X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-21712

Well Details

Well ID: 37-115-21712
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Jessup Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 151032
Farm/Lease Name: GRASAVAGE E 2
License Status:
Spud Date:
Permit Date: 2014-03-19
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.795014
Longitude: -75.977950

For data sources see[1][2][3]

Well History

Date Event
2014-03-19 New Permit Application
2014-05-27 Performed Spud Operation
2014-07-10 Drilling Completion
2014-09-20 Perforation
2014-11-02 Performed Stimulation
2015-01-29 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2014-10-15 2014-11-08 6,165 14,499,000 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FRW-200 FTSI Friction reducer Alcohols (C12-C14), ethoxylated 68439-50-9 4 0.00345314 4711.19
Surfactant Proprietary 7 0.006043 8244.58
Water 7732-18-5 48 0.0414377 56534.3
Acrylamide 79-06-1 0.1 0.00008633 117.78
Alcohols (C10-C16), ethoxylated 68002-97-1 4 0.00345314 4711.19
Alkyloxypolyethyleneoxyethanol 84133-50-6 1 0.000863285 1177.8
Dewaxed heavy paraffinic 64742-65-0 1.5 0.00129493 1766.7
Alcohols (C12-C16), ethoxylated 68551-12-2 4 0.00345314 4711.19
Isopropanol 67-63-0 0.3 0.000258986 353.34
Petroleum distillate hydrotreated light 64742-47-8 26 0.0224454 30622.7
Ammonium Chloride 12125-02-9 12 0.0103594 14133.6
Copolymer of acrylamide and sodium acrylate 25987-30-8 33 0.0284884 38867.3
Ammonium Acrylate 10604-69-0 0.5 0.000431643 588.9
Sorbitol Tetraoleate 61723-83-9 2 0.00172657 2355.59
Polyethylene glycol monooleate 9004-96-0 3 0.00258986 3533.39
Hydrotreated heavy paraffinic 64742-54-7 5 0.00431643 5888.98
Sorbitan Monooleate 1338-43-8 3 0.00258986 3533.39
Acrylamide P/W acrylic acid, ammonium salt 26100-47-0 25 0.0215821 29444.9
FE-100L FTSI Iron control Citric acid 77-92-9 55 0.000518596 707.53
Water 7732-18-5 60 0.000565741 771.85
CI-150 FTSI Acid Corrosion Inhibitor Water 7732-18-5 5 0.00002614 35.67
Fatty Acid Proprietary 0.1 0.00000052 0.71
Aromatic aldehyde Proprietary 10 0.00005229 71.34
Fatty Acid Salt Proprietary 0.1 0.00000052 0.71
Ethylene Glycol 107-21-1 30 0.000156869 214.02
Quaternary ammonium compound Proprietary 10 0.00005229 71.34
Diethylene glycol 111-46-6 1 0.00000523 7.13
Organic amine resin salt Proprietary 30 0.000156869 214.02
Aliphatic alcohol Proprietary 0.1 0.00000052 0.71
Isopropanol 67-63-0 30 0.000156869 214.02
Dimethylformamide 68-12-2 10 0.00005229 71.34
Alkylene Oxide Block Polymer Proprietary 10 0.00005229 71.34
Water Operator Carrier Water 7732-18-5 100 88.6317 120,922,000.0
ICI-3240 FTSI Biocide Sodium Hydroxide 1310-73-2 23 0.00579096 7900.72
Water 7732-18-5 55 0.0138479 18893
Dazomet (Tetrahydro-3, 5-dimethyl-2H-1,
3, 5-thiadiazine-2-thione.
533-74-4 24 0.00604274 8244.23
CS-500 SI FTSI Scale inhibitor Ethylene glycol 107-21-1 10 0.00249824 3408.4
Water 7732-18-5 55 0.0137403 18746.2
Sodium chloride 7647-14-5 6 0.00149894 2045.04
Sodium Polyacrylate 9003-04-7 5 0.00124912 1704.2
Acrylic Polymer Proprietary 0 0 0
Hydrochloric Acid (HCl) FTSI Acid Hydrogen Chloride 7647-01-0 37 0.109595 149523
Water 7732-18-5 63 0.186608 254592
40/70 White FTSI proppant Silica, Quartz 14808-60-7 100 10.3419 14,109,700.0
100 Mesh Sand FTSI proppant Silica, Quartz 14808-60-7 100 0.592252 808021

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2014-11-02 0 0 0

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 CABOT OIL & GAS CORP 375,642.94 33 0.00 0 0.00 0
2015 CABOT OIL & GAS CORP 4,154,290.01 365 0.00 0 0.00 0
2016 CABOT OIL & GAS CORP 2,973,116.08 366 0.00 0 0.00 0
2017 CABOT OIL & GAS CORP 2,081,793.32 364 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 1,703,373.00 363 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 1,572,475.00 365 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 CABOT OIL & GAS CORP Produced Fluid 1,087.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 3,859.60 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2014 CABOT OIL & GAS CORP Drill Cuttings 1,387.44 Tons LANDFILL 101247
2014 CABOT OIL & GAS CORP Fracing Fluid Waste 21,485.24 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 9,557.81 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2015 CABOT OIL & GAS CORP Produced Fluid 5.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE001
2016 CABOT OIL & GAS CORP Produced Fluid 405.01 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2016 CABOT OIL & GAS CORP Produced Fluid 706.87 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2016 CABOT OIL & GAS CORP Produced Fluid 1,283.25 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 1,477.94 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2017 CABOT OIL & GAS CORP Produced Fluid 140.03 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2017 CABOT OIL & GAS CORP Produced Fluid 23.62 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 24.54 Bbl REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Produced Fluid 661.62 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Produced Fluid 505.79 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC018
2019 CABOT OIL & GAS CORP Produced Fluid 1,030.58 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2265928 Primary Facility 2014-04-28 Preoperation Inspection No Violations Noted
2284352 Primary Facility 2014-06-24 Drilling/Alteration No Violations Noted Condcutor set
2296108 Primary Facility 2014-07-25 Drilling/Alteration Viol(s) Noted & Immediately Corrected Patterson 263. Due to error in drilling program, surface casing was set at 780', which is 141' below the maximum setting depth allowed. Incident was self reported by Cabot. Cabot to respond with plan on how this mistake will be prevented in the future.
2357463 Primary Facility 2015-03-31 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Grasavage E. Well site. The area was partially snow covered and there were no erosional issues apparent at this time, and the site was stable. The most recent E&S Inspection was on 3/26/15. The wells associated with this site are as follows:
2365488 Primary Facility 2015-04-29 Routine/Complete Inspection No Violations Noted
2466935 Primary Facility 2016-03-22 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 10:45 a.m., the cellar had water at the bottom with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was about 660psi on the production casing. I took a walk around the location and everything looked OK.

I left the site at 11:30 a.m.

2475039 Primary Facility 2016-03-21 Routine/Complete Inspection No Violations Noted The Department was on site to conduct a routine complete inspection of the Grasavage E. Well site (ESX13-115-0105). There were no erosional issues apparent at this time, and the site was stable.

The wells associated with this site are as follows: 115-21715 115-21714 115-21713 115-21712 115-21711

There were no violations.

If there are any questions, please feel free to contact me at (570)346-5539

2526026 Primary Facility 2016-09-22 Routine/Partial Inspection No Violations Noted
2545877 Primary Facility 2016-12-16 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:10a.m., the cellar was full of ice and snow. The (13x9) vent pipe was open and venting into a small plastic tank, the (9x5) vent pipe was open and venting into a small plastic tank. There was 609psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.

I left the site at 11:45a.m.

2556287 Primary Facility 2017-01-25 Follow-up Inspection No Violations Noted The Department was on site at the Grasavage, E. Well Site located at 2993 East Rush Street Jessup Township, Susquehanna County for a Follow-Up Inspection to the Department’s 9/22/2016 inspection. I reviewed the E&S Inspection Log and found that Mike Brilla, TEC conducted the most recent inspection, which was noted as a post precipitation inspection, on 1/25/2016.

During this inspection, the Department inspected the sediment trap that was found to not have sufficient stabilization during the previous inspection. At this time, the sediment trap was filled with water and ice but erosion control blanket was visible through some areas.

The well site was about 90% snow covered during the inspection. No obvious issues were found.

2634891 Primary Facility 2017-09-11 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. All the annuli vent pipes were venting into the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2714133 Primary Facility 2018-04-03 Site Restoration No Violations Noted I inspected the Grasavage E Well Site .The cut and fill slopes were stable and had adequate vegetation in excess of 70% perennial cover. There were no erosional issues observed. The wells were properly labeled.

The wells associated with this site are as follows: 115-21712 115-21713 115-21714 115-21715.

There were no violations noted.

2728771 Primary Facility 2018-05-10 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Grasavage well site. The wells associated with this site are as follows: 115-21712, 115-21713, 115-21714, 115-21716.

These wells were properly labeled.

The cut slope was well vegetated. It was stable. The fill slope was stable and very well vegetated. There were no erosional issues noted.

The pad surface and access road were stable and solid.

There were no violations observed.

2743629 Primary Facility 2018-06-20 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water 1' below grade in the cellar and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank at 24% LEL and 4% methane. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2819787 Primary Facility 2018-12-21 Routine/Complete Inspection No Violations Noted I performed a RTNC inspection of the Grasavage well site. The weather at the time of inspection was above 60 degrees F. The sky was partly sunny and it had rained earlier in the morning. The well pad surface was damp but otherwise solid.
    The access road and pad surface were both solid and stable.  The pad surface was recently made smaller and the vegetation around the edge was doing well, as it was lush and thick.
    The cut and fill slopes were in good shape with no rills or erosional issues.  The slopes were well vegetated and stable. 
    The wells were clearly and properly labeled. 
    The infiltration basins were well vegetated and appeared to be performing their jobs.
    There were no violations noted.
2839645 Primary Facility 2019-02-07 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. There was water and ice 5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 2/5/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2296108 702886 07/25/2014 2014-07-25 78.83COALCSG - Improper coal protective casing and cementing procedures Administrative

For data sources see[9]

References