If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21646 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.847675,"lon":-75.757042,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 150828 | |
Farm/Lease Name: BARK EM SQUIRREL 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2014-01-16 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.847675 | |
Longitude: -75.757042 |
Date | Event |
---|---|
2014-01-16 | New Permit Application |
2014-03-03 | Performed Spud Operation |
2014-11-02 | Drilling Completion |
2015-01-01 | Perforation |
2015-01-01 | Performed Stimulation |
2015-04-09 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-01-01 | 2015-01-04 | 6,830 | 5,644,760 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ||||||||
Sand (Proppant), DAP-901, DAP-925, DWP-603, BioClear 2000, DWP-NE1, Hydrochloric Acid |
CWS | Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Friction Reducer, Biocide, Non-Emulsifier, Clean Perforations | Methanol | 67-56-1 | 60 | 0.01048 | 5986.54 | |
Calcite | 471-34-1 | 1 | 0.01695 | 9682.78 | ||||
Acetic acid | 64-19-7 | 1 | 0.00013 | 75.73 | ||||
Sorbitan monooleate | 1338-43-8 | 5 | 0.00268 | 1528.72 | ||||
Paraffinic hydrocarbon solvent | 64742-47-8 | 30 | 0.01418 | 8102.23 | ||||
Poly(oxyethylene)nonylphenol ether | 9016-45-9 | 5 | 0.00268 | 1528.72 | ||||
Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt |
68607-28-3 | 40 | 0.01693 | 9676.74 | ||||
Polyethylene glycol mixture | 25322-68-3 | 70 | 0.00607 | 3469.61 | ||||
Organic phosphonate 1 | Proprietary | 30 | 0.00398 | 2271.94 | ||||
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.00607 | 3469.61 | ||||
Crystalline silica (Quartz) | 14808-60-7 | 100 | 16.0899 | 9,194,030.0 | ||||
Olefin | Proprietary | 5 | 0.00001000 | 7.15 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0.00002000 | 12.26 | ||||
Diallyldimethylammonium chloride | 7398-69-8 | 5 | 0.00212 | 1209.59 | ||||
Fatty acids | Proprietary | 30 | 0.00008000 | 42.91 | ||||
Ammonium chloride | 12125-02-9 | 10 | 0.0016 | 913 | ||||
Illite | 12173-60-3 | 1 | 0.02193 | 12529.8 | ||||
Sodium chloride | 7647-14-5 | 1 | 0 | 1.43 | ||||
Poly(Acrylamide and Adam methyl Chloride) | 69418-26-4 | 40 | 0.01873 | 10701 | ||||
Polyoxyalkylenes | Proprietary | 30 | 0.00008000 | 42.91 | ||||
Organic phosphonate 2 | Proprietary | 10 | 0.00133 | 757.31 | ||||
Isopropanol | 67-63-0 | 40 | 0.01693 | 9676.74 | ||||
Modified thiourea polymer | 68527-49-1 | 30 | 0.00008000 | 42.91 | ||||
Amine salt | Proprietary | 5 | 0.00066 | 378.66 | ||||
Oxyalkylated polyamine | Proprietary | 5 | 0.00066 | 378.66 | ||||
Ilmenite | 98072-94-7 | 0.1 | 0.00812 | 4640.65 | ||||
Biotite | 1302-27-8 | 0.1 | 0.00893 | 5101.74 | ||||
Apatite | 64476-38-6 | 0.1 | 0.00893 | 5101.74 | ||||
Hydrochloric acid | 7647-01-0 | 37 | 0.2249 | 128510 | ||||
Propargyl Alcohol | 107-19-7 | 10 | 0.00003000 | 14.3 | ||||
Goethite | 1310-14-1 | 0.1 | 0.01054 | 6023.91 | ||||
Water | Customer & CWS | Base Fluid & Mix Water | Water | 7732-18-5 | 100 | 83.5044 | 47,715,900.0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-01-01 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SOUTHWESTERN ENERGY PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWN PROD CO LLC | 2,421,252.00 | 330 | 0.00 | 0 | 0.00 | 0 |
2016 | SWN PROD CO LLC | 1,543,836.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | SWN PROD CO LLC | 722,420.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 687,631.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 647,835.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 181.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 1,241.68 Tons | LANDFILL | 101247 |
2014 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 20.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWN PROD CO LLC | Fracturing Fluid Waste | 44.51 Tons | LANDFILL | THR029 |
2015 | SWN PROD CO LLC | Fracing Fluid Waste | 2,434.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWN PROD CO LLC | Produced Fluid | 1,831.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Other Oil & Gas Wastes | 32.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWN PROD CO LLC | Produced Fluid | 242.99 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 55.84 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Produced Fluid | 222.32 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 491.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Produced Fluid | 59.67 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 75.66 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 147.32 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Produced Fluid | 247.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 26.53 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 49.99 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2266406 | Primary Facility | 2014-03-05 | Drilling/Alteration | No Violations Noted | Conductor set |
2335364 | Primary Facility | 2015-01-09 | Incident- Response to Accident or Event | No Violations Noted | The Department was on site at the SWN Bark 'Em Squirrel Well Site to conduct a Spill Incident Investigation and met with Mike Tornes and Seth Tratthan |
2354445 | Primary Facility | 2015-03-23 | Routine/Complete Inspection | No Violations Noted | I visited the Bark Em Squirrel pad on 3/23/2015 at 12:45 pm. There were several wells on the pad, three of which were newly producing wells; the 1H, 2H, and 3H. All three of these wells had production trees in place that were tied into production lines with valve open. The 1H was producing at 1307 psi on the line out and 1738 psi on casing as indicated on wing valve gauge. The 2H had 1904 psi on casing and 1488 psi on line out. The 3H had 1668 psi on casing and 1238 psi on the line out. Cellars on these wells were under containment and appeared to have one vent pipe plumbed to surface and tied in, but isolated from, production lines. Existing containment on site, piles of torn up containment existing on site. |
2354446 | Primary Facility | 2015-03-23 | Routine/Complete Inspection | No Violations Noted | I visited the Bark Em Squirrel pad on 3/23/2015 at 12:45 pm. There were several wells on the pad, three of which were newly producing wells; the 1H, 2H, and 3H. All three of these wells had production trees in place that were tied into production lines with valve open. The 1H was producing at 1307 psi on the line out and 1738 psi on casing as indicated on wing valve gauge. The 2H had 1904 psi on casing and 1488 psi on line out. The 3H had 1668 psi on casing and 1238 psi on the line out. Cellars on these wells were under containment and appeared to have one vent pipe plumbed to surface and tied in, but isolated from, production lines. Existing containment on site, piles of torn up containment existing on site. |
2404196 | Primary Facility | 2015-09-01 | Routine/Complete Inspection | No Violations Noted | |
2472573 | Primary Facility | 2016-04-07 | Routine/Complete Inspection | No Violations Noted | |
2482627 | Primary Facility | 2016-05-10 | Routine/Complete Inspection | No Violations Noted | |
2497089 | Primary Facility | 2016-06-29 | Routine/Complete Inspection | No Violations Noted | |
2540037 | Primary Facility | 2016-11-22 | Routine/Complete Inspection | No Violations Noted | On 11/22/16, the Department conducted an inspection of the SWN RU 17 Bard Em Squirrel Pad as part of an investigation into a complaint that a nearby water supply may have been affected by natural gas drilling operations. As the attached photographs show, the pad was snow covered with no personnel present on the pad. During the inspection it appeared as if all 6 wells (1H, 2H, 3H, 5H, 6H, and 7H) present were in production, although recent correspondence from SWN suggests only 4 of the wells (1H, 2H, 3H, and 5H) were actually in production. The last well drilled and stimulated on this site is the 3H with drilling having been completed on 10/31/14 and stimulation having been completed on 1/4/15. In general, the pad appeared to be stable with no violations noted. |
2571942 | Primary Facility | 2017-03-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:40p.m.
The cellar was set up with a plastic corrugated pipe around the well for inspection access and full of ice. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure with a Crystal pressure gauge, the valve going to the production tank was closed. There was 626psi on the production casing and 578psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 15:25p.m. |
2663866 | Primary Facility | 2017-11-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2708502 | Primary Facility | 2018-03-21 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were identified. No violations noted. |
2747739 | Primary Facility | 2018-06-18 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were observed. No violations noted. |
2763787 | Primary Facility | 2018-08-15 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. The cellar was full of water and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[9]