{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.671486,"lon":-75.952169,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Springville Township | |
Operator Name: CHIEF OIL & GAS LLC | |
Well Pad ID: 151256 | |
Farm/Lease Name: CLARK UNIT 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2014-05-09 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.671486 | |
Longitude: -75.952169 |
Date | Event |
---|---|
2014-05-09 | New Permit Application |
2014-07-21 | Performed Spud Operation |
2014-09-12 | Drilling Completion |
2015-07-23 | Perforation |
2015-09-05 | Performed Stimulation |
2015-12-04 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-09-05 | 2015-09-12 | 7,488 | 7,756,810 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FDP-S1176-15 | Halliburton | Friction Reducer | Petroleum Distillate | 64742-47-8 | 20 | 0.01 | 0 |
Ammonium Chloride | 12125-02-9 | 2 | 0.001 | 0 | ||||
Olecic Acid Diethanolamide | 93-83-4 | 1.5 | 0.0007 | 0 | ||||
FR-66 | Halliburton | Friction Reducer | Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.009 | 0 | |
Bactron K-139 | Champion Technologies | Biocide | Glutaraldehyde | 111-30-8 | 5 | 0.002 | 0 | |
Ethanol | 64-17-5 | 5 | 0.002 | 0 | ||||
Quaternary ammonium compounds, benzyl-C-12-16 alkyldimethyl, chlorides |
68424-85-1 | 10 | 0.004 | 0 | ||||
Hydrochloric Acid 10-30% | Halliburton | Acid | Hydrochloric Acid | 7647-01-0 | 30 | 0.028 | 0 | |
Water | Provided by Customer | Base Fluid | Fresh Water | 0000-00-0 | 100 | 100 | 0 | |
Gyptron T-390 | Champion Technologies | Scale Inhibitor | Methanol | 67-56-1 | 10 | 0.00005000 | 0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-09-05 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CHIEF OIL & GAS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CHIEF OIL & GAS LLC | 1,871,831.68 | 95 | 0.00 | 0 | 0.00 | 0 |
2016 | CHIEF OIL & GAS LLC | 5,106,477.87 | 347 | 0.00 | 0 | 0.00 | 0 |
2017 | CHIEF OIL & GAS LLC | 1,878,317.54 | 338 | 0.00 | 0 | 0.00 | 0 |
2018 | CHIEF OIL & GAS LLC | 1,025,410.39 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | CHIEF OIL & GAS LLC | 838,661.18 | 360 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 620.48 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2014 | CHIEF OIL & GAS LLC | Drill Cuttings | 1,271.56 Tons | LANDFILL | 100933 |
2014 | CHIEF OIL & GAS LLC | Drilling Fluid Waste | 996.05 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 20,369.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Drill Cuttings | 9.88 Tons | LANDFILL | 301358 |
2015 | CHIEF OIL & GAS LLC | Produced Fluid | 872.87 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CHIEF OIL & GAS LLC | Fracing Fluid Waste | 1,080.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | CHIEF OIL & GAS LLC | Fracturing Fluid Waste | 360.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | CHIEF OIL & GAS LLC | Fracturing Fluid Waste | 20,369.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHIEF OIL & GAS LLC | Produced Fluid | 2,657.44 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHIEF OIL & GAS LLC | Soil Contaminated by Oil & Gas Related Spills | 12.14 Tons | LANDFILL | 100933 |
2017 | CHIEF OIL & GAS LLC | Soil Contaminated by Oil | 12.14 Tons | LANDFILL | 100933 |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 2,589.30 Bbl | REUSE (AT WELL PAD) | |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 180.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | CHIEF OIL & GAS LLC | Produced Fluid | 80.73 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2018 | CHIEF OIL & GAS LLC | Produced Fluid | 231.02 Bbl | REUSE (AT WELL PAD) | |
2019 | CHIEF OIL & GAS LLC | Produced Fluid | 300.85 Bbl | REUSE (AT WELL PAD) |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2294308 | Primary Facility | 2014-07-18 | Routine/Partial Inspection | No Violations Noted | |
2303596 | Primary Facility | 2014-09-10 | Drilling/Alteration | No Violations Noted | |
2341250 | Primary Facility | 2015-02-04 | Routine/Complete Inspection | No Violations Noted | |
2487437 | Primary Facility | 2016-05-23 | Routine/Complete Inspection | No Violations Noted | |
2491955 | Primary Facility | 2016-06-02 | Routine/Complete Inspection | No Violations Noted | I conducted an inspection of the site accompanied by Scott Kuchta, DEP O&G WQS. Flowback operations were in progress as we arrived at 12:15 PM. Oil States Energy Services is the Chief subcontractor conducting the flowback. Shortly after our arrival, we met with Mason Hope, well tester, of Oil States. Mr. Hope stated the following information. "Flowback of the Clark unit 1H well started on 5/30/16. The well is making water and gas, with the gas being sent directly to sales. Thus far 3,000 barrels of fluid have been recovered at a rate of 40 barrels/hour. The fluid is sent to frac tanks on-site in a tank battery. Water from the sand trap is sent to the gas buster tank. A line heater and separate is used in the flowback process. The frac tanks were -site before the flowback started. The 3H well is in production. The 2H well has not been stimulated and is shut in."
I recorded 3.7 milliSiemens/cm³ conductivity in water in the frac tank battery containment in the Northeast section of the pad. There were |
2500463 | Primary Facility | 2016-06-28 | Routine/Complete Inspection | No Violations Noted | |
2507694 | Primary Facility | 2016-08-02 | Follow-up Inspection | No Violations Noted | |
2508895 | Primary Facility | 2016-08-03 | Incident- Response to Accident or Event | No Violations Noted | |
2564071 | Primary Facility | 2017-02-21 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | The operator reported a release of brine water to the ground from the Clark 3H Well on 21FEB2016 at 10:36 AM. The reported release was estimated to be 3 gallons maximum. The brine was reported to have been released as a mist from the Gas Buster Tank while conducting coiled tubing operations.
The operator further detailed remediation of the release consisted of establishing an area of 50' x 50' where the greatest potential for contamination to have occurred. The area was screened by observation and TDS screening. The estimated amount of the release been reported as a conservative estimated of no more than three gallons. The potentially contaminated material was excavated and disposed of by Waste Management. The operator would provide a final report of the incident. I conducted the site visit and had met with Aaron Stredney, Environmental Inspector for Chief Oil & Gas. The reporting and response to the spill by the operator appears to have diminished the potential of this incident to cause environmen |
2582968 | Primary Facility | 2017-04-14 | Follow-up Inspection | No Violations Noted |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2564071 | 779036 | 2017-02-21 | 2017-02-21 | 91.34(A) | Environmental Health & Safety | The operator failed to prevent a release of a substance which could potentially pollute the waters of the Commonwealth. In this case, the substance was brine water used in the coiled tubing operations.
The volume and immediate response by the operator appeared to have reduced the potential of envi |