If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-115-22262 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.838606,"lon":-75.604128,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Susquehanna | |
| Municipality: Jackson Township | |
| Operator Name: SWN PROD CO LLC | |
| Well Pad ID: 150053 | |
| Farm/Lease Name: PEASE 1H | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2016-11-30 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.838606 | |
| Longitude: -75.604128 |
| Date | Event |
|---|---|
| 2016-11-30 | New Permit Application |
| 2017-05-03 | Performed Spud Operation |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2017-10-11 | 2017-10-17 | 6,883 | 7,857,030 | 0 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | SAND-PREMIUM WHITE-30/50, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 |
| Fresh Water | Listed Above | Hazardous and Non-Hazardous Ingredients | ||||||
| Inorganic salt | Proprietary | 30 | 0.0250027 | 19110 | ||||
| Crystalline silica, quartz | 14808-60-7 | 100 | 13.6107 | 10,402,800.0 | ||||
| Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0250027 | 19110 | ||||
| Organic phosphonate | Proprietary | 60 | 0.0139892 | 10693 | ||||
| Diammonium phosphate | 7783-28-0 | 5 | 0.00116577 | 892 | ||||
| Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00395317 | 3022 | ||||
| Acrylamide acrylate copolymer | Proprietary | 30 | 0.0250027 | 19110 | ||||
| Hydrochloric acid | 7647-01-0 | 15 | 0.0917905 | 70157 | ||||
| Non-hazardous food substance | Proprietary | 100 | 0.000205413 | 158 | ||||
| Ammonium chloride | 12125-02-9 | 30 | 0.00699462 | 5347 | ||||
| Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 0.715463 | 546839 | |
| Water | 7732-18-5 | 100 | 85.631 | 65,448,800.0 | ||||
| SAND-COMMON WHITE - 100 MESH, 3307 LB BAG | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
| HCL >10% | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
| HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
| LP-65 MC | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
| FR-76 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
| BE-9 | Halliburton | Biocide | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2017 | SWN PROD CO LLC | 843,348.00 | 56 | 0.00 | 0 | 0.00 | 0 |
| 2018 | SWN PROD CO LLC | 2,823,538.00 | 359 | 0.00 | 0 | 0.00 | 0 |
| 2019 | SWN PROD CO LLC | 1,284,145.00 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 68.33 Bbl | REUSE (AT WELL PAD) | |
| 2017 | SWN PROD CO LLC | Synthetic Liner Materials | 24.31 Tons | LANDFILL | 101247 |
| 2017 | SWN PROD CO LLC | Soil Contaminated by Oil & Gas Related Spills | 5.29 Tons | LANDFILL | 101247 |
| 2017 | SWN PROD CO LLC | Produced Fluid | 12,104.67 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2017 | SWN PROD CO LLC | Produced Fluid | 1.56 Tons | LANDFILL | 301358 |
| 2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 162.01 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2017 | SWN PROD CO LLC | Soil Contaminated by Oil | 5.29 Tons | LANDFILL | 101247 |
| 2017 | SWN PROD CO LLC | Drill Cuttings | 1,451.71 Tons | LANDFILL | 101247 |
| 2017 | SWN PROD CO LLC | Produced Fluid | 386.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 3,634.01 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 335.33 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 282.65 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2018 | SWN PROD CO LLC | Produced Fluid | 505.01 Bbl | SURFACE IMPOUNDMENT | 826342 |
| 2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 122.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 55.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
| 2019 | SWN PROD CO LLC | Synthetic Liner Materials | 75.00 Tons | LANDFILL | 100933 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 509.58 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 60.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
| 2019 | SWN PROD CO LLC | Produced Fluid | 375.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2591607 | Primary Facility | 2017-05-04 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 11:25a.m. for a new spud inspection.
Minichi Contracting Group was on site to drill and run the conductor pipe for the 1H and 2H with a dual rotary rig. I spoke with driller Ralph Dewald of Minichi, the 2H was drilled and the conductor was set at 50'. The rig was set up to start the 1H, Ralph told me they were waiting for an excavator with a jack hammer attachment because the surface is so hard. The projected TD for the 1H is 88'. The drill cuttings were put into a sealed role off container and hauled to the Keystone Landfill. I took a walk around the location and there were no obvious concerns noticed. I left the site at 12:00p.m. |
| 2604247 | Primary Facility | 2017-06-14 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 8:45a.m.
I met with company man John Hill. W S G Rig #1 was on site and waiting to move to the Leonard pad. A welder was on site and was welding the well head on the 1H. I took a walk around the location and there were no obvious concerns noticed. I left the site at 9:35a.m. |
| 2622891 | Primary Facility | 2017-08-02 | Incident- Response to Accident or Event | Pending | I arrived on site and met with David Schoonover (DEP-OGI) and Mike Deming (SWN). The inspection was halted due to lightening, as the rig was shut down. I arrived at 1:45 PM. Mr. Deming explained the following: At 0730 on 8/1/17 the well site supervisor was conducting an inspection of the site when a few associates were washing dust from a telehandler. They were using a substance they called "rig wash." The well site supervisor discovered water on the pad when the remainder of the pad was dry. Water was pooled in an area outside of the containment. Ryan Klemish later arrived and tested some ponded water, for conductivity, on the site and found it was 2.3 mS. The well site supervisor scraped the surface of the site removing 3 buckets worth of material from the surface, which is an estimated 2-3 cu yards of material. Seth Tratthen conducted soil EC screenings after the area was excavated to determine if the release was remediated. His conductivity readings were all under 220 micro siemens. He to |
| 2622993 | Primary Facility | 2017-08-03 | Follow-up Inspection | Violation(s) Noted | Jon Sassi (DEP-EPS) and I met with Joseph Pendergraft (Company Man- Bedrock, SWN) and Mike Deming (Senior Regulatory Analyst-SWN). I inquired about the capacity of the power washer and Mr. Pendergraft explained that the rig wash and water is mixed at an approximate rig wash to water ratio of 1:4 in a 5 gallon bucket. They hand washed the telehadler then sprayed it down with a power washer. When I inquired about a total volume of fluid used during this practice, Mr. Pendergraft stated "I have no quantitative value that I can give you on that". Three (3) 500 bbl gallon tanks situated on Durabase Newpark mats were being drained while we were on site. They will then remove the tanks and pull back the containment. Crews were on site vacuuming up fluid on the containment, patching holes, and working on draining the tanks.
Mr. Sassi collected conductivity readings on the well pad that ranged from 0.8-3.0 mS. The rig wash soap, Smartwash 20, was stored in a tote on containment. Mr. Sassi collected pure pr |
| 2624143 | Primary Facility | 2017-08-07 | Drilling/Alteration | No Violations Noted | At time of inspection, arrived on site at 15:00p.m.
I met with company man Joseph Pendergraft. SDC Rig #44 was on site to drill the lateral section of the well. The top-hole section of the well was drilled and completed on 6/14/17 by WSG Rig#1 to the depth of 1635'. There was approximately 20 gallons of oil based mud spilled onto the secondary containment from the shakers at 13:00p.m. There were no signs of oil based mud off the containment at time of inspection. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 8,343' Proposed depth of the well |
| 2630223 | Primary Facility | 2017-08-29 | Incident- Response to Accident or Event | Violation(s) & Outstanding Violations | The Department arrived on site in response to the self-reported release of a Smartwash 20/water mixture. Eric Rooney (P.G.) and I met with Mike Deming (SWN) to conduct an Incident Inspection. Upon our arrival, a vacuum truck had less than a 1 gallon release of antifreeze that they were removing from the well pad surface. Well Services Group was on site as the cleaning contractor and Resource Environmental was on site to delineate the release.
According to Mr. Deming, on 8/26/17 he received a call concerning water coming from underneath the containment on the Pease Pad. It was reported to him that they were unable to find any water on the containment, therefore they initially believed it to be water that was under the containment from condensation or a precipitation event that expressed itself while they were moving equipment off. Mr. Deming stated that he arrived on 8/27/17 and identified the area in Photo #1 which was field tested with an approximate 2 mS conductivity. He later spoke to Steve Moy |
| 2633407 | Primary Facility | 2017-08-30 | Follow-up Inspection | Outstanding Violations - Viols Req'd | The Department was on site to conduct a Follow Up Inspection, in response to a notification that SWN was removing the on site containment, of the RU 62 site. We met with Mike Deming (Senior Regulatory Analyst-SWN) Resource Environmental, their remediation contractor, found some black staining under the containment and they are collecting soil samples in bags to conduct headspace sampling. It was estimated under 5 gallons. The Department requested that they have Resource Environmental walk the fill slope to search for seeps. |
| 2648807 | Primary Facility | 2017-10-18 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
I met with company man Wesley Martinez. Halliburton was on site to frac the 1H and 2H wells. The 1H was completed and the crew was changing the iron over to the 2H. The water was being pumped in from the Young fresh water impoundment. It is being pumped into a 20,000bbl tank on site. I took a walk around the location and there were no obvious concerns noticed. There were no violations noticed. |
| 2670450 | Primary Facility | 2017-12-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
| 2736018 | Primary Facility | 2018-05-29 | Routine/Complete Inspection | No Violations Noted | Today's inspection was conducted as a routine inspection. No E&S issues were identified. No violations noted. |
| 2768916 | Primary Facility | 2018-08-29 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 3' below grade in the cellar with no bubbling noticed and there was no gas detected in the remainder of the cellar. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2622993 | 793497 | 2017-08-07 | CSL 402(b) | Environmental Health & Safety | Elevated conductivity readings were found both on containment and on the well pad surface. | |
| 2622993 | 793498 | 2017-08-07 | SWMA 301 | Environmental Health & Safety | The mixture impacted the pad surface. | |
| 2622993 | 793499 | 2017-08-07 | 78.56(a) | Environmental Health & Safety | A water/Smartwash 20 mixture traveled off containment and onto the well site surface. | |
| 2630223 | 795834 | 2017-08-29 | 2017-08-29 | CSL 402(b) | Environmental Health & Safety | The Smartwash 20 rig wash /water mixture impacted the surface of the well pad. |
| 2630223 | 795835 | 2017-08-29 | 2017-08-29 | SWMA 301 | Environmental Health & Safety | The substance impacted the surface of the well site. |
| 2630223 | 795836 | 2017-08-29 | 2017-08-29 | 78a56(a) | Environmental Health & Safety | The release was not contained. |
| 2633407 | 796593 | 2017-08-30 | SWMA 301 | Environmental Health & Safety | The mixture impacted the pad surface and was documented in the Department's 8/29/17 inspection. | |
| 2633407 | 796594 | 2017-08-30 | CSL 402(b) | Environmental Health & Safety | A Smartwash 20/ water mixture was released previously to the surface of the well site. | |
| 2633407 | 796595 | 2017-08-30 | 78.56(a) | Environmental Health & Safety | A water/Smartwash 20 mixture traveled off containment and onto the well site surface as detailed in the Department's 8/29/17 inspection. |
| Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
|---|---|---|---|---|---|---|---|
| 795834 | 357858 | NOV - Notice of Violation | 2017-08-29 | ||||
| 795835 | 357858 | NOV - Notice of Violation | 2017-08-29 | ||||
| 795836 | 357858 | NOV - Notice of Violation | 2017-08-29 |
For data sources see[8]