If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-21815 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.829644,"lon":-75.823811,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Bridgewater Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 151400 | |
Farm/Lease Name: FONTANA C 4 | |
License Status: | |
Spud Date: | |
Permit Date: 2014-06-09 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.829644 | |
Longitude: -75.823811 |
Date | Event |
---|---|
2014-06-09 | New Permit Application |
2014-09-18 | Performed Spud Operation |
2014-12-14 | Drilling Completion |
2015-01-18 | Perforation |
2015-02-23 | Performed Stimulation |
2015-06-09 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-02-22 | 2015-03-03 | 6,515 | 6,436,420 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Greenhib 679 | Chemplex | Friction Reducer | Glycerine | 56-81-5 | 20 | 0.00476747 | 2908.6 |
Proprietary | Proprietary | 35 | 0.00834307 | 5090.05 | ||||
Chemplex 4-N-1 | Chemplex | Combination/Iron Control | Propargyl Alcohol | 107-19-7 | 1 | 0.00001875 | 11.439 | |
n-olefins | Proprietary | 1 | 0.00001875 | 11.439 | ||||
Methyl Alcohol | 67-56-1 | 10 | 0.000187504 | 114.395 | ||||
Acetic Acid | 64-19-7 | 85 | 0.00159378 | 972.357 | ||||
thiourea-formaldehyde copolymer | 68527-49-1 | 2 | 0.00003750 | 22.879 | ||||
2-Ethylhexanol | 104-76-7 | 10 | 0.000187504 | 114.395 | ||||
Cocamide Diethanolamine Salt | 68603-42-9 | 2 | 0.00003750 | 22.879 | ||||
Diethanolamine | 111-42-2 | 2 | 0.00003750 | 22.879 | ||||
Alcohol Ethoxylate Surfactants | Proprietary | 2 | 0.00003750 | 22.879 | ||||
Plexcide 15G | Chemplex | Biocide | Alkyl Dimethyl Benzyl Ammonium Chloride | 68424-85-1 | 3 | 0.000646297 | 394.301 | |
Glutaraldehyde | 111-30-8 | 14 | 0.00301605 | 1840.07 | ||||
Didecyl Dimethyl Ammonium Chloride | 7173-51-5 | 3 | 0.000646297 | 394.301 | ||||
Ethanol | 64-17-5 | 3 | 0.000646297 | 394.301 | ||||
Plexslick 957 | Chemplex | Friction Reducer | Paraffinic, Naphtehenic Solvent | 64742-47-8 | 30 | 0.0232576 | 14189.3 | |
Poly (acrylamide-co-acrylic acid), partial sodium salt | 62649-23-4 | 35 | 0.0271339 | 16554.2 | ||||
Nonionic Surfactants | Proprietary | 1.5 | 0.00116288 | 709.466 | ||||
Ammonium Chloride | 12125-02-9 | 5 | 0.00387627 | 2364.89 | ||||
Sand (Proppant) | TSS | Proppant | Silica Substrate | 14808-60-7 | 100 | 11.2194 | 6,844,900.0 | |
Water | Rockwater | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.3503 | 53,901,900.0 | |
Hydrochloric Acid (15%) | Reagent | Acidizing | Hydrochloric Acid | 7647-01-0 | 15 | 0.0458259 | 27958.1 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-02-23 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CABOT OIL & GAS CORP | 2,395,494.11 | 279 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 1,714,196.13 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 898,983.53 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 605,763.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 343,759.00 | 362 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 269.52 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014 | CABOT OIL & GAS CORP | Drill Cuttings | 1,072.28 Tons | LANDFILL | 101247 |
2014 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 90.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 115.02 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 10,358.64 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 4,780.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 25.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 115.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 251.66 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 77.54 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 156.75 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 96.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 54.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 119.64 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2294051 | Primary Facility | 2014-08-01 | Incident- Response to Accident or Event | No Violations Noted | |
2300950 | Primary Facility | 2014-09-04 | Administrative/File Review | No Violations Noted | Violations immediately corrected are associated with the site. The ESCGP number is ESX29-115-14-0004. E-facts identification number is 2300929. |
2300961 | Primary Facility | 2014-09-03 | Administrative/File Review | No Violations Noted | Violations immediately corrected are associated with the site. The ESCGP number is ESX29-115-14-0004. E-facts identification number is 2300958. |
2303059 | Primary Facility | 2014-08-25 | Routine/Partial Inspection | No Violations Noted | |
2304019 | Primary Facility | 2014-09-09 | Routine/Partial Inspection | No Violations Noted | |
2347537 | Primary Facility | 2015-02-24 | Routine/Complete Inspection | No Violations Noted | The Department was on site to perform a routine complete inspection at the Fontana Well Pad |
2367118 | Primary Facility | 2015-05-05 | Routine/Complete Inspection | No Violations Noted | |
2381023 | Primary Facility | 2015-06-22 | Routine/Partial Inspection | No Violations Noted | |
2437388 | Primary Facility | 2016-01-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:40 p.m., the cellar was full of water with no bubbling noticed, the (13x9) vent pipe was open and venting to a tank, the (9x5) vent pipe was open and venting to a tank, there was 606psi on the production casing. I took a walk around the location and everything looked OK.
I left the site at 14:10 p.m. |
2498887 | Primary Facility | 2016-06-27 | Complaint Inspection | No Violations Noted | 1900- Spoke to Complainant about the noise and grey/white smoke coming from the C. Fontana well pad. Complainant indicated that a loud hissing noise with grey/white billowing smoke was coming from the C. Fontana well pad. Complainant stated that she called the Cabot emergency number. Cabot informed Complainant that personnel are in the process of relieving pressure from the production equipment. Complainant voiced concerns about the duration (approximately 20 minutes) and the presence of the smoke.
Arrived at the C. Fontana well pad, the gate at the access road was locked. There weren't any Cabot personnel on-site. On the well pad, no noise or smoke was detected. Inspected the C. Fontana 2H, 4H and 6H gas wells. The wells were in production. No leaks were detected at the well heads and no bubbling was observed in the water filled well cellars. The gas production units (GPUs) for the C. Fontana wells were inspected. No leaks were detected. No evidence of spills were observed around the well heads or GPUs. Ins |
2498892 | Primary Facility | 2016-06-28 | Complaint Inspection | No Violations Noted | On 6/28/2016, David Schoonover (DEP-Oil and Gas Inspector) contacted Michael Hall (Cabot- Production Foreman). Mr. Hall indicated that, at the time of the complaint, Scott Allen (Cabot Well Tender) was at the C. Fontana pad blowing down the C. Fontana 4H in an effort to remove fluid from the well. No issues were reported during this process. |
2508884 | Primary Facility | 2016-06-13 | Routine/Complete Inspection | No Violations Noted | Inspection of the Fontana C P1 well pad in conjunction with the Fontana Well Connect Pipeline notice of termination inspection. There were no issues observed on the well pad at the time of the inspection. |
2538861 | Primary Facility | 2016-11-22 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 9:55a.m., the cellar had water at the bottom with no bubbling noticed. The (13x9) vent pipe was open and venting into a small poly tank, the (9x5) vent pipe was open and venting into a small poly tank. There was 506psi on the production casing. I took a walk around the location and there were no obvious concerns noticed.
I left the site at 10:30a.m. |
2559583 | Primary Facility | 2017-02-08 | Routine/Complete Inspection | No Violations Noted | The Department was on site at the Fontana well site located at 2639 Post Pond Road Bridgewater Township to conduct a Routine Complete Inspection. I reviewed the E&S Inspection Log which stated that Sam Wiernusz conducted the most recent inspection on 2/2/17 and it was a Post Precipitation Inspection. The site appeared to meet temporary stabilization requirements. Several areas on the site appeared to have been recently seeded and mulched/covered in erosion control blanket. |
2601909 | Primary Facility | 2017-05-30 | Incident- Response to Accident or Event | No Violations Noted | The Department received a report from Cabot Oil and Gas concerning a release that occurred on 5/25/17 at 1700 hours. Mr. Watson contacted the DEP after hours hotline at 1753 and received a return call from Bob Bisignani (DEP). It was reported as less than 1bbl, but the exact volume was not determined. A well was being flowed black into a flow back tank in an attempt to increase gas production on the 2H well. A well tubing hanger was temporarily removed, to increase the diameter of the well, and the well was flowed to a flowback tank. When the well was turned back in line fluid in the gas supply line (not typical) was forced to the GPU.
I met with Mr. Watson on site to conduct the inspection. The inspection was conducted during a heavy rainstorm. . |
2626925 | Primary Facility | 2017-08-16 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:00p.m.
The cellar had water at the bottom with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. All the annulus vent pipes were connected to one pipe going into the same tank. There was 488psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:40p.m. |
2676729 | Primary Facility | 2017-12-27 | Site Restoration | No Violations Noted | I performed a Notice of Termination (NOT) inspection on the Fontana well site on December 27, 2017. The site was solid and stable and the slopes were all well covered with last years vegetation, at or in excess of the 70% perennial growth standard required.
The well pad has been reduced in size from approximately 765'x330' to 343'x265'. The vegetated filter strip PCSM is in place and well vegetated with last years growth. All wells were properly labeled and had a legible tag The wells associated with this site are as follows: 115-21814 115-21815 115-21816
I recommend APPROVAL of this NOT. |
2679077 | Primary Facility | 2017-12-27 | Routine/Complete Inspection | No Violations Noted | I performed a Notice of Termination (NOT) inspection on the Fontana well site on December 27, 2017. The site was solid and stable and the slopes were all well covered with last years vegetation, at or in excess of the 70% perennial growth standard required.
The well pad has been reduced in size from approximately 765'x330' to 343'x265'. The vegetated filter strip PCSM is in place and well vegetated with last years growth. All wells were properly labeled and had a legible tag The wells associated with this site are as follows: 115-21814 115-21815 115-21816
|
2739464 | Primary Facility | 2018-06-04 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was water 7.5' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2833488 | Primary Facility | 2019-01-30 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was full of ice and was unable to check for gas. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 1/2/19. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[9]