37-117-20001

Well Details

Well ID: 37-117-20001
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Clymer Township
Operator Name:
Well Pad ID:
Farm/Lease Name: FRANK S BURDICK N-500S
License Status: ACTIVE
Spud Date:
Permit Date: 1995-04-24
Well Type: STORAGE WELL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.880334
Longitude: -77.511177

For data sources see[1][2][3]

Well History

Date Event
1956-07-27 Performed Spud Operation
1956-10-04 Drilling Completion
1956-11-09 NEWLY DRILLED
1995-04-24 New Permit Application
1995-05-20 Drilling Completion
1995-07-31 Perforation
1996-12-05 DRILLED DEEPER

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2003 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2006 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2007 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2008 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2009 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2010 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2011 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2012 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2013 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2014 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2015 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2016 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2017 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0
2018 DOMINION ENERGY TRANS INC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1052878 Primary Facility 2001-08-09 Routine/Complete Inspection No Violations Noted
1070850 Primary Facility 2001-10-25 Routine/Complete Inspection No Violations Noted
1180291 Primary Facility 2002-10-28 Routine/Complete Inspection No Violations Noted
1278386 Primary Facility 2003-10-09 Routine/Complete Inspection No Violations Noted
1495663 Primary Facility 2005-11-14 Routine/Complete Inspection No Violations Noted
1584494 Primary Facility 2006-12-05 Routine/Complete Inspection No Violations Noted
1669491 Primary Facility 2007-11-27 Routine/Complete Inspection No Violations Noted
1752259 Primary Facility 2008-11-17 Routine/Complete Inspection No Violations Noted
1842149 Primary Facility 2009-11-04 Routine/Complete Inspection No Violations Noted
1920978 Primary Facility 2010-10-19 Routine/Complete Inspection No Violations Noted
2025967 Primary Facility 2011-11-17 Routine/Complete Inspection No Violations Noted
2120967 Primary Facility 2012-11-13 Routine/Complete Inspection No Violations Noted
2213316 Primary Facility 2013-10-08 Routine/Complete Inspection No Violations Noted
2312811 Primary Facility 2014-10-07 Routine/Complete Inspection No Violations Noted
2411595 Primary Facility 2015-09-28 Routine/Complete Inspection No Violations Noted
2529059 Primary Facility 2016-10-18 Routine/Complete Inspection No Violations Noted
2641622 Primary Facility 2017-09-25 Routine/Complete Inspection No Violations Noted
2778039 Primary Facility 2018-09-19 Routine/Complete Inspection No Violations Noted Date: 9/18-19/2018

CASING PSI: 1.716

MAX ALLOWABLE PSI: 2,160

VENT: 1. 0 scf/day 2. 0 scf/day 3. 0 scf/day

  • NM= Not Measurable*
  • 0= Not Venting*
  • Scf/day= Standard Cubic Feet Per Day*

VENT: 1. 2.2¿ H2O on 1/8¿ plate 2. ¿ H2O on ¿ plate 3. ¿ H2O on ¿ plate


STATUS: I

  • I= In-Line*
  • P= Plugged*
  • S= Shut in*
  • TP= Temp Plugged*
  • OW= Observation Well*

COMMENTS: New paint 2018

  • TJ/WH= Top Joint/Well Head*
682456 Primary Facility 1988-10-18 Routine/Complete Inspection No Violations Noted
682457 Primary Facility 1989-09-28 Routine/Complete Inspection No Violations Noted
683059 Primary Facility 1990-10-25 Routine/Complete Inspection No Violations Noted
684049 Primary Facility 1991-10-16 Routine/Complete Inspection No Violations Noted
684482 Primary Facility 1992-10-14 Routine/Complete Inspection No Violations Noted
685315 Primary Facility 1993-10-25 Routine/Complete Inspection No Violations Noted
686048 Primary Facility 1994-10-26 Routine/Complete Inspection No Violations Noted
686416 Primary Facility 1995-05-05 Drilling/Alteration No Violations Noted
686445 Primary Facility 1995-04-20 Routine/Complete Inspection No Violations Noted OUT OF SERVICE FOR REPAIRS
686466 Primary Facility 1995-05-10 Drilling/Alteration No Violations Noted
686481 Primary Facility 1995-05-15 Drilling/Alteration No Violations Noted
686485 Primary Facility 1995-05-22 Routine/Complete Inspection No Violations Noted
686490 Primary Facility 1995-05-17 Routine/Complete Inspection No Violations Noted
686540 Primary Facility 1995-06-05 Routine/Complete Inspection No Violations Noted
686679 Primary Facility 1995-08-10 Routine/Complete Inspection No Violations Noted
686695 Primary Facility 1995-09-11 Routine/Complete Inspection No Violations Noted
686973 Primary Facility 1995-10-31 Routine/Complete Inspection No Violations Noted
687094 Primary Facility 1993-12-18 Routine/Complete Inspection Violation(s) Noted
687099 Primary Facility 1995-12-06 Routine/Complete Inspection No Violations Noted
687106 Primary Facility 1996-01-08 Routine/Complete Inspection No Violations Noted
687329 Primary Facility 1996-05-15 Routine/Complete Inspection No Violations Noted
687719 Primary Facility 1996-10-22 Routine/Complete Inspection No Violations Noted
688556 Primary Facility 1997-10-29 Routine/Complete Inspection No Violations Noted
689018 Primary Facility 1998-07-15 Routine/Complete Inspection No Violations Noted
689281 Primary Facility 1998-10-15 Routine/Complete Inspection No Violations Noted
689621 Primary Facility 1999-02-23 Routine/Complete Inspection No Violations Noted
883999 Primary Facility 1999-10-13 Routine/Complete Inspection No Violations Noted
940897 Primary Facility 2000-05-23 Routine/Complete Inspection No Violations Noted
973345 Primary Facility 2000-10-11 Routine/Complete Inspection No Violations Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
687094 106167 12/18/1993 1993-12-18 206REST - Failure to restore site w/in 9 months of completion of drilling or plugging Environmental Health & Safety

For data sources see[6]

References