESOURCES LLC Drill Cuttings 1,134.23 Tons LANDFILL 8-0728-0004/013
2012 XPR RESOURCES LLC Drill Cuttings 78.31 Tons LANDFILL NY # 02S17
2017 SWN PROD CO LLC Other Oil & Gas Wastes 272.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Servicing Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SWN PROD CO LLC Produced Fluid 80.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2129790 Primary Facility 2013-01-03 Routine/Complete Inspection No Violations Noted Routine insepction of site. ID sign in place with proper information. No activity on site. Pad covered in snow. Checked cellars (8H and 10H) Well shut in . No bubbling observed. Topholes drilled. No violations noted.
2343418 Primary Facility 2014-12-30 Routine/Partial Inspection No Violations Noted The Department was on site at the Thomas Conaty well site located at 600 Arrowhead Cottage Road Brackney, PA to conduct a Routine Partial Inspection. The E&S Inspection Log indicated that Will Slote conducted an inspection on 12/30/14 and that the site was ok and snow covered at the time. At the time of the inspection, the site was mostly snow covered. No obvious E&S issues were found.
2358393 Primary Facility 2015-04-06 Routine/Complete Inspection No Violations Noted
2378809 Primary Facility 2015-06-04 Routine/Complete Inspection No Violations Noted
2509071 Primary Facility 2016-08-09 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:45p.m., the well was given inactive status on 12/7/15. The cellar was full of water with no bubbling noticed; the vent pipe was open and set up with a Taylor plug to check for pressure, there was a cap on top of the well. There were no lines going to or from the well and there were no tanks or production units on the site. I took a walk around the location and everything looked OK.

I left the site at 13:05p.m.

2602053 Primary Facility 2017-06-07 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 9:45a.m.

The well was drilled to TD at 11,876' but wasn’t stimulated and granted inactive status on 12/7/15. The cellar was full of water with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge. There was a TA cap on top of the well with a Taylor plug to check for pressure with a Crystal pressure gauge. There are no lines going to or from the well and there are no tanks or production units on site. I took a walk around the location and there were no obvious concerns noticed. I left the site at 10:10a.m.

2607887 Primary Facility 2017-06-27 Routine/Complete Inspection No Violations Noted I inspected this site on June 1, 2017. The site was generally stable, although there are weak spots of vegetation, especially along the access road. (See photos). One area in particular along the access road is recommended to be reseeded and stabilized as soon as possible, as the vegetation is gone and the ground is in danger of eroding. The pad surface was stable and solid, with the area around the well heads appearing to have been cemented. The cut and fill slopes were generally in good shape, although the vegetation on the cut slope was struggling a bit due to rocky soil conditions. The access road itself seemed solid and stable.

There were no violations observed during this inspection.

2629954 Primary Facility 2017-08-28 Routine/Complete Inspection No Violations Noted Well is shut in; night cap on production casing spool. Backside of csg shut in on taylor plug valve. Cellar full of water, no observable issues. Operator has submitted notice of intent to plug, nobody on location
2638904 Primary Facility 2017-09-22 Plugging(Includes Plugged/Mined Through) No Violations Noted Rig on location for P&A. Wireline rigged up to set CIBP in 5 1/2" in both wells to isolate Marcellus. No pressure; well was never perf'd. The operator will cap both CIBPs w/ CMT, gel uphole, and set cmt plugs across intermediate an surface csg shoes (inside production csg). CBLs indicate production casing unrecoverable. Walked the location with the Companyman. There were no issues observed.
2666011 Primary Facility 2017-11-29 Administrative/File Review No Violations Noted November 30, 2017: Certificate of Well Plugging for the Thomas Conaty 8H (115-20971) has been received, reviewed, signed, and sent to file.

For data sources see[7]

References