Well ID: 37-115-21914 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.789053,"lon":-75.863083,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Bridgewater Township | |
Operator Name: CABOT OIL & GAS CORP | |
Well Pad ID: 152062 | |
Farm/Lease Name: GROOVER S 14 | |
License Status: | |
Spud Date: | |
Permit Date: 2014-11-04 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.789053 | |
Longitude: -75.863083 |
Date | Event |
---|---|
2014-11-04 | New Permit Application |
2015-01-14 | Performed Spud Operation |
2015-02-27 | Drilling Completion |
2015-07-31 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-05-02 | 2015-05-07 | 6,862 | 8,671,350 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Plexgel 10L | Chemplex | Gel Breaker | No hazardous ingrediants | Proprietary | 100 | 0.00002245 | 18.359 |
Hydrochloric Acid (15%) | Reagent | Acidizing | Hydrogen Chloride | 7647-01-0 | 15 | 0.0413417 | 33815.3 | |
FE-4 | PVS Chemical | Iron Controller / Reducers | Citric Acid | 77-92-9 | 50 | 0.000325957 | 266.615 | |
Water | 7732-18-5 | 50 | 0.000325957 | 266.615 | ||||
MSI-7 | PVS Energy Group | Scale Inhibitor | Hydrocloric Acid | 7647-01-0 | 9 | 0.0020301 | 1660.52 | |
Water | 7732-18-5 | 91.3 | 0.020583 | 16835.8 | ||||
Sand (Proppant) | Silica | Proppant | Crystalline Silica in the form of Quartz | 14808-60-7 | 99.9 | 11.1047 | 9,083,030.0 | |
Plexcide 15G | Chemplex | Biocide | Glutaraldehyde | 111-30-8 | 14 | 0.00314198 | 2569.97 | |
Ethanol | 64-17-5 | 3 | 0.000673281 | 550.707 | ||||
Didecyl dimethyl ammonium chloride | 7173-51-5 | 3 | 0.000673281 | 550.707 | ||||
Alky dimethyl benzyl ammonium chloride | 68424-85-1 | 3 | 0.000673281 | 550.707 | ||||
Plexgel 907L-EB | Chemplex | Gelling Agents | C13 n-alkanes, mixed | 629-50-5 | 20 | 0.00005093 | 41.658 | |
Propylene Pentamer | 15220-87-8 | 60 | 0.000152791 | 124.975 | ||||
C12 n-alkanes, mixed | 112-40-3 | 20 | 0.00005093 | 41.658 | ||||
Distillate, petroleum, hydrotreated light | 64742-47-8 | 60 | 0.000152791 | 124.975 | ||||
C14 n-alkanes, mixed | 629-59-4 | 20 | 0.00005093 | 41.658 | ||||
C11 n-alkanes, mixed | 1120-21-4 | 20 | 0.00005093 | 41.658 | ||||
Water | Operator | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 88.4685 | 72,362,400.0 | |
Plexslick 953 | Chemplex | Friction Reducer | Hydrotreated Light Distilate | 64742-47-8 | 20 | 0.0185494 | 15172.4 | |
B2000 | Weatherford | Biocide | Polyethylene Glycol Mixture | 25322-68-3 | 60 | 0.000440253 | 360.103 | |
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.000146751 | 120.034 | ||||
AI 30 | CorsiTech | Corrosion Inhibitor | Fatty Alcohol Ethoxylate | Proprietary | 30 | 0.000219751 | 179.744 | |
Isopropyl Alcohol | 67-63-0 | 60 | 0.000439502 | 359.489 | ||||
Ethoxylated Alcohol | Proprietary | 10 | 0.00007325 | 59.915 | ||||
Alkyl Amine Surfactant | Proprietary | 5 | 0.00003663 | 29.957 | ||||
Aromatic Aldehyne | Proprietary | 10 | 0.00007325 | 59.915 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | CABOT OIL & GAS CORP | 3,256,527.47 | 191 | 0.00 | 0 | 0.00 | 0 |
2016 | CABOT OIL & GAS CORP | 3,281,502.63 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CABOT OIL & GAS CORP | 1,940,010.37 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CABOT OIL & GAS CORP | 1,440,605.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CABOT OIL & GAS CORP | 1,126,279.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 7,305.95 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Fracing Fluid Waste | 252.71 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE001 |
2015 | CABOT OIL & GAS CORP | Drilling Fluid Waste | 25.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | CABOT OIL & GAS CORP | Produced Fluid | 2,502.08 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2015 | CABOT OIL & GAS CORP | Drill Cuttings | 1,830.96 Tons | LANDFILL | 101247 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 316.96 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NE002 |
2016 | CABOT OIL & GAS CORP | Produced Fluid | 447.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 415.13 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2017 | CABOT OIL & GAS CORP | Produced Fluid | 297.77 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 176.83 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2018 | CABOT OIL & GAS CORP | Produced Fluid | 337.36 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
2019 | CABOT OIL & GAS CORP | Produced Fluid | 442.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NE002 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2343449 | Primary Facility | 2015-01-13 | Preoperation Inspection | No Violations Noted | The Department was on site at the Groover, S. Pad 1 to conduct a Preoperational Inspection. At the time of the inspection, the Site ID Sign had been installed and the E&S Plan was on site. The E&S Inspection Log indicated that a weekly inspection was conducted by Dillon Otten on 1/12/15. The E&S plan had several redlines including additional sections of filter sock added, two elongated soil stockpiles, a fuel containment area, and a temporary culvert. |
2357473 | Primary Facility | 2015-04-02 | Routine/Complete Inspection | No Violations Noted | |
2398596 | Primary Facility | 2015-08-14 | Routine/Complete Inspection | No Violations Noted | |
2440787 | Primary Facility | 2015-11-13 | Routine/Complete Inspection | No Violations Noted | Inspection in conjunction with the notice of termination inspection of the Vandermark Pipeline. No issued observed at the time of the inspection. |
2509636 | Primary Facility | 2016-08-10 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 14:30p.m., the cellar was full of water with no bubbling noticed, the (13x9) vent pipe was open and venting into a tank, the (9x5) vent pipe was open and venting into a tank, there was 552psi on the production casing. I took a walk around the location and everything looked OK.
I left the site at 15:00p.m. |
2597052 | Primary Facility | 2017-05-16 | Routine/Complete Inspection | No Violations Noted | The Department was on site to conduct a Routine Complete Inspection. At the time of my arrival, I met with Ray Peplinski (Chief Inspector-Williams). The E&S Inspection Log stated that the most recent inspection was a post precipitation inspection conducted on. 5/15/17 by Anna Bonczek (TEC). |
2603253 | Primary Facility | 2017-06-08 | Routine/Complete Inspection | No Violations Noted | At time of inspection, arrived on site at 13:55p.m.
The cellar was full of water with no bubbling noticed. The (13x9) annulus vent pipe was open and venting into a small plastic tank, the (9x5) annulus vent pipe was open and venting into a small plastic tank. There was 581psi on the production casing. I took a walk around the location and there were no obvious concerns noticed. I left the site at 14:30p.m. |
2709590 | Primary Facility | 2018-03-20 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There was ice at the bottom of the cellar and there was no gas detected. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same tank. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2806035 | Primary Facility | 2018-11-21 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. There cellar was full of water and there was no bubbling noticed. The (13x9) and (9x5) annuli vent pipes were connected together and going to the same poly vent tank. There was gas detected at the poly vent tank with a MSA Altair 5X multi gas detector that was calibrated on 11/2/18. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[8]