37-115-21330

Well Details

Well ID: 37-115-21330
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150517
Farm/Lease Name: CONKLIN NORTH 1H
License Status:
Spud Date:
Permit Date: 2013-06-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.830247
Longitude: -75.699825

For data sources see[1][2][3]

Well History

Date Event
2013-06-17 New Permit Application
2013-07-03 Performed Spud Operation
2013-10-29 Drilling Completion
2014-04-25 Perforation
2014-05-02 Performed Stimulation
2014-09-03 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-05-02 2014-05-06 6,615 7,773,360 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water SWN Water / Produced Water H2O + Disolved Salts 7732-18-5 100 90.091 106,085,000.0
K Bac -1020 WST Biocide Polyethylene glycol 25322-68-3 60 0.00443428 5221.5
2,2-Diobrom-3nirilopropionamide 10222-01-2 20 0.00147809 1740.5
15% HCl Reagent Acid HCL 7647-01-0 15 0.0729248 85871.2
Sand Keane Sand Crystalline Silica, Quartz 14808-60-7 100 9.35137 11,011,500.0
FRA-405 Clearwater Friction Reducer Ammonium Chloride 12125-02-9 7 0.00394726 4648.02
Sodium Chloride 7647-14-5 10 0.00563895 6640.03
Alcohols, C-12-16, Ethoxylated 68551-12-2 7 0.00394726 4648.02
Petroleum Distillates 64742-47-8 40 0.0225558 26560.1
EC6486 Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00193197 2274.95
AI-600 Weatherford Acid Inhibitor Isopropyl Alchol 67-63-0 7 0.00008508 100.183
Ethoxylated Nonylphenol 68412-54-4 10 0.000121541 143.119
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 13 0.000158004 186.054
Triethyl Phosphate 78-40-0 7 0.00008508 100.183
2-Butoxyethanol 111-76-2 7 0.00008508 100.183
Ethylene Glycol 107-21-1 60 0.000729248 858.712
Cinnamaldehyde 104-55-2 10 0.000121541 143.119
N,N-Dimethylformamide 68-12-2 40 0.000486166 572.475

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-05-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 1,749,720.00 216 0.00 0 0.00 0
2015 SWN PROD CO LLC 2,672,707.00 361 0.00 0 0.00 0
2016 SWN PROD CO LLC 2,000,207.00 352 0.00 0 0.00 0
2017 SWN PROD CO LLC 1,200,801.00 322 0.00 0 0.00 0
2018 SWN PROD CO LLC 983,318.00 330 0.00 0 0.00 0
2019 SWN PROD CO LLC 763,433.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,540.55 Tons LANDFILL 101247
2013 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 200.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 6,920.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 56.22 Tons LANDFILL THR029
2014 SOUTHWESTERN ENERGY PROD CO Produced Fluid 4,035.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Produced Fluid 2,582.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Other Oil & Gas Wastes 50.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Drill Cuttings 319.28 Tons LANDFILL 101247
2016 SWN PROD CO LLC Produced Fluid 1,845.80 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 192.60 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Synthetic Liner Materials 8.20 Tons LANDFILL 101247
2017 SWN PROD CO LLC Produced Fluid 4,759.10 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 4,365.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 646.80 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 161.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Unused Fracturing Fluid Waste 34.08 Tons LANDFILL 100933
2018 SWN PROD CO LLC Produced Fluid 1,268.80 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 277.13 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 68.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 864.40 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 54.23 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Soil Contaminated by Oil 0.23 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2019 SWN PROD CO LLC Produced Fluid 22.00 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 318.80 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.23 Tons RESIDUAL WASTE PROCESSING FACILITY 301333

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2219043 Primary Facility 2013-07-09 Drilling/Alteration No Violations Noted Crews on site riggin up, liner on location
2381034 Primary Facility 2015-06-22 Routine/Complete Inspection No Violations Noted
2454375 Primary Facility 2016-02-26 Routine/Complete Inspection No Violations Noted
2478922 Primary Facility 2016-04-27 Routine/Complete Inspection No Violations Noted
2488545 Primary Facility 2016-05-31 Routine/Complete Inspection No Violations Noted
2581104 Primary Facility 2017-04-10 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:55p.m.

The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 761psi on the production casing and 651psi on the production line. Halliburton was on site and logging the 2H, 3H, and 5H wells. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:45p.m.

2591757 Primary Facility 2017-05-09 Routine/Complete Inspection No Violations Noted Inspection conducted on May 4, 2017. Minor damage shown in photo 2 needs to be repaired. The road side ditch from 5+00 to 10+00 needs to be reestablished to design specifications. Photo 4 shows damage near entrance to pad. This damage needs to be repaired. Appears as if this location is a low point on the pad which is causing the damage. Please have your pad designers review to determine if controls should be added at this location, possibly a level spreader. Conklin North 1H and Conklin South 5H appear to be in production. Other three wells drilled are the North 2H, South 5H, and the North 3H. Photo 5 shows garbage that has been left on the pad. Please remove, before a storm event does.
2684967 Primary Facility 2018-01-08 Incident- Response to Accident or Event No Violations Noted Gene Rickard, DEP O&G WQS and I arrived at the site at 11:29 in response to a reported spill of (300-400) gallons of production fluid to secondary containment, with (2-3) barrels of the fluid spilled escaping the containment to the pad surface. The weather conditions were cloudy skies, cold and breezy with temperatures in the 20's. US well service is the SWN subcontractor at the site in the process of conducting hydraulic fracturing (stimulation) operations. Mike Deming, Senior Regulatory Analyst and Zachary Evans, well site supervisor/site company man, both of SWN, accompanied the Department during the inspection. Dawn Washo represented Resource Environmental of Montrose, PA. Mr. Deming and Mr. Evans provided the following details regarding the spill and site activities. "We are on stage 41 of 43 for the frac on the Conklin South 5H well. We are pressured up and perforating. The 3H is the next well to be completed. A total of (300) to (400) barrels of production fluid was spilled to containment. There were
2688035 Primary Facility 2018-01-23 Incident- Response to Accident or Event No Violations Noted Today's inspection was conducted as an incident inspection. At approximately noon today, Mike Deming, SWN Senior Regulatory Analyst contacted the Department to inform the Department that SWN had identified stormwater discharges off secondary containment on 3 of their well pads, of which this pad is one. The discharge from containment occurred when ice formed and collapsed the containment edge. Photo 2 shows the containment edge being reestablished. The Department conducted conductivity metering and found that outside containment conductivity ranged between 150 uS and 250 uS. Inside containment readings ranged from 165 uS to 250 uS. Work over rig on site drilling out plugs. Currenty in 3H. Of note is the fact that a production fluid spill had occurred on January 5, 2018 in the photo 3 vicinity. No E&S violations were observed. No violations noted.
2721904 Primary Facility 2018-04-23 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2722477 Primary Facility 2018-04-24 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. The battery of water tanks are still present and located on containment. All 5 wells appear to be in production. Photo 2 shows trash that needs to be removed. No violations noted.
2809441 Primary Facility 2018-12-03 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Good site stabilization. No E&S issues identified. No violations noted.
2821445 Primary Facility 2019-01-02 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was full of gravel and there was no gas detected at the perimeter of the cellar with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2841929 Primary Facility 2019-02-14 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. As the photo's show, the site is snow covered. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[9]