Well ID: 37-115-22215 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.853719,"lon":-75.5962,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: Jackson Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 146202 | |
Farm/Lease Name: BOMAN 3H | |
License Status: UNDEFINED | |
Spud Date: | |
Permit Date: 2016-09-23 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.853719 | |
Longitude: -75.5962 |
Date | Event |
---|---|
2016-09-23 | New Permit Application |
2017-05-14 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-11-23 | 2017-11-27 | 6,670 | 8,278,430 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | SI-1200 | U.S. Well Services, LLC | Scale Inhibitor | Ethylene Glycol | 107-21-1 | 40 | 0.00692 | 5681.64 |
Ammonia | 7664-41-7 | 0.5 | 0.00009000 | 75.987 | ||||
CPS 500 | U.S. Well Services, LLC | Fluid Loss Additive | Ceramic Microspheres | 66402-68-4 | 65 | 2.6076 | 2,142,380.0 | |
Glutaraldehyde | 111-30-8 | 1 | 0.02798 | 22985 | ||||
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 12.753 | 10,477,800.0 | |
AI-303 | U.S. Well Services, LLC | Acid Corrosion Inhibitors | Cinnamaldehyde | 104-55-2 | 20 | 0.00006000 | 48.2919 | |
Ethylene glycol | 107-21-1 | 40 | 0.00016 | 133.573 | ||||
Acetophenone,thiourea,formaldehyde polymer | 68527-49-1 | 5 | 0.00001000 | 11.676 | ||||
Formic acid | 64-18-6 | 20 | 0.00006000 | 46.704 | ||||
Butyl cellosolve | 111-76-2 | 20 | 0.00005000 | 42.0803 | ||||
Polyether | 60828-78-6 | 10 | 0.00003000 | 23.352 | ||||
K-BAC 1005 | U.S. Well Services, LLC | Anti-Bacterial Agent | Water | 7732-18-5 | 44.3 | 0.00568 | 4666.31 | |
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 5.76 | 0.00181 | 1487.08 | ||||
Polyethylene Glycol | 25322-68-3 | 50 | 0.00718 | 5898.72 | ||||
HCL Acid (12.6%-17.5%) | U.S. Well Services, LLC | Bulk Acid | Water | 7732-18-5 | 87.4 | 0.382 | 313849 | |
Hydrogen Chloride | 7647-01-0 | 17.5 | 0.08881 | 72969.2 | ||||
WFRA-2000 | U.S. Well Services, LLC | Friction Reducer | 2-Propenoic acid, polymer with 2 propenamide | 9003-06-9 | 30 | 0.022 | 18071.9 | |
Hydrated light distillate (petroleum) | 64742-47-8 | 30 | 0.01804 | 14819 | ||||
Water | 7732-18-5 | 60 | 0.04399 | 36143.9 | ||||
Water | Southwestern Energy | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 84.0345 | 69,042,100.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 2,589,674.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 1,020,866.00 | 358 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 16.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Synthetic Liner Materials | 8.05 Tons | LANDFILL | 101247 |
2017 | SWN PROD CO LLC | Produced Fluid | 370.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Unused Fracturing Fluid Waste | 2.57 Tons | LANDFILL | 301358 |
2017 | SWN PROD CO LLC | Unused Fracturing Fluid Waste | 32.00 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 490.17 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Drill Cuttings | 1,147.19 Tons | LANDFILL | 101247 |
2018 | SWN PROD CO LLC | Produced Fluid | 5,204.66 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 77.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWN PROD CO LLC | Produced Fluid | 11.14 Tons | LANDFILL | 301358 |
2018 | SWN PROD CO LLC | Produced Fluid | 151.33 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 162.56 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Filter Socks | 0.04 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2018 | SWN PROD CO LLC | Produced Fluid | 539.50 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 57.54 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 401.33 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 107.49 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Produced Fluid | 18.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2593815 | Primary Facility | 2017-05-15 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 8:45a.m. for a new spud inspection.
Minichi Contracting Group was on site and putting in the cellars. Minichi Contracting Group drilled the holes and ran the conductor pipe with a dual rotary rig on the 2H, 3H, 4H, 5H, and 6H wells. I spoke with driller Keith Bowman of Minichi, all the conductors were drilled and set at 88'. The drill cuttings were put into a sealed role off container and hauled to the Keystone Landfill. I took a walk around the location and there were no obvious concerns noticed. I left the site at 9:05a.m. |
2605595 | Primary Facility | 2017-06-19 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 9:10a.m.
I met with company man Tony Anthony. Falcon Rig 25 was on site and pulling drill pipe. They will pull up 2000' and start loading the hole with OBM. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 5650'. The projected TD for the top hole section of the well is 5650'. I left the site at 10:20a.m. |
2639066 | Primary Facility | 2017-08-15 | Routine/Complete Inspection | No Violations Noted | |
2659189 | Primary Facility | 2017-11-02 | Routine/Complete Inspection | No Violations Noted | I arrived at the site at 11:22. I met with Mike Deming, Senior Regulatory Analyst and Frank Kelly Containment Coordinator both of SWNPC and Chris Anderson of Well Water Solutions. Mr. Anderson and Mr. Deming informed me the following. "Construction of the tank started yesterday. The inner tank is completed. The are (2) liners on the inner tank and (1) on the outer. Geotextile felt, (8) ounces, is on the seam of the tank walls. Geotextile felt is also on the pad surface at the bottom of the tanks, with (3) liners set in place on top of it. We still have to finish pulling the liner over the outer tank yet. The water will go from a valve cellar on the pad through a (12) inch high density polyethylene line made of plastic material and then will be pumped into the tank. The water transferred into the tank is pumped from nearby well development impoundments and the nearby Zeffer centralized wastewater impoundment through underground pipelines to the valve cellar in the corner of the pad at the base of the cut slop |
2665864 | Primary Facility | 2017-11-28 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
I met with company man Chris Henry. USWS (U. S. Well Services) was on site to frac the 2H, 3H, 4H, 5H, and 6H wells. They finished running the plug and perf after stage 2 and were preparing to frac stage 3 out of 24 stages on the 2H. The 3H was completed with 26 stages. The 4H was completed with 22 stages. The 5H was completed with 21 stages. The 6H was completed with 28 stages. The water was being pumped to the location from the Young fresh water impoundment. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2676328 | Primary Facility | 2017-12-27 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. Crews on-site installing new containment. Good well pad stabilization. No violations were noted. |
2688023 | Primary Facility | 2018-01-23 | Incident- Response to Accident or Event | No Violations Noted | Today's inspection was conducted as an incident inspection. At approximately noon today, Mike Deming, SWN Senior Regulatory Analyst contacted the Department to inform the Department that SWN had identified stormwater discharges off of secondary containment on 3 of their pads, of which this pad is one. Present during the inspection was Dillon Otten, SWN Regulatory Analyst. The Department metered for conductivity on the outside of the containment and had readings ranging from 40 uS to 255 uS. Standing water inside containment was read at 60 uS at the lowest point of containment where a discharge had occurred. 6 empty water tanks located on containment. No E&S violations were noted. No violations were observed. |
2722771 | Primary Facility | 2018-04-23 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was recently completed and put in production. The well tag was on the well and correct. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2824287 | Primary Facility | 2019-01-09 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. The cellar was full of water and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[8]