If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-115-22379 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.865681,"lon":-75.682017,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Susquehanna | |
Municipality: New Milford Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 145772 | |
Farm/Lease Name: WOOSMAN 4H | |
License Status: | |
Spud Date: 2018-01-19 | |
Permit Date: 2017-10-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.865681 | |
Longitude: -75.682017 |
Date | Event |
---|---|
Deviated | |
2017-10-30 | New Permit Application |
2018-01-19 | Performed Spud Operation |
2018-06-06 | Drilling Completion |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-07-04 | 2018-07-15 | 6,316 | 5,401,030 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | WFRA-2000 | U.S. Well Services, LLC | Friction Reducer | Water | 7732-18-5 | 60 | 0.061022 | 32766.2 |
Hydrated light distillate (petroleum) | 64742-47-8 | 30 | 0.025019 | 13434.1 | ||||
2-Propenoic acid, polymer with 2 propenamide | 9003-06-9 | 30 | 0.030511 | 16383.1 | ||||
K-BAC 1005 | U.S. Well Services, LLC | Anti-Bacterial Agent | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 5.76 | 0.001675 | 899.55 | |
Water | 7732-18-5 | 44.3 | 0.005257 | 2822.69 | ||||
Polyethylene Glycol | 25322-68-3 | 50 | 0.006645 | 3568.19 | ||||
HCL Acid (12.6%-17.5%) | U.S. Well Services, LLC | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 17.5 | 0.238368 | 127992 | |
Water | 7732-18-5 | 87.4 | 1.02525 | 550509 | ||||
LT FLUSH SYSTEM I | U.S. Well Services, LLC | Other | Mineral oil, petroleum distillates, hrdotreated light naphthenic |
64742-53-6 | 100 | 0.00026 | 139.445 | |
AI-303 | U.S. Well Services, LLC | Acid Corrosion Inhibitors | Butyl cellosolve | 111-76-2 | 20 | 0.000106 | 57.109 | |
Acetophenone,thiourea,formaldehyde polymer | 68527-49-1 | 5 | 0.00003000 | 15.846 | ||||
Formic acid | 64-18-6 | 20 | 0.000118 | 63.384 | ||||
Polyether | 60828-78-6 | 10 | 0.00005900 | 31.692 | ||||
Ethylene glycol | 107-21-1 | 40 | 0.000338 | 181.278 | ||||
Cinnamaldehyde | 104-55-2 | 20 | 0.000122 | 65.5391 | ||||
Water | Southwestern Energy | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 83.8893 | 45,044,600.0 | |
Sand | U.S. Well Services, LLC | Proppant | Crystalline Silica, quartz | 14808-60-7 | 100 | 14.7147 | 7,901,100.0 | |
SI-1200s | U.S. Well Services, LLC | Scale Inhibitor | Proprietary Scale Inhibitor | Proprietary | 10 | 0.001186 | 636.704 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2018 | SWN PROD CO LLC | 966,331.00 | 147 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 1,448,436.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 1,094.83 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 132.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 1,970.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 12,277.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Drill Cuttings | 16,550.03 Tons | LANDFILL | 101247 |
2018 | SWN PROD CO LLC | Produced Fluid | 539.80 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 176.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWN PROD CO LLC | Synthetic Liner Materials | 9.24 Tons | LANDFILL | 100933 |
2018 | SWN PROD CO LLC | Filter Socks | 0.10 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2019 | SWN PROD CO LLC | Produced Fluid | 666.13 Bbl | SURFACE IMPOUNDMENT | 826342 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 40.23 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 2,944.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 88.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Produced Fluid | 20.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2686184 | Primary Facility | 2018-01-19 | Drilling/Alteration | No Violations Noted | At time of inspection.
On site for a new spud inspection. Minichi Contracting Group was on site to drill and run the conductor pipe for the 1H, 2H, 3H, 4H, and 5H wells. I met with driller Ralph Dewald. The rig was on the 4H at a depth of 75'. The 2H was completed at a depth of 180'. The 3H was completed at a depth of 176'. The 5H was completed at a depth of 175'. They plan to drill the 1H when the 4H is completed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2700836 | Primary Facility | 2018-03-05 | Drilling/Alteration | No Violations Noted | At time of inspection.
Met with company man Johnny Hale. Falcon 24 was on site to drill the top-hole section of the well. Proposed TD for the top-hole section is 5050'. They drilled out the shoe of the intermediate casing and was performing there fit test below the casing. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2737484 | Primary Facility | 2018-06-05 | Drilling/Alteration | No Violations Noted | At time of inspection.
Met with company man Andrew Griffith. SDC45 was on site and drilling the lateral section of the well. They are drilling with DOBM. Proposed TD for the well is 11,426'. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2740239 | Primary Facility | 2018-06-12 | Follow-up Inspection | No Violations Noted | On 6/11/18 at 3:55pm, I received a phone call from Mike Deming of SWN that there was bubbling noticed at the (13x9) annulus of the Wooseman 4H well.
At time of inspection. I met with Dillon Otten of SWN. We noticed slight bubbling at the (13x9) annulus. Dillon showed me a video of the bubbling taken on 6/8/18, the bubbling was steady in the video and appeared to have diminished by the time of my inspection. We filled the annular space with water to the top of the casing. There was no gas detected with my Altair 5X gas meter, last calibration was 6/7/18. I suggested SWN monitor the well and contact the Department if the bubbling increases and Dillon agreed. There were no violations noted. |
2751793 | Primary Facility | 2018-07-13 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
Met with company man Kyle Wilkins. US Well Service was on site to frac the 1H, 2H, 3H and 4H wells. They were on stage 19 out of 25 on the 1H and running a plug and perf in the 3H when I arrived. There were 15 stages completed out of 24 on the 2H. There were 18 stages completed out of 26 on the 3H. There were 15 stages completed out of 20 on the 4H. The water was being pumped to the location from the Zeffer production fluid impoundment and the Young fresh water impoundment. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
2753556 | Primary Facility | 2018-07-16 | Routine/Complete Inspection | No Violations Noted | I performed an RTNC inspection in conjunction with Jon Sassi at the Woosman well pad. The wells associated with this pad are the 115-21054, 115-22377, 115-22402, 115-22378, 115-22403, 115-22379. The well site was being fracked at the time of inspection, The company man was Mark McPherson.
The site had good growth and was solid and stable at the time of inspection. There were no erosional issues noted with the site at the time of inspection. There were no violations noted |
2760416 | Primary Facility | 2018-07-20 | Follow-up Inspection | No Violations Noted | The Department was on site to conduct a follow up investigation of a spill that occurred on 7/13/2018. Present representing the Department were Frank Hoehle (WQS) and myself. We arrived on site at 1215 hours.
We talked to Donnie Torres (Well Site Supervisor-SWN). He informed us that crews were setting up on site to perform drill out and flowback operations. The one producing well on the pad was shut in. The others have been fully drilled and stimulated. Drill out operations on the plugs had not yet began. The release occurred on the southwest corner of the pad, when a blender and its associated piping failed, causing a release of production fluid and freshwater in containment. The estimated release volume is not known. Material in the immediate area under the containment was screening high for conductivity. The material was excavated, but more high-conductivity water kept infiltrating the sump area below the containment. At the time of the initial response inspection, it did not appear as if there were a |
2785333 | Primary Facility | 2018-10-05 | Routine/Complete Inspection | No Violations Noted | At time of inspection.
The well was recently completed and put in production. The well tag was on the well and correct. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water .5' below grade in the cellar and there was no bubbling noticed. There were twenty 500bbl frac tanks on containment from a recent frac. Most of the tanks were empty and the containment appeared to be in good condition. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted. |
For data sources see[8]