37-115-22512

Well Details

Well ID: 37-115-22512
Loading map...
Country: United States
State: Pennsylvania
County: Susquehanna
Municipality: Franklin Township
Operator Name: SWN PROD CO LLC
Well Pad ID: 150595
Farm/Lease Name: MITCHELL SOUTH 1H
License Status:
Spud Date: 2018-07-02
Permit Date: 2018-05-31
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.904758
Longitude: -75.838253

For data sources see[1][2][3]

Well History

Date Event
Deviated
2018-05-31 New Permit Application
2018-07-01 Performed Spud Operation
2018-07-03 MOD
2018-08-16 Drilling Completion

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-09-28 2018-10-25 5,952 18,889,400 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 K-BAC 1005 U.S. Well Services, LLC Anti-Bacterial Agent Polyethylene Glycol 25322-68-3 50 0.00672 12273.8
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 5.76 0.001694 3094.26
Water 7732-18-5 44.3 0.005316 9709.46
LT FLUSH SYSTEM I U.S. Well Services, LLC Other Mineral oil, petroleum distillates,
hrdotreated light naphthenic
64742-53-6 100 0.000309 565.118
SI-1200s U.S. Well Services, LLC Scale Inhibitor Proprietary Scale Inhibitor Proprietary 10 0.001241 2266.39
Sand U.S. Well Services, LLC Proppant Crystalline Silica, quartz 14808-60-7 100 12.256 22,385,500.0
HCL Acid (5% to 7.5%) U.S. Well Services, LLC Bulk Acid Water 7732-18-5 95 0.951634 1,738,150.0
Hydrogen Chloride 7647-01-0 7.5 0.087237 159337
AI-303 U.S. Well Services, LLC Acid Corrosion Inhibitors Formic acid 64-18-6 20 0.00008000 145.95
Butyl cellosolve 111-76-2 20 0.00007200 131.501
Polyether 60828-78-6 10 0.00004000 72.975
Acetophenone,thiourea,formaldehyde polymer 68527-49-1 5 0.00002000 36.4875
Ethylene glycol 107-21-1 40 0.000229 417.417
Cinnamaldehyde 104-55-2 20 0.00008300 150.912
Water Southwestern Energy Carrier/Base Fluid Water 7732-18-5 100 86.2515 157,538,000.0
WFRA-2000 U.S. Well Services, LLC Friction Reducer Water 7732-18-5 60 0.06147 112275
Hydrated light distillate (petroleum) 64742-47-8 30 0.025203 46032.6
2-Propenoic acid, polymer with 2 propenamide 9003-06-9 30 0.030735 56137.4
HCL Acid (12.6%-17.5%) U.S. Well Services, LLC Bulk Acid Hydrogen Chloride 7647-01-0 17.5 0.060435 110385
Water 7732-18-5 87.4 0.25994 474778

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 SWN PROD CO LLC 704,342.00 38 0.00 0 0.00 0
2019 SWN PROD CO LLC 4,325,876.00 356 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 SWN PROD CO LLC Produced Fluid 6,799.82 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 91.67 Bbl SURFACE IMPOUNDMENT 826342
2018 SWN PROD CO LLC Synthetic Liner Materials 32.00 Tons LANDFILL 100933
2018 SWN PROD CO LLC Produced Fluid 11,498.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Produced Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 SWN PROD CO LLC Other Oil & Gas Wastes 6,628.97 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Other Oil & Gas Wastes 20.00 Bbl REUSE (AT WELL PAD)
2018 SWN PROD CO LLC Drilling Fluid Waste 1,992.00 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2018 SWN PROD CO LLC Drill Cuttings 1,661.28 Tons LANDFILL 101247
2018 SWN PROD CO LLC Produced Fluid 55.00 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Produced Fluid 2,487.99 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Other Oil & Gas Wastes 636.82 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 140.84 Bbl REUSE (AT WELL PAD)
2019 SWN PROD CO LLC Other Oil & Gas Wastes 42.17 Bbl SURFACE IMPOUNDMENT 826342
2019 SWN PROD CO LLC Synthetic Liner Materials 70.24 Tons LANDFILL 100933
2019 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 14.00 Tons LANDFILL 100933
2019 SWN PROD CO LLC Soil Contaminated by Oil 14.00 Tons LANDFILL 100933
2019 SWN PROD CO LLC Produced Fluid 326.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC035
2019 SWN PROD CO LLC Synthetic Liner Materials 37.00 Tons LANDFILL 101247
2019 SWN PROD CO LLC Produced Fluid 10,532.83 Bbl SURFACE IMPOUNDMENT 95-16-65420-013
2019 SWN PROD CO LLC Produced Fluid 15.60 Tons LANDFILL 301358
2019 SWN PROD CO LLC Soil Contaminated by Oil & Gas Related Spills 0.77 Tons RESIDUAL WASTE PROCESSING FACILITY 301333
2019 SWN PROD CO LLC Soil Contaminated by Oil 0.77 Tons RESIDUAL WASTE PROCESSING FACILITY 301333

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2747755 Primary Facility 2018-07-02 Drilling/Alteration No Violations Noted At time of inspection.

Minichi Contracting Group was on site to drill and set the conductor pipe on the 1H and 2H wells. I met with Minichi driller Keith Bowman. The 1H was completed at a depth of 88'. They were at 60' on the the 2H and plan to TD at 88'. The drill cuttings are put in roll off containers and hauled to the Keystone landfill. I took a walk around the location and there were no obvious concrns noticed. There were no violations noted.

2760280 Primary Facility 2018-07-30 Routine/Complete Inspection No Violations Noted I inspected the Mitchell well pad on 07/30/2018 in response to a spill notification.

I met with company man Tommy Howard on site to perform an inspection. There apparently had been communication between the well bore and the mousehole which was discovered when a righand stepped on the plastic surrounding the hole and discovered it was puffed up with water. The water went back down shortly thereafter and there was no residual water after that initial discovery. The company had just started pumping cement and was just getting returns when it was discovered. The company is currently drilling on the Mitchell 1h. When the incident was noticed they had been running 13 3/8" surface casing which was just finished being flushed out with fresh water.


When the rig moves off, the site will be checked out after the plastic is removed and screened for contamination according to the company man.

The cut and fill slopes are well vegetated and stable.

The access road looked a bit weathered due to heavy traffic b

2760744 Primary Facility 2018-08-06 Drilling/Alteration No Violations Noted At time of inspection.

Met with company man Tommy Howard. SDC 44 was on site and drilling the vertical section of the well. They are drilling with air to 5650'. There are four existing wells on site that are still in production. There are two new wells to be drilled, they are on the first of the two wells. The proposed TD for the well is 17547'. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2783754 Primary Facility 2018-10-03 Routine/Complete Inspection No Violations Noted At time of inspection.

Met with company man Aron Lash. USWS was on site to frac the 1H and 2H wells. The were running a plug and perf in the 1H and stimulating stage 15 on the 2H when I arrived on location. There were 15 out of 75 stages completed on the 1H. There were 14 out of 94 stages completed on the 2H. The water was be pumped from the Odell fresh water impoundment to the NR3 pad then trucked to the HDK pad, from there it was being pumped to the frac site and production water was being trucked directly to the frac site. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

2837791 Primary Facility 2019-02-08 Routine/Complete Inspection No Violations Noted At time of inspection.

The well was recently completed and put in production. The permit numbers on the entrance sign were correct. The well tag was on the well and correct. There was containment around the well and made inspection of the cellar limited. The cellar was set up with a plastic corrugated pipe around the well for inspection access. There was water 2' below grade in the cellar and there was no bubbling noticed. I took a walk around the location and there were no obvious concerns noticed. There were no violations noted.

For data sources see[8]