37-115-22256

Well Details

Well ID: 37-115-22256
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Harford Township
Operator Name: CABOT OIL & GAS CORP
Well Pad ID: 153964
Farm/Lease Name: JEFFERS FARMS 13
License Status:
Spud Date: 2017-02-23
Permit Date: 2016-11-22
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.772147
Longitude: -75.742019

For data sources see[1][2][3]

Well History

Date Event
Deviated
2016-11-22 New Permit Application
2017-02-20 Performed Spud Operation
2017-12-25 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-05-02 2018-06-07 7,088 24,074,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid (15%) Keane Acidizing Hydrochloric Acid 7647-01-0 15 0.00392105 8981.1
Water 7732-18-5 7.5 0.00196052 4490.55
Iron Control, KFEAC-20/30 Keane Iron Control Acetic acid 64-19-7 5 0.000108634 248.825
Citric acid 77-92-9 30 0.000651806 1492.95
Biocide, MBC-516 Keane Biocide ethanal 64-17-5 2.8 0.000261787 599.618
didecyldimethylammonium chloride 7173-51-5 8 0.000745157 1706.77
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.00049646 1137.13
Glutaral 111-30-8 26.7 0.00249632 5717.79
Water 7732-18-5 56.7 0.00530305 12146.6
Water Cabot Carrier/Base Fluid Water 7732-18-5 100 87.7128 200,905,000.0
Friction Reducer, KFR-23 Keane Friction Reducer Copolymer of 2-propenamide 69418-26-4 20 0.0201722 46204
alcohols, C 12-16, ethoxylated 68551-12-2 2 0.00201722 4620.4
oleic acid diethanolamide 93-83-4 2 0.00201722 4620.4
Petroleum distillate 64742-47-8 20 0.0201722 46204
Water 7732-18-5 50 0.0504304 115510
Acid Inhibitor, KAI-12 Keane Acid Inhibitor formic acid 64-18-6 10 0.00007722 176.876
Ethylene glycol 107-21-1 40 0.000308888 707.502
dipropylene gylcol, monomethyl ether 34590-94-8 20 0.000154444 353.751
isoproyl alcohol 67-63-0 5 0.00003861 88.438
Ethoxylated alcohol 68131-39-5 10 0.00007722 176.876
Cinnamaldehyde 104-55-2 10 0.00007722 176.876
Tar bases, quinoline derivs., benzyl chloride-quaternized 72480-70-7 10 0.00007722 176.876
Other Chemical(s) Listed Above See Trade Name(s) List organic phosphonic salts 15827-60-8 15 0.00266599 6106.41
alcohols, C 12-16, ethoxylated 68551-12-2 2 0.00201722 4620.4
oleic acid diethanolamide 93-83-4 2 0.00201722 4620.4
Tar bases, quinoline derivs., benzyl chloride-quaternized 72480-70-7 10 0.00007722 176.876
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.00049646 1137.13
Water 7732-18-5 7.5 0.00196052 4490.55
Cinnamaldehyde 104-55-2 10 0.00007722 176.876
didecyldimethylammonium chloride 7173-51-5 8 0.000745157 1706.77
Citric acid 77-92-9 30 0.000651806 1492.95
formic acid 64-18-6 10 0.00007722 176.876
Copolymer of 2-propenamide 69418-26-4 20 0.0201722 46204
Petroleum distillate 64742-47-8 20 0.0201722 46204
ethanal 64-17-5 2.8 0.000261787 599.618
Glutaral 111-30-8 26.7 0.00249632 5717.79
isoproyl alcohol 67-63-0 5 0.00003861 88.438
dipropylene gylcol, monomethyl ether 34590-94-8 20 0.000154444 353.751
Ethoxylated alcohol 68131-39-5 10 0.00007722 176.876
Scale Inhibitor, KSI-19NW Keane Scale Inhibitor organic phosphonic salts 15827-60-8 15 0.00266599 6106.41
Water 7732-18-5 95 0.0168846 38673.9
Sand (Proppant) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 12.1301 27,783,900.0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 CABOT OIL & GAS CORP 0.00 0 0.00 0 0.00 0
2018 CABOT OIL & GAS CORP 4,185,210.00 167 0.00 0 0.00 0
2019 CABOT OIL & GAS CORP 5,404,941.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 CABOT OIL & GAS CORP Soil Contaminated by Oil 0.02 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2017 CABOT OIL & GAS CORP Drill Cuttings 1,496.63 Tons LANDFILL 101247
2017 CABOT OIL & GAS CORP Soil Contaminated by Oil & Gas Related Spills 0.02 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 CABOT OIL & GAS CORP Produced Fluid 22,760.05 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2018 CABOT OIL & GAS CORP Synthetic Liner Materials 22.93 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Produced Fluid 21,002.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2018 CABOT OIL & GAS CORP Waste Water Treatment Sludge 90.96 Tons REUSE (AT WELL PAD)
2018 CABOT OIL & GAS CORP Unused Fracturing Fluid Waste 5.93 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Drill Cuttings 17.34 Tons LANDFILL 101247
2018 CABOT OIL & GAS CORP Other Oil & Gas Wastes 0.07 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2019 CABOT OIL & GAS CORP Produced Fluid 989.64 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE002
2019 CABOT OIL & GAS CORP Waste Water Treatment Sludge 1.18 Tons REUSE (AT WELL PAD)
2019 CABOT OIL & GAS CORP Produced Fluid 3,305.10 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NE004
2019 CABOT OIL & GAS CORP Synthetic Liner Materials 2.18 Tons LANDFILL 101247

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2561971 Primary Facility 2017-02-15 Preoperation Inspection No Violations Noted
2565627 Primary Facility 2017-02-24 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 12:30p.m. for a new spud inspection.

I met with company man Glenn Broussard. United Drilling was on site to drill and set the conductor pipe Upon arrival, O Tex was on site to cement the conductor pipe on the 7H, 10H, 11H, and 13H. The conductor pipe was set at 94' on all four wells. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:15p.m.

2623653 Primary Facility 2017-08-09 Routine/Complete Inspection No Violations Noted Today's inspection, 7/19/17 is being conducted as a routine inspection. No pictures were added to this inspect due to an electronic glitch. Drilling rig still on-site. Signage is up and displayed. Good vegetative growth occurring on all sections of the site. Vegetation a mixture of annuals and perennials with clovers being the most dominant perennial. No violations were observed during this inspection. Drilling set up looked very streamlined and organized.
2625621 Primary Facility 2017-08-10 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 12:50p.m.

I met with company man Tony Ketterling. Nabors X36 Rig was on site, the rig completed drilling the hole for the intermediate casing on the 15H to a depth of 2080' and was pulling the drill pipe out of the hole. There was no significant amount of gas detected while drilling the intermediate section and no ACP will be used. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:55p.m.

2627618 Primary Facility 2017-08-17 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 11:00a.m. as part of a migration investigation, accompanied by DEP Geologist Andrea Mullen and WQS Gene Rickard.

We met with Steve Watson and Marshall McCarty of Cabot Oil and Gas and Prad Jadeja of Selman & Associates. Andrea used an Altair 5X gas meter calibrated on 8/16/17 and Prad used a Sensit HXG-3 gas meter to check for gas. We checked for gas at the vent lines at the edge of the pad, if gas was detected at the (13x9) annulus vent line, we went to the cellar so we could determine if the gas was coming from the (20x13) annulus or the (13x9) annulus. The 9H, 7H, 8H, 10H, 14H, and 12H wells were drilled to TD. The 11H, 15H, 13H, 17H, 16H, and 18H wells were partially drilled with the surface and intermediate casings cemented into place I left the site at 13:30p.m.

2639048 Primary Facility 2017-08-17 Complaint Inspection No Violations Noted Todays inspection, 8/17/17 was conducted as part of a Department investigation into a nearby water supply complaint. This inspection centered around investigating the annuli of the 12 wells recently drilled at this location. Present during this inspection were myself, Jon Sassi, Dept EPS, David Schoonover, Dept OGI, Steve Watson, Cabot EH&S Specialist, Marshall McCarty, Cabot Production Person and Prad Jadeja, Cabot consultant. As part of the effort in trying to identify if any of the wells are discharging gas from their respective annular vents, Cabot has developed a more sophisticated layout of the vent pipes which are clearly marked. No E&S violations were noted.
2665011 Primary Facility 2017-11-20 Routine/Complete Inspection No Violations Noted I arrived at the site at 12:24. The weather conditions are mostly cloudy skies, with a light breeze and occasional wind gusts, with temperatures in the mid to upper 30's. Nabors X 36 is the drilling rig on-site. Cabot submitted a Drilling resumption After Break of 30 days or more notification to the Department on 11/15/17 for the Jeffers Farms Pad 2 18H well. The notice indicates the date and time the action was to occur was on 11/16/17 at 6:00 AM. I met with Perk McDowell, site company man, consultant of Cabot. Mr. McDowell informed me of the following regarding site activities. "We are drilling the 18H well on diesel oil based mud at a depth of (6,954) feet. We are drilling below the kickoff point in the curve. Kickoff point (KOP) was at (4,843) feet. Curve will be landed at (8,575) feet. The well will be drilled to total depth (TD) at (18,979) feet. Drilling resumed here on 11/18/17. Surface and intermediate casings have been cemented. The well was drilled to KOP and then the rig left the pad. We resumed
2730550 Primary Facility 2018-05-15 Routine/Complete Inspection No Violations Noted I arrived on site at 1345 to perform a RTNC inspection of the Jeffers Farms P2 well pad. Present during the inspection were Casey Baldwin (WQS - DEP) and Ken Wilson (EHS Foreman - Cabot).

The entrance to the access road was well-marked by the appropriate signage. The access road was stable and solid with no apparent erosion or deterioration. The well's mailbox contained most of the required paperwork, however the site map outlining the BMPs associated with the ESCGP permit was absent. I used the site map with PCSM associated BMPs instead.

On the date of inspection, the wells on the pad were in between stages of hydraulic fracturing. Fracturing had been completed on the 8H, 10H, 12H, 14H, 16H, and 18H. Hydraulic fracturing had yet to be performed on the 7H, 9H, 11H, 13H, 15H, and 17H.

Several nearby water supply complaints have prompted Cabot to install a monitoring station on site to aid in early detection of any further issues that may arise.

The fill slope appeared to be well-vegetated and mostly stab

2741474 Primary Facility 2018-06-12 Routine/Complete Inspection No Violations Noted At time of inspection.

Met with company man Andy Rodriguez. Keane was on site to frac the 12 wells on the location. The even number wells were completed first, for frac information see inspection conducted on 4/17/18. The frac was completed and Keane was rigging down there iron and moving off location when I arrived on location. There were 46 stages completed in the 7H. There were 66 stages completed in the 9H. There were 78 stages completed in the 11H. There were 58 stages completed in the 13H. There were 50 stages completed in the 15H. There were 46 stages completed in the 17H. I took a walk around the location and there were no obvious concerns noticed.

2762365 Primary Facility 2018-08-07 Follow-up Inspection Pending At time of inspection.

The wells were recently completed and put in production. Cabot Oil & Gas contacted the Department to let them know they plan to evaluate and take isotopic samples from the annuli of the Jeffers Farms P2. The Department Eric Rooney (Geologist) and David Schoonover (Oil & Gas inspector) was on-site to observe and document results. We met with Cabot representatives Mike Hall and Ben Whitaker and Selman representatives Tyler Thomas and Kaydee Oliver. Remedial work was done on the 14H, 8H, 7H and 10H wells. Work started in August 2017 and well assessments are still ongoing.

13H 115-22256 All annuli were connected together and venting to a poly vent tank. (9x5) 45% LEL 22500ppm sample taken (13x9) 36% LEL 17100ppm sample taken (20x13) 40% LEL 20000ppm sample taken Since some presence of gas was detected at all wells annuli, it appears that some comingling of gas may have been occurring within the current vent plumbing set up.

2836066 Primary Facility 2019-02-04 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site has good stabilization. No E&S issues identified. No violations noted.
2855448 Primary Facility 2019-03-13 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. Overall the site appears to have good stabilization. As Photo #2 #3 show, a sheen was noted on the containment which is still present from the stimulation activities which occurred at this site. Please vac this containment and remove immediately. Steve Watson, Cabot EH&S Specialist was notified about this sheen during the inspection. No E&S issues identified. No violations noted.
2856403 Primary Facility 2019-03-20 Follow-up Inspection No Violations Noted Today's inspection was conducted as a follow-up inspection to the Department's inspection conducted on 3/13/19 in which an oily sheen was noted on standing water which was on containment present on this pad. Today's inspection finds that the contaminated water was removed, the 3 mobile water tanks have been removed, and the containment is being removed. Standing water thus far exposed after containment removal has no sheen present. No violations noted.

For data sources see[8]

References