Well ID: 37-115-21459
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Gibson Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 150135
Farm/Lease Name: MARCHO W&M 3
License Status:
Spud Date:
Permit Date: 2013-09-25
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.797225
Longitude: -75.636469

For data sources see[1][2][3]

Well History

Date Event
2013-09-25 New Permit Application
2013-10-23 Performed Spud Operation
2013-12-17 Drilling Completion
2014-02-15 Perforation
2014-02-21 Performed Stimulation
2014-05-01 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-02-20 2014-03-11 7,261 5,649,210 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Rain for Rent Carrier/Base Fluid Water 7732-18-5 100 88.0036 47,413,700.0
Plexslick 957 Chemplex Friction Reducer Nonionic Surfactants Proprietary 1.5 0.00134591 725.136
Paraffinic, Naphtehenic Solvent 64742-47-8 30 0.0269182 14502.7
Poly (acrylamide-co-acrylic acid), partial sodium salt 62649-23-4 35 0.0314046 16919.8
Ammonium Chloride 12125-02-9 5 0.00448636 2417.12
Plexbreak 145 Chemplex Non-Emulsifier Methyl Alcohol 67-56-1 15 0.000142746 76.908
Diethanolamine 111-42-2 3 0.00002855 15.382
Cocamide Based Surfactant Proprietary 10 0.00009516 51.272
2-Butoxyethanol 111-76-2 15 0.000142746 76.908
Ferriplex 40 Chemplex Iron Control Trisodium Nitrilotriacetate 5064-31-3 40 0.00115981 624.874
Sodium Sulfate Anhydrous 7757-82-6 2 0.00005799 31.244
Sodium Hydroxide 1310-73-2 1 0.00002900 15.622
Hydrochloric Acid (15%) Reagent Acidizing Hydrochloric Acid 7647-01-0 15 0.0795513 42859.9
Plexhib 256 Chemplex Acid Inhibitor Propargyl Alcohol 107-19-7 10 0.00008525 45.931
C-14 to C-16 Alpha Olefins 64743-02-8 5 0.00004263 22.965
Polyethoxylated Alcohol Surfactant 68951-67-7 30 0.000255754 137.793
Thiourea/Formaldehyde Copolymer 68527-49-1 30 0.000255754 137.793
Methyl Alcohol 67-56-1 60 0.000511508 275.585
Plexcide 15G Chemplex Biocide Didecyl Dimethyl Ammonium Chloride 7173-51-5 3 0.000650374 350.402
Ethanol 64-17-5 3 0.000650374 350.402
Alkyl Dimethyl Benzyl Ammonium Chloride 68424-85-1 3 0.000650374 350.402
Glutaraldehyde 111-30-8 14 0.00303508 1635.21
Greenhib 679 Chemplex Friction Reducer Proprietary Proprietary 35 0.0084032 4527.4
Glycerine 56-81-5 20 0.00480183 2587.08
Sand (Proppant) TSS Proppant Silica Substrate 14808-60-7 100 11.326 6,102,100.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-02-21 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2014 CABOT OIL & GAS CORP 544,346.98 98 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 1,018,692.67 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 737,332.86 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 491,931.04 365 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 464,126.00 358 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 400,839.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 770.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2013 CABOT OIL & GAS CORP Drill Cuttings 888.45 Tons LANDFILL THR029
2013 CABOT OIL & GAS CORP Drilling Fluid Waste 86.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2013 CABOT OIL & GAS CORP Drill Cuttings 268.01 Tons LANDFILL 100933
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 467.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Produced Fluid 4,261.95 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 14,192.40 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 3,447.92 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 4.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 19.36 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NE004
2016 CABOT OIL & GAS CORP Produced Fluid 367.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 481.17 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 220.57 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 64.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2017 CABOT OIL & GAS CORP Produced Fluid 210.25 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 1.40 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Produced Fluid 457.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 84.88 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 163.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Produced Fluid 569.99 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2215650 Primary Facility 2013-10-23 Routine/Complete Inspection No Violations Noted The Department was on site at the Cabot Marcho, W&M Well Site to conduct a Preoperational Inspection. Well permits that have been issued for this pad are the 1H (115-21457), 2H (115-21458), 3H (115-21459) and the 4H (115-21460). All perimeter BMP’s in place and include red lined additions. The pad is approximately 80% complete. The tank pad is approximately 15% complete. No violations noted.
2225958 Primary Facility 2013-12-02 Drilling/Alteration No Violations Noted
2227407 Primary Facility 2013-12-09 Drilling/Alteration No Violations Noted drilling in the mantengo at 6924
2257236 Primary Facility 2014-03-26 Drilling/Alteration No Violations Noted flaring 3.5million /day
2319760 Primary Facility 2014-11-04 Incident- Response to Accident or Event No Violations Noted Andy Mehalko of Cabot Oil and Gas reported the spill incident to the department on 10/30/2014 at 5PM. Mr. Mehalko reported to the Department that a truck driver reported to Cabot that he forgot to disconnect the hose from a frac tank and the hose broke as he drove off. The driver did not report any loss of fluid from the hose. Resource Environmental of Montrose discovered standing fluid was at the site on 10/30/2014. The standing fluid exhibited elevated conductivity. I observed staining and white crystalline residue in several areas of the pad surface. The majority of staining and crystallization I discovered is indicative of the main pathway vacuum trucks would utilize to transport production fluid off the location. Crystallization on the pad surface was also observed in areas potentially not indicative of the main truck route to transport production fluid off the location. The most prevalent area of staining observed on the pad surface is in the southeast section of the pad; N- 41°47’49”; W-75°38”11”.
2472564 Primary Facility 2016-04-06 Routine/Complete Inspection No Violations Noted
2491973 Primary Facility 2016-06-10 Routine/Complete Inspection No Violations Noted
2513888 Primary Facility 2016-08-25 Routine/Complete Inspection No Violations Noted On 8/25/16, the Department conducted an inspection of the COG Marcho, W&M Pad 1 located in Gibson Township, Susquehanna County. Four wells associated with this pad have been drilled, stimulated, and appear to be in production. The one well that has not been drilled is the 6H (115-21461). Both the well pad and tank pad are present and appear to be stable. Storm water basins with emergency spill ways appear to be in very good condition. A well tender was on-site during the inspection and was working near the well heads. Site is half stone stabilized and half stabilized with perennial vegetation. No violations noted.
2530372 Primary Facility 2016-10-12 Routine/Complete Inspection No Violations Noted
2563574 Primary Facility 2017-02-21 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 12:35p.m., the cellar had ice at the bottom. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 619psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 13:10p.m.

2657420 Primary Facility 2017-11-06 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar had water 4' below grade with no bubbling noticed. All the (13x9) and (9x5) annuli were connected together and venting to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2682592 Primary Facility 2018-01-12 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. All 4 wells, the 1H, 2H, 3H, and 4H appear to be in production. Water within production tank containment, photo 4, is about 4" deep and had a conductivity reading of 3.4 mS. Standing water outside of and around this containment read between 200 and 400 uS. Deduction is that containment is sound. No spills detected. No violations noted.
2735939 Primary Facility 2018-05-30 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No E&S issues noted. No violations noted.
2756605 Primary Facility 2018-07-26 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 3.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2849709 Primary Facility 2019-03-04 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. As the photo's show, the site is snow covered. Overall the site appears to have good stabilization. No E&S issues identified. No violations noted.

For data sources see[9]