Well History

Date Event
2013-09-24 New Permit Application
2013-11-27 Performed Spud Operation
2014-03-05 Drilling Completion
2014-12-08 Perforation
2014-12-08 Performed Stimulation
2016-01-20 DEVIATED

For data sources see[4]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-12-08 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2014 SOUTHWESTERN ENERGY PROD CO 0.00 0 0.00 0 0.00 0
2015 SWN PROD CO LLC 1,774,001.00 316 0.00 0 0.00 0
2016 SWN PROD CO LLC 999,375.00 365 0.00 0 0.00 0
2017 SWN PROD CO LLC 577,274.00 365 0.00 0 0.00 0
2018 SWN PROD CO LLC 396,140.00 365 0.00 0 0.00 0
2019 SWN PROD CO LLC 395,350.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 SOUTHWESTERN ENERGY PROD CO Fracing Fluid Waste 1,958.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SOUTHWESTERN ENERGY PROD CO Fracturing Fluid Waste 5.58 Tons LANDFILL THR029
2014 SOUTHWESTERN ENERGY PROD CO Drill Cuttings 1,479.07 Tons LANDFILL 101247
2015 SWN PROD CO LLC Fracing Fluid Waste 4,940.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SWN PROD CO LLC Fracturing Fluid Waste 10.24 Tons LANDFILL THR029
2015 SWN PROD CO LLC Produced Fluid 3,231.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Produced Fluid 2,622.67 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Servicing Fluid 6.66 Tons LANDFILL THR029
2016 SWN PROD CO LLC Synthetic Liner Materials 49.66 Tons LANDFILL 101247
2016 SWN PROD CO LLC Other Oil & Gas Wastes 811.50 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SWN PROD CO LLC Fracturing Fluid Waste 57.33 Bbl REUSE OTHER THAN ROAD SPREADING
2017 SWN PROD CO LLC Other Oil & Gas Wastes 29.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 716.97 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Produced Fluid 638.01 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 73.33 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 118.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 147.34 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Other Oil & Gas Wastes 126.11 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 491.99 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 43.33 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Other Oil & Gas Wastes 48.39 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 2,275.33 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2227503 Primary Facility 2013-11-22 Preoperation Inspection No Violations Noted The Department was on site at the SWN Range Unit 59 Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the Salt Lick Hunting Club 1H (115-21423), Salt Lick Hunting Club 2H (115-21424), and the Salt Lick Hunting Club 3H (115-21425). All perimeter BMP’s in place to include red lined additions. Pad is 100% complete. No violations noted.
2244911 Primary Facility 2014-02-10 Routine/Complete Inspection No Violations Noted Conductor set 11/27/13
2247609 Primary Facility 2014-02-21 Drilling/Alteration No Violations Noted 20 set at 40
2262530 Primary Facility 2014-02-27 Incident- Response to Accident or Event No Violations Noted On 2/27/14, SWN contacted the Department and reported that approximately 1 bbl of oil based mud had been spilled on containment at their RU 59 Salt Lick Hunting Club Pad. Arrived on site at approximately 1500 hours. Met with the company man who explained that at about 4 AM, they had identified that a valve related to their shaker unit had frozen. They proceeded to unfreeze the valve and open it. While changing out a container, drill mud backed up in the shaker line and spilled onto the containment. They then identified that the valve was still frozen shut when they thought it was open. They then removed the released drill mud and power washed the affected area. An inspection of the containment at the shaker location by the Department revealed that the containment does appear to be sound. No further action by SWN is required at this time. The rig on-site is the SWN Rig # 10. SWN is currently drilling the 3H and is not presently scheduled to drill any other wells on this pad at this time.
2352035 Primary Facility 2015-03-10 Routine/Complete Inspection No Violations Noted I visited the Salt Lick Hunting pad with the 1H, 2H, and 3H wells on it on March 10th 2015 at about 11am. There were three wells on the pad, the 3H being a producing well. Production tree on the 1H was in place with 812 psi on the production line out with valve in the open position. A pressure of 1114 was indicated on gauge at wing valve. The cellar was tarped and covered with snow. The 1H and 2H only had 20” conductors set to 40’.
2383204 Primary Facility 2015-06-29 Routine/Complete Inspection No Violations Noted
2422025 Primary Facility 2015-10-30 Routine/Complete Inspection No Violations Noted
2423053 Primary Facility 2015-10-06 Routine/Complete Inspection No Violations Noted
2424226 Primary Facility 2015-11-12 Routine/Complete Inspection No Violations Noted
2443254 Primary Facility 2016-01-21 Routine/Complete Inspection No Violations Noted
2443437 Primary Facility 2016-01-14 Routine/Complete Inspection No Violations Noted
2450570 Primary Facility 2016-02-18 Routine/Complete Inspection No Violations Noted
2469280 Primary Facility 2016-03-30 Routine/Complete Inspection No Violations Noted
2483546 Primary Facility 2016-05-12 Routine/Complete Inspection No Violations Noted
2495795 Primary Facility 2016-06-24 Routine/Complete Inspection No Violations Noted
2501651 Primary Facility 2016-07-15 Routine/Complete Inspection No Violations Noted
2510471 Primary Facility 2016-08-12 Routine/Complete Inspection No Violations Noted
2517571 Primary Facility 2016-09-07 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:10a.m., the cellar had water below the surface casing with cement between the (13x9) annulus. The (9x5) vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the tank closed. There was 499psi on the production casing and 395psi on the production line. The permit number on the well was wrong, I contacted Afton Sterling of SWN and she informed me it would be corrected. I took a walk around the location and everything looked OK.

I left the site at 10:45a.m.

2585069 Primary Facility 2017-04-20 Routine/Complete Inspection No Violations Noted Todays inspection, 4/4/17 was conducted as a routine inspection. Site is stable. Greater than 70% vegetation has been established. All three wells appear to be in production. Well pad is fenced in and locked. No violations noted.
2610070 Primary Facility 2017-06-29 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:40p.m.

The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 541psi on the production casing and 505psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:15p.m.

2712982 Primary Facility 2018-03-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access with water .5' below grade and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2814912 Primary Facility 2018-12-13 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water and ice .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2820601 Primary Facility 2018-12-28 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. All 3 wells on pad appear to be in production. No E&S issues identified. Good vegetative stabilization present. No violations present.

For data sources see[8]