If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-115-21708 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.899914,"lon":-75.680622,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Susquehanna | |
| Municipality: New Milford Township | |
| Operator Name: SWN PROD CO LLC | |
| Well Pad ID: 145442 | |
| Farm/Lease Name: PLATUS 1H | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2014-03-21 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.899914 | |
| Longitude: -75.680622 |
| Date | Event |
|---|---|
| 2014-03-21 | New Permit Application |
| 2014-06-04 | Performed Spud Operation |
| 2014-08-25 | Drilling Completion |
| 2014-10-02 | Perforation |
| 2014-10-10 | Performed Stimulation |
| 2015-04-03 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2014-10-10 | 2014-10-13 | 6,400 | 5,361,220 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | ||||||||
| Sand (Proppant), DAP-901, DAP-925, DWP-603, BioClear 2000, DWP-NE1, Hydrochloric Acid |
CWS | Propping Agent, Scale Inhibitor, Acid Corrosion Inhibitor, Friction Reducer, Biocide, Non-Emulsifier, Clean Perforations | Fatty acids | Proprietary | 30 | 0.0001 | 56.77 | |
| Poly(oxyethylene)nonylphenol ether | 9016-45-9 | 5 | 0.00271 | 1480.58 | ||||
| Calcite | 471-34-1 | 1 | 0.01944 | 10612.5 | ||||
| Poly(Acrylamide and Adam methyl Chloride) | 69418-26-4 | 40 | 0.01899 | 10364.1 | ||||
| Amine salt | Proprietary | 5 | 0.00066 | 357.98 | ||||
| Apatite | 64476-38-6 | 0.1 | 0.00782 | 4268.46 | ||||
| Olefin | Proprietary | 5 | 0.00002000 | 9.46 | ||||
| Organic phosphonate 2 | Proprietary | 10 | 0.00131 | 715.95 | ||||
| Crystalline silica (Quartz) | 14808-60-7 | 100 | 16.0615 | 8,766,920.0 | ||||
| Hydrochloric acid | 7647-01-0 | 37 | 0.31128 | 169910 | ||||
| Polyoxyalkylenes | Proprietary | 30 | 0.0001 | 56.77 | ||||
| Biotite | 1302-27-8 | 0.1 | 0.00782 | 4268.46 | ||||
| Formaldehyde | 50-00-0 | 0.1 | 0.00002000 | 11.64 | ||||
| Oxyalkylated polyamine | Proprietary | 5 | 0.00066 | 357.98 | ||||
| Propargyl Alcohol | 107-19-7 | 10 | 0.00003000 | 18.92 | ||||
| Acetic acid | 64-19-7 | 1 | 0.00013 | 71.6 | ||||
| Sodium chloride | 7647-14-5 | 1 | 0 | 1.89 | ||||
| Illite | 12173-60-3 | 1 | 0.01861 | 10160.4 | ||||
| Dimethylcocoamine, bis(chloroethyl) ether, diquaternary ammonium salt |
68607-28-3 | 40 | 0.01609 | 8785.02 | ||||
| Paraffinic hydrocarbon solvent | 64742-47-8 | 30 | 0.01438 | 7847.09 | ||||
| Modified thiourea polymer | 68527-49-1 | 30 | 0.0001 | 56.77 | ||||
| Diallyldimethylammonium chloride | 7398-69-8 | 5 | 0.00201 | 1098.13 | ||||
| Polyethylene glycol mixture | 25322-68-3 | 70 | 0.00591 | 3226.58 | ||||
| 2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.00591 | 3226.58 | ||||
| Isopropanol | 67-63-0 | 40 | 0.01609 | 8785.02 | ||||
| Sorbitan monooleate | 1338-43-8 | 5 | 0.00271 | 1480.58 | ||||
| Organic phosphonate 1 | Proprietary | 30 | 0.00393 | 2147.86 | ||||
| Goethite | 1310-14-1 | 0.1 | 0.00967 | 5279.17 | ||||
| Methanol | 67-56-1 | 60 | 0.01018 | 5555.79 | ||||
| Ammonium chloride | 12125-02-9 | 10 | 0.0016 | 873.75 | ||||
| Ilmenite | 98072-94-7 | 0.1 | 0.00689 | 3763.1 | ||||
| Water | Customer & CWS | Base Fluid & Mix Water | Water | 7732-18-5 | 100 | 83.4533 | 45,551,700.0 |
For data sources see[5]
| Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
|---|---|---|---|---|---|
| 2014-10-10 | 0 | 0 | 0 |
For data sources see[6]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2014 | SOUTHWESTERN ENERGY PROD CO | 232,302.00 | 38 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SWN PROD CO LLC | 1,497,013.00 | 314 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SWN PROD CO LLC | 1,169,362.00 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2017 | SWN PROD CO LLC | 758,996.00 | 364 | 0.00 | 0 | 0.00 | 0 |
| 2018 | SWN PROD CO LLC | 525,812.00 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2019 | SWN PROD CO LLC | 561,984.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2014 | SOUTHWESTERN ENERGY PROD CO | Fracing Fluid Waste | 6,206.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | SOUTHWESTERN ENERGY PROD CO | Fracturing Fluid Waste | 41.80 Tons | LANDFILL | THR029 |
| 2014 | SOUTHWESTERN ENERGY PROD CO | Drill Cuttings | 1,256.48 Tons | LANDFILL | 101247 |
| 2014 | SOUTHWESTERN ENERGY PROD CO | Produced Fluid | 3,246.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 645.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
| 2014 | SOUTHWESTERN ENERGY PROD CO | Drilling Fluid Waste | 893.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
| 2015 | SWN PROD CO LLC | Drill Cuttings | 18.45 Tons | LANDFILL | 101247 |
| 2015 | SWN PROD CO LLC | Produced Fluid | 13,665.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SWN PROD CO LLC | Other Oil & Gas Wastes | 25.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SWN PROD CO LLC | Produced Fluid | 1,434.20 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 22.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2017 | SWN PROD CO LLC | Produced Fluid | 542.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 779.80 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 301.60 Bbl | SURFACE IMPOUNDMENT | 826342 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 206.00 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 158.12 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 48.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 413.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 31.23 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 89.20 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[8]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2284255 | Primary Facility | 2014-06-13 | Drilling/Alteration | No Violations Noted | Currently at 727'. Encountered 5 bbls of water at 527'; encountered 20 bbls of water at 600'. Falcon 25 |
| 2284302 | Primary Facility | 2014-06-11 | Drilling/Alteration | No Violations Noted | Falcon 25. 20 set at 40'; 13 3/8 plan to set at approx 720'. No known shows of water on surface string. Drilling on air |
| 2300233 | Primary Facility | 2014-08-28 | Routine/Complete Inspection | No Violations Noted | |
| 2307141 | Primary Facility | 2014-09-20 | Routine/Complete Inspection | No Violations Noted | |
| 2407847 | Primary Facility | 2015-09-16 | Routine/Complete Inspection | No Violations Noted | |
| 2447617 | Primary Facility | 2016-02-05 | Routine/Complete Inspection | No Violations Noted | |
| 2481544 | Primary Facility | 2016-05-05 | Routine/Complete Inspection | No Violations Noted | |
| 2492803 | Primary Facility | 2016-06-14 | Routine/Complete Inspection | No Violations Noted | |
| 2501126 | Primary Facility | 2016-07-05 | Routine/Partial Inspection | No Violations Noted | |
| 2565629 | Primary Facility | 2017-02-24 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:40p.m.
The cellar was set up with a plastic corrugated pipe around the well for inspection access; there was water above the surface casing with no bubbling noticed. The (9x5) annulus vent pipe was open and set up with a Taylor plug to check for pressure and the valve going to the production tank was closed. There was 462psi on the production casing and 378psi on the production line. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:30p.m. |
| 2659598 | Primary Facility | 2017-11-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. There was water above the (20x13) and (13x9) annuli with no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
| 2732681 | Primary Facility | 2018-05-21 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were observed. No violations noted. |
| 2759534 | Primary Facility | 2018-08-02 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[9]