X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-115-22271

Well Details

Well ID: 37-115-22271
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Franklin Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 147179
Farm/Lease Name: BOLLES NW 1H
License Status:
Spud Date: 2017-03-25
Permit Date: 2017-02-23
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.896633
Longitude: -75.818608

For data sources see[1][2][3]

Well History

Date Event
Deviated
2017-02-23 New Permit Application
2017-03-24 Performed Spud Operation
2017-05-15 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-06-21 2017-07-22 6,312 13,145,700 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
Ingredients Listed Above Listed Above Water 7732-18-5 100 0.581741 743060
HAI-150E Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
Diammonium phosphate 7783-28-0 5 0.00113669 1452
Acrylamide acrylate copolymer Proprietary 30 0.0259964 33206
Organic phosphonate Proprietary 60 0.0136403 17423
Crystalline silica, quartz 14808-60-7 100 13.1292 16,770,000.0
Hydrotreated light petroleum distillate 64742-47-8 30 0.0259964 33206
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00361404 4617
Ammonium chloride 12125-02-9 30 0.00682013 8712
Hydrochloric acid 7647-01-0 15 0.0719951 91959.5
Non-hazardous food substance Proprietary 100 0.00012135 155
Inorganic salt Proprietary 30 0.0259964 33206
Fresh Water Operator Base Fluid Water 7732-18-5 100 86.2452 110,161,000.0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
BE-9 Halliburton Biocide Listed Below Listed Below 0 0 0
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
LP-65 MC Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 SWN PROD CO LLC 1,014,087.00 122 0.00 0 0.00 0
2018 SWN PROD CO LLC 1,666,757.00 331 0.00 0 0.00 0
2019 SWN PROD CO LLC 1,127,090.00 361 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 SWN PROD CO LLC Synthetic Liner Materials 25.79 Tons LANDFILL 101247
2017 SWN PROD CO LLC Unused Fracturing Fluid Waste 46.98 Tons LANDFILL 100933
2017 SWN PROD CO LLC Produced Fluid 54,526.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 62.05 Tons LANDFILL 301358
2017 SWN PROD CO LLC Produced Fluid 183.34 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Drilling Fluid Waste 300.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Unused Fracturing Fluid Waste 1,132.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Other Oil & Gas Wastes 214.34 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drill Cuttings 4,767.49 Tons LANDFILL 101247
2017 SWN PROD CO LLC Synthetic Liner Materials 2.35 Tons LANDFILL 100933
2017 SWN PROD CO LLC Produced Fluid 36.67 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWN PROD CO LLC Produced Fluid 17,286.67 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 22.48 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 2,258.67 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 4,195.34 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 473.16 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 41.67 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Other Oil & Gas Wastes 88.92 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Other Oil & Gas Wastes 198.33 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Synthetic Liner Materials 3.00 Tons LANDFILL 100933
2019 SWN PROD CO LLC Produced Fluid 5,388.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 802.66 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 2,057.00 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 356.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2557740 Primary Facility 2017-01-03 Preoperation Inspection No Violations Noted The Department was on site at the Bolles South Well Site to conduct a Preoperational Inspection. The Department met on site with Rich Gulyas and Seth Tratthen (SWN). At the time of the inspection, the site was covered in snow.

S. Moyer conducted a Post Weather Inspection on 12/7/16 and he documented that no attention was needed.

The Department walked the site with the above mentioned individuals and determined that it appears as though the perimeter BMP's have been installed.

2576686 Primary Facility 2017-03-27 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 9:05a.m. for a new spud inspection.

Minichi Contracting Groups equipment was on site. I spoke with welder Mylo Welter of Minichi, the conductor pipe was drilled and set to a depth of 88' with a dual rotary rig. The drill cuttings are in sealed role off containers and will be hauled to the Keystone Landfill. I took a walk around the location and there were no obvious concerns noticed. I left the site at 9:25a.m.

2581099 Primary Facility 2017-04-10 Drilling/Alteration No Violations Noted At time of inspection, arrived on site at 11:00a.m.

I met with company man Robert Gray. W S G Rig #1 was on site and waiting the mandatory 8hrs on cement until 1:15p.m. I took a walk around the location and there were no obvious concerns noticed. Depth at time of inspection was 1650'. I left the site at 12:05p.m.

2613958 Primary Facility 2017-07-10 Routine/Complete Inspection No Violations Noted At time of inspection, arrived on site at 13:10p.m.

I met with company men Aron Lash and Chris Henry. Halliburton was on site to stimulate the 1H,2H, and 3H wells. They completed stage 17 out of 56 stages on the 2H and were waiting for some packing repairs before starting stage 18. The 1H had 40 stages completed out of 42 stages. The 3H hasn’t been started yet but will have 88 stages when completed. The water was being hauled to the site from the Zeffer production water impoundment and Odell fresh water impoundment. I took a walk around the location and there were no obvious concerns noticed. I left the site at 13:40p.m.

2653314 Primary Facility 2017-10-27 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was recently completed and put in production. The well tag was on the well and correct. There were 22 500bbl frac tanks on site and on containment. The tanks were empty and the containment appeared to be in good condition. I took a walk around the location and there were obvious concerns noticed. There were no violation noted.

2755847 Primary Facility 2018-07-25 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a corrugated pipe around the well for inspection access. The cellar was full of water and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2856958 Primary Facility 2019-03-21 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. There was an empty 500bbl tank on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[8]

References