Well Details

Well ID: 37-115-22283
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: New Milford Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 147284
Farm/Lease Name: ENDLESS MOUNTAIN RECREATION
License Status: Active
Spud Date: 2017-02-28
Permit Date: 2017-02-16
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.865768
Longitude: -75.783856

For data sources see[1][2][3]

Well History

Date Event
2017-02-16 New Permit Application
2017-02-28 Performed Spud Operation
2017-10-03 MOD

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-01-28 2018-02-17 6,673 7,062,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Ingredients Listed Above Listed Above Water 7732-18-5 100 1.36199 935690
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) Halliburton Proppant Listed Below Listed Below 0 0 0
LCA-1 Halliburton Solvent Listed Below Listed Below 0 0 0
Fresh Water Operator Base Fluid Water 7732-18-5 100 85.5682 58,785,500.0
SAND-PREMIUM WHITE-30/50, BULK Halliburton Proppant Listed Below Listed Below 0 0 0
HAI-150E Halliburton Corrosion Inhibitor Listed Below Listed Below 0 0 0
FR-76 Halliburton Friction Reducer Listed Below Listed Below 0 0 0
LP-65 MC Halliburton Scale Inhibitor Listed Below Listed Below 0 0 0
HYDROCHLORIC ACID Halliburton Solvent Listed Below Listed Below 0 0 0
BE-9W Halliburton Biocide Listed Below Listed Below 0 0 0
Hdrotreated light petrolem distillates Proprietary 100 0.00106957 735
Acrylamide acrylate copolymer Proprietary 30 0.030635 21047
Propylene glycol 57-55-6 60 0.0465359 31972
Hydrotreated light petroleum distillate 64742-47-8 30 0.030635 21047
Ammonium chloride 12125-02-9 30 0.00694384 4771
Non-hazardous food substance Proprietary 100 0.000924306 635
Inorganic salt Proprietary 30 0.030635 21047
Hydrochloric acid 7647-01-0 15 0.18139 124616
Organic phosphonate Proprietary 60 0.0138877 9541
Tributyl tetradecyl phosphonium chloride 81741-28-8 10 0.00775598 5330
Crystalline silica, quartz 14808-60-7 100 13.0565 8,969,830.0
Diammonium phosphate 7783-28-0 5 0.00115731 796

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 SWN PROD CO LLC 0.00 0 0.00 0 0.00 0
2018 SWN PROD CO LLC 2,895,442.00 298 0.00 0 0.00 0
2019 SWN PROD CO LLC 1,871,741.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 SWN PROD CO LLC Other Oil & Gas Wastes 44.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Synthetic Liner Materials 12.73 Tons LANDFILL 101247
2017 SWN PROD CO LLC Drilling Fluid Waste 88.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Produced Fluid 107.66 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drilling Fluid Waste 128.00 Bbl REUSE (AT WELL PAD)
2017 SWN PROD CO LLC Other Oil & Gas Wastes 324.20 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2017 SWN PROD CO LLC Drill Cuttings 1,267.64 Tons LANDFILL 101247
2018 SWN PROD CO LLC Produced Fluid 21,556.55 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Unused Fracturing Fluid Waste 9.62 Tons LANDFILL 100933
2018 SWN PROD CO LLC Other Oil & Gas Wastes 22.00 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Other Oil & Gas Wastes 24.80 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 129.86 Tons LANDFILL 301358
2018 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 7.00 Tons LANDFILL 101247
2018 SWN PROD CO LLC Produced Fluid 16,480.75 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Produced Fluid 2,102.40 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.02 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 SWN PROD CO LLC Produced Fluid 100.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWN PROD CO LLC Other Oil & Gas Wastes 120.80 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Waste Water Treatment Sludge 4.45 Tons LANDFILL 301358
2018 SWN PROD CO LLC Synthetic Liner Materials 37.00 Tons LANDFILL 101247
2018 SWN PROD CO LLC Soil Contaminated by Oil 0.02 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2018 SWN PROD CO LLC Soil Contaminated by Oil 7.00 Tons LANDFILL 101247
2018 SWN PROD CO LLC Unused Fracturing Fluid Waste 7.34 Tons LANDFILL 301358
2018 SWN PROD CO LLC Filter Socks 0.09 Tons RESIDUAL WASTE PROCESSING FACILITY 301280
2019 SWN PROD CO LLC Other Oil & Gas Wastes 30.70 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 235.80 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Produced Fluid 1,737.40 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 44.00 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Produced Fluid 4,683.80 Bbl SURFACE IMPOUNDMENT 95-16-65420-013

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2649214 Primary Facility 2017-10-18 Routine/Complete Inspection Viol(s) Noted & Immediately Corrected At time of inspection.

Met with company man Tom Howard. While conducting a rig inspection for the 1H, I noticed the conductor pipe was set for the 7H. Tom said it was drilled and set on 2/28/17. After checking the Department records, it was found that a spud notification was never received for the 7H. I contacted Steve Moyer of SWN to see if they could supply the Department with any documentation of a spud notice. Steve said he couldn't find where a notice was sent. SWN did send a late spud notice to the Department on 10/19/17.

2654454 Primary Facility 2017-10-31 Drilling/Alteration No Violations Noted At time of inspection.

Met with company man Tom Howard. SDC 44 was on site and drilling the hole for the production casing. The proposed TD for the well is 12816'. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2660173 Primary Facility 2017-11-07 Routine/Complete Inspection No Violations Noted I arrived at the site at 12:18 in response to a reported spill of (15) gallons of rainwater. Mike Deming, Senior Regulatory Analyst of SWNPC informed me of the spill on 11/6/17. The weather conditions are cloudy skies, calm winds with temperatures in the mid 30's. I met with Dillon Otten, Regulatory Technician and Dan Hessdorfer, site company man, consultant, both of SWNPC. SDC #44 is the rig on the location. Mr. Hessdorfer stated the following in reference to the spill and site activities. "The Endless Mt. Rec 7H well has just been drilled to total depth at (12,848) feet. Diesel oil based mud was used during drilling when the spill occurred. The production casing will be cemented tomorrow. The rig move will start Monday. The rig will go to the Humbert (Range Unit 9) pad. The spill occurred on 11/4/17 at 6:45 AM. The trackhoe hand (operator) discovered the spill and reported it to me and then I reported it to Mr. Deming. The truck picked up the container full of drill cuttings. Rainwater between the liner in
2684054 Primary Facility 2018-01-08 Routine/Complete Inspection No Violations Noted At time of inspection.

Met with company man Eddie New. Halliburton was on site to frac the 1H, 2H, 3H and 7H wells. They were on the first stage out of 53 stages on the 2H at time of inspection. The 3H was completed with 52 stages. The 1H and 7H haven't been started, the 1H will have 56 stages and the 7H will have 23 stages when they are completed. The water is being pumped to the site from the Zeffer production water impoundment and the Young and Odell fresh water impoundments. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2685307 Primary Facility 2018-01-18 Routine/Complete Inspection No Violations Noted Today's inspection was conducted as a routine inspection. No leaks were detected during this inspection around the temporary water tank and associated water lines. Photo's 4 and 5 show the external water level read out attached to the water tank. No E&S issues identified during the inspection. No violations noted.
2695584 Primary Facility 2018-02-16 Complaint Inspection No Violations Noted At time of inspection.

The Department received a complaint on 2/16/18 that the entrance sign is missing for the Endless Mountain Recreation well site. The sign is at the entrance of the Endless Mountain Recreation site on Wolfs Lair Rd. Wolfs Lair Rd in off of Route 706. There is no road sign at the beginning of the road. The coordinates on the sign is correct for where the sign is placed. There were no violations noted.

2707395 Primary Facility 2018-03-01 Incident- Response to Accident or Event No Violations Noted I arrived at the site at 12:50. The weather conditions are cloudy skies, with temperatures in the mid 40's and a light breeze. On 2/26/18 Chuck Rogers, Solid Waste Supervisor in the Waste Management Program of the PADEP Northeast Regional Office in Wilkes-Barre, PA contacted Steve Moyer, Regulatory Supervisor of SWN regarding a waste container from this pad transported to Keystone Landfill in Dunmore, PA in attempt for disposal, setting off an alarm at the landfill for Technologically Enhanced Normally Occurring Radioactive Material (TENORM) on 2/23/18. Mr. Moyer forwarded an email response in reference to the container with elevated levels of TENORM to Mr. Rogers on 2/26/18 at 9:38 AM. Mr. Moyer stated the following in the email. "Thanks for the call this morning regarding our containment waste at KSL. Some details about the origin of the load are below. Also attached is a copy of our approved OG-71b permit issued by the state. Jon Sassi was the SWS who inspected the tank prior to commissioning. The OG-71b
2717759 Primary Facility 2018-03-28 Follow-up Inspection No Violations Noted I arrived at the site at 13:20 to conduct a follow up inspection due to the discovery of a potential fluid spill at the site during an inspection conducted by the Department on 3/1/18, inspection ID #2706377. The weather conditions were cloudy skies with dense fog, a slight breeze and temperatures in the 40's. Based upon my findings at the site on 3/1/18, I planned on returning to conduct additional monitoring. I had requested that SWN conduct an investigation of the potentially impacted area on the pad surface as indicated in the 3/1/18 inspection report. For additional details pertaining to the discovery of the potential fluid spill during the 3/1/18 inspection report, refer to the inspection number mentioned above. For additional details pertaining to the cleaning of the Modular Above Storage Structure (MASS) liners which set off a radiation alarm at Keystone Landfill in Dunmore, PA on 2-23-18, refer to the Department's 3/1/18 inspection report, Inspection ID # 2706389.

Mike Deming, Senior Regulatory A

2732499 Primary Facility 2018-05-14 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was recently completed and put in production. The well tag was on the well and correct. The cellar was set up with a corrugated pipe around the well for inspection access. The (20x13) and (13x9) annuli were below the water level and there was no bubbling noticed. There were nine 500bbl tanks on containment and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2830672 Primary Facility 2019-01-23 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was in production. The cellar was set up with a plastic corrugated pipe around the well for inspection access. The cellar was full of water and there was no bubbling noticed. There was a 500bbl tank on snow covered containment, what wasn't covered appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2649214 799512 2017-10-18 2017-10-18 OGA3211(F1) Administrative

For data sources see[8]