X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21306

Well Details

Well ID: 37-115-21306
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 149723
Farm/Lease Name: PAYNE D 8
License Status:
Spud Date:
Permit Date: 2013-06-21
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.772064
Longitude: -75.676069

For data sources see[1][2][3]

Well History

Date Event
2013-06-21 New Permit Application
2013-08-27 Performed Spud Operation
2013-12-16 Drilling Completion
2014-01-12 Perforation
2014-02-05 Performed Stimulation
2014-05-01 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-02-04 2014-02-17 7,099 9,577,720 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 100 Mesh Sand FTSI proppant Silica, Quartz 14808-60-7 100 0.581338 525500
Hydrochloric Acid (HCl) FTSI Acid Water 7732-18-5 85 0.449008 405880
Hydrogen Chloride 7647-01-0 15 0.0792367 71625.9
BIO-3240 FTSI Biocide Water 7732-18-5 55 0.016704 15099.5
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione.
533-74-4 24 0.00728901 6588.89
Sodium Hydroxide 1310-73-2 23 0.0069853 6314.36
40/70 White FTSI proppant Silica, Quartz 14808-60-7 100 10.3743 9,377,800.0
FRW-200 FTSI Friction reducer Polyethylene glycol monooleate 9004-96-0 3 0.00261931 2367.72
Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.000873104 789.24
Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.00349242 3156.97
Acrylamide 79-06-1 0.1 0.00008731 78.92
Water 7732-18-5 48 0.041909 37883.6
Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.00349242 3156.97
Hydrotreated heavy paraffinic 64742-54-7 5 0.00436552 3946.21
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.00349242 3156.97
Sorbitan Monooleate 1338-43-8 3 0.00261931 2367.72
Ammonium Chloride 12125-02-9 12 0.0104772 9470.9
Dewaxed heavy paraffinic 64742-65-0 1.5 0.00130966 1183.86
Surfactant Proprietary 7 0.00611173 5524.69
Petroleum distillate hydrotreated light 64742-47-8 26 0.0227007 20520.3
Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.0218276 19731
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.0288124 26045
Sorbitol Tetraoleate 61723-83-9 2 0.00174621 1578.48
Isopropanol 67-63-0 0.3 0.000261931 236.77
Ammonium Acrylate 10604-69-0 0.5 0.000436552 394.62
CI-150 FTSI Acid Corrosion Inhibitor Quaternary ammonium compound Proprietary 10 0.00009343 84.46
Water 7732-18-5 5 0.00004672 42.23
Organic amine resin salt Proprietary 30 0.000280303 253.38
Aliphatic alcohol Proprietary 0.1 0.00000093 0.84
Fatty Acid Proprietary 0.1 0.00000093 0.84
Isopropanol 67-63-0 30 0.000280303 253.38
Ethylene Glycol 107-21-1 30 0.000280303 253.38
Dimethylformamide 68-12-2 10 0.00009343 84.46
Diethylene glycol 111-46-6 1 0.00000934 8.45
Alkylene Oxide Block Polymer Proprietary 10 0.00009343 84.46
Aromatic aldehyde Proprietary 10 0.00009343 84.46
Fatty Acid Salt Proprietary 0.1 0.00000093 0.84
FE-100L FTSI Iron control Water 7732-18-5 60 0.00100378 907.37
Citric acid 77-92-9 55 0.000920134 831.75
Water Operator Carrier Water 7732-18-5 100 88.3658 79,878,200.0
CS-500 SI FTSI Scale inhibitor Sodium Polyacrylate 9003-04-7 5 0.00150231 1358.01
Sodium chloride 7647-14-5 6 0.00180277 1629.61
Acrylic Polymer Proprietary 0 0 0
Ethylene glycol 107-21-1 10 0.00300462 2716.02
Water 7732-18-5 55 0.0165254 14938.1

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-02-05 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 4,000,979.19 295 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 2,713,447.14 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 1,701,831.00 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 1,085,049.78 364 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 665,778.00 210 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 624,561.00 166 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 1,513.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 1,495.12 Tons LANDFILL 101247
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 57.33 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 106.53 Tons LANDFILL THR029
2014 CABOT OIL & GAS CORP Produced Fluid 9,400.76 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 248.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 13,835.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 2,183.53 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 16.15 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 515.75 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 226.39 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 67.45 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 126.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 102.40 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2018 CABOT OIL & GAS CORP Produced Fluid 91.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Waste Water Treatment Sludge 1.14 Tons REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 8.12 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 0.89 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Produced Fluid 138.76 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 375.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 769.56 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2198443 Primary Facility 2013-08-26 Routine/Complete Inspection No Violations Noted The Department was on site at the Cabot Payne, D. P1 Well Site to conduct a Preoperational Inspection on 8/26/13. Well permits that have been issued for this pad are the 2H (115-21305), 3H (115-21304), and the 8H (115-21306). All perimeter BMP’s in place. Pad is approximately 98% complete. Site has been constructed as per plan. No violations noted.
2227392 Primary Facility 2013-12-04 Drilling/Alteration No Violations Noted drilling at 3340
2227876 Primary Facility 2013-12-10 Drilling/Alteration No Violations Noted drilling at 12565 approx 350' off bottom motor failure
2246008 Primary Facility 2014-02-12 Drilling/Alteration No Violations Noted
2407904 Primary Facility 2015-09-16 Routine/Complete Inspection No Violations Noted The Department was on site to conduct an E&S inspection of the Payne Well Pad in Harford Twp. The pad was in good shape, no erosional issues were apparent and the site was stable.
2472566 Primary Facility 2016-04-06 Routine/Complete Inspection No Violations Noted
2483833 Primary Facility 2016-05-13 Routine/Complete Inspection No Violations Noted
2497220 Primary Facility 2016-06-29 Routine/Complete Inspection No Violations Noted On 6/29/16, the Department was on site at the COG Payne D. Pad 1 to conduct a routine inspection. The pad has good permanent stabilization, with approximately 70% vegetative stabilization and 30% rock stabilization. Filter sock at the site could probably be removed at this point. All 3 wells on the pad, the 2H, 3H, and 8H appear to be in production. All 3 cellars ½ full of water with no bubbling observed. E & S inspections up-to-date. The Department highly recommends that the access road and associated ditches/culverts be cleaned and re-sculpted to maintain efficiency which is critical since the access road has a rather steep grade and sharp turn. Overall, the site looks good. No violations noted.
2554819 Primary Facility 2017-01-24 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:20p.m., the cellar had water and ice at the bottom with no bubbling noticed. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 574psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 12:55p.m.

2643082 Primary Facility 2017-10-03 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. All the annulus vent pipes were connected together and going to the same tank. There was containment near the 2H well and it appears tubing was recently put in the 2H. The containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2748224 Primary Facility 2018-07-03 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[9]

References