If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-20349 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.705342,"lon":-77.531664,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Gaines Township | |
Operator Name: TILDEN MARCELLUS LLC | |
Well Pad ID: 148758 | |
Farm/Lease Name: LICK RUN 2H | |
License Status: | |
Spud Date: | |
Permit Date: 2009-08-14 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.705342 | |
Longitude: -77.531664 |
Date | Event |
---|---|
2009-08-14 | New Permit Application |
2010-01-18 | Performed Spud Operation |
2010-04-18 | Drilling Completion |
2010-06-13 | Perforation |
2010-08-10 | DEVIATED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2009 | ULTRA RESOURCES INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2010 | ULTRA RESOURCES INC | 142,945.19 | 133 | 0.00 | 0 | 0.00 | 0 |
2011 | ULTRA RESOURCES INC | 248,986.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | ULTRA RESOURCES INC | 164,527.00 | 364 | 0.00 | 0 | 0.00 | 0 |
2013 | ULTRA RESOURCES INC | 136,006.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 108,132.97 | 251 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 101,593.41 | 182 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 128,923.39 | 326 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 123,524.62 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | SWEPI LP | 101,782.52 | 330 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 106,157.25 | 363 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2010 | ULTRA RESOURCES INC | Produced Fluid | 6,486.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | ULTRA RESOURCES INC | Produced Fluid | 117.40 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | ULTRA RESOURCES INC | Produced Fluid | 29.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | ULTRA RESOURCES INC | Produced Fluid | 112.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2014 | ULTRA RESOURCES INC | Produced Fluid | 169.90 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Produced Fluid | 92.69 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Produced Fluid | 125.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Soil Contaminated by Oil & Gas Related Spills | 0.01 Tons | LANDFILL | 301358 |
2016 | SWEPI LP | Soil Contaminated by Oil | 0.01 Tons | LANDFILL | 301358 |
2017 | SWEPI LP | Produced Fluid | 101.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017 | SWEPI LP | Produced Fluid | 15.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | SWEPI LP | Produced Fluid | 170.50 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 18.03 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWEPI LP | Produced Fluid | 1.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SWEPI LP | Produced Fluid | 110.68 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 33.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2019 | TILDEN MARCELLUS LLC | Produced Fluid | 193.34 Bbl | REUSE (AT WELL PAD) | |
2019 | TILDEN MARCELLUS LLC | Produced Fluid | 33.34 Bbl | STORAGE PENDING DISPOSAL OR REUSE | WMGR123NC036 |
2019 | SWEPI LP | Produced Fluid | 66.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1877372 | Primary Facility | 2010-04-16 | Drilling/Alteration | No Violations Noted | |
2039721 | Primary Facility | 2012-01-26 | Routine/Complete Inspection | No Violations Noted | |
2042175 | Primary Facility | 2012-02-09 | Routine/Complete Inspection | No Violations Noted | |
2048179 | Primary Facility | 2012-03-05 | Routine/Complete Inspection | No Violations Noted | A slope at the rear of the site was slumping and is need of re-grading and stabilization. Several areas, including the fill slopes of the water impoundment are not stabilized. These areas must be covered with either a minimum uniform coverage of mulch and seed, with a density capable of resisting accelerated erosion and sedimentation or an acceptable BMP which minimizes accelerated erosion and sedimentation. Elevated readings for specific conductivity (approximately 2 mS) were measured in puddles on the northeast side of the pad approximately 100 yards from the road. This should be investigated. A follow-up inspection will be conducted to determine if escalated enforcement is necessary. The pipeline and compressor station were not inspected at this time. No violations were cited during this inspection. Violations for 25 PA code §102.22(b) noted during a April 6, 2011 inspection remain outstanding against the 6H well, all other permits associated with this site will be recorded as NOVIO. - MRN |
2085899 | Primary Facility | 2012-07-18 | Routine/Complete Inspection | No Violations Noted | |
2098716 | Primary Facility | 2012-08-24 | Routine/Partial Inspection | No Violations Noted | |
2103630 | Primary Facility | 2012-09-26 | Routine/Partial Inspection | No Violations Noted | |
2108993 | Primary Facility | 2012-10-15 | Routine/Partial Inspection | No Violations Noted | A site visit was conducted on October 15, 2012 at the Lick Run Pad in Gaines Township, Tioga Co. The date of the last inspection conducted by AMEC is unknown. 25 PA Code §102.4(b)(5)(x) requires a written report documenting each inspection, this should include the date the inspection was conducted. The site is currently being restored. The area has been restored to near original contours and the water impoundment is no longer present. The E&S controls were installed and functioning. The site needs to be stabilized as soon as possible to reduce the risk of accelerated erosion. The Pipeline and Compressor Station were not part of this inspection. The photos are attached to the ESX10-117-0013 inpsection report. No violations were cited during this inspection. - MRN |
2323110 | Primary Facility | 2014-11-05 | Routine/Partial Inspection | No Violations Noted | |
2567580 | Primary Facility | 2017-03-03 | Routine/Complete Inspection | No Violations Noted | The DEP inspected the SWEPI LP lick run 803 well pad located in Gaines Township Tioga County on March 3, 2017. The weather was 30 D, cloudy with snow squalls. A light dusting of snow was observed on the pad surface. The site appeared stabilized. No E&S issues were observed. No violations were noted during this inspection. Please contact me with any questions. |
2628978 | Primary Facility | 2017-07-27 | Site Restoration | No Violations Noted | Site has been restored. 1H - 6H wells are in production. Site is permanently stabilized, post-construction stormwater BMPs are installed and temporary E&S controls removed. Well Site Restoration Report received on 7/25/17 and acknowledged on 7/27/17. Notice of Termination received on 7/24/17 and approved on 8/4/17. TLT |
2714789 | Primary Facility | 2018-04-02 | Site Restoration | No Violations Noted | The Department of Environmental Protection inspected the SWEPI LP – Lick Run 803 well site on April 2, 2018 @ 1245 hours. The site ESCGP included the well pad, compressor station and PL-106 (connecting the well pad to the compressor station). The weather was 42 degrees and sunny. There was no activity onsite during my inspection.
The 1H – 6H wells are drilled and in production. The well pad has been restored and PCSM BMPs have been installed. The NOT and WSRR were approved on 7/27/2017. The pipeline and well pad appeared to be stabilized with a permanent vegetative cover during the inspection. Vegetated portions of the pad appeared to be saturated with water and have poor drainage. No violations are noted at this time. I departed the site at 1330 hours. |
For data sources see[7]