{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.797322,"lon":-77.244408,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Charleston Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 149493 | |
Farm/Lease Name: VANDERGRIFT 290 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-04-30 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.797322 | |
Longitude: -77.244408 |
Date | Event |
---|---|
2010-04-30 | New Permit Application |
2010-05-15 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-04-15 | 2012-04-15 | 5,916 | 3,731,868 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | FE-4 | Univar | Iron Control/Reducer | Water | 7732-18-5 | 50.00 | 0.00058000 | |
Citric acid | 77-92-9 | 50.00 | 0.00058000 | |||||
FR-900 | Nalco | Scale Inhibitor | not classified as hazardous | 100.00 | 0.07 | |||
Hydrochloric Acid | Reagent Chemical & Research | Water | 85.00 | 0.32 | ||||
Hydrochloric acid | 7647-01-0 | 15.00 | 0.05 | |||||
Sand | Badger Mining Co. | Proppant | Quartz | 14808-60-7 | 99.90 | 6.51 | ||
I-22 | Nalco | Acid Corrosion Inhibitor | Oxyalkylated Fatty Acid | 30.00 | 0.00011000 | |||
Benzyl chloride | 100-44-7 | 1.00 | 0.00 | |||||
Haloalkyl heteropolycycle salt | 30.00 | 0.00011000 | ||||||
Isopropanol | 67-63-0 | 5.00 | 0.00002000 | |||||
Quaternary ammonium compounds | 5.00 | 0.00002000 | ||||||
Aromatic aldehyde | 30.00 | 0.00011000 | ||||||
Formic acid | 64-18-6 | 60.00 | 0.00023000 | |||||
Methanol | 67-56-1 | 5.00 | 0.00002000 | |||||
Organic sulfur compounds | 5.00 | 0.00002000 | ||||||
Water | Shell | 100.00 | 93.33 | |||||
MSI-7 | National Petrochemical | Scale Inhibitor | Hydorgen Chloride | 0.00924000 | ||||
Plex 907 | Chemplex | Gelling Agent/Thickener | vegetable gums | 100.00 | 0.02 | |||
Plexgel Breaker | Chemplex | Enzyme Breaker | not classified as hazardous | 100.00 | 0.00024000 | |||
PetroFlow | Bio-Cide International | Biocide | Sodium hydroxide | 1310-73-2 | 1.00 | 0.04 | ||
Sodium carbonate | 497-19-8 | 2.00 | 0.09 | |||||
Water | 7732-18-5 | 87.65 | 0.04 | |||||
Sodium chlorite | 7758-19-2 | 8.35 | 0.00386000 | |||||
Sodium chloride | 7647-14-5 | 1.00 | 0.04 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EAST RESOURCES MGMT LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SWEPI LP | 687,281.78 | 226 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 694,118.32 | 359 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 518,535.52 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 413,280.74 | 358 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 351,966.95 | 360 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 304,169.07 | 364 | 0.00 | 0 | 0.00 | 0 |
2018 | SWEPI LP | 271,959.89 | 360 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 236,593.19 | 342 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SWEPI LP | Produced Fluid | 50.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | SWEPI LP | Produced Fluid | 1,589.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SWEPI LP | Drilling Fluid Waste | 13.75 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Fracing Fluid Waste | 3,110.17 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SWEPI LP | Fracing Fluid Waste | 887.14 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | SWEPI LP | Fracing Fluid Waste | 467.04 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Spent Lubricant | 16.07 Bbl | CENT WASTE TRT FAC NPDES | PAD987266749 |
2012 | SWEPI LP | Spent Lubricant | 16.07 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PAD987266749 |
2013 | SWEPI LP | Produced Fluid | 15.46 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2013 | SWEPI LP | Produced Fluid | 3,243.62 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SWEPI LP | Produced Fluid | 126.72 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | SWEPI LP | Fracing Fluid Waste | 33.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | SWEPI LP | Produced Fluid | 252.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2013 | SWEPI LP | Fracing Fluid Waste | 32.54 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 979.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 300.06 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014 | SWEPI LP | Produced Fluid | 49.78 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Produced Fluid | 25.64 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SWEPI LP | Produced Fluid | 648.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWEPI LP | Produced Fluid | 90.97 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Produced Fluid | 621.68 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Produced Fluid | 125.03 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWEPI LP | Produced Fluid | 747.84 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWEPI LP | Produced Fluid | 99.99 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | SWEPI LP | Produced Fluid | 757.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWEPI LP | Produced Fluid | 210.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2018 | SWEPI LP | Produced Fluid | 25.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2018 | SWEPI LP | Produced Fluid | 799.99 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 151.09 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWEPI LP | Produced Fluid | 26.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWEPI LP | Produced Fluid | 83.81 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | SWEPI LP | Produced Fluid | 20.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2019 | SWEPI LP | Produced Fluid | 515.00 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1888781 | Primary Facility | 2010-06-02 | Compliance Evaluation | Violation(s) Noted | CEI inspection to investigate a diesel spill on 6-2-10. |
1915033 | Primary Facility | 2010-09-22 | Compliance Evaluation | No Violations Noted | CEI insp to close out violations from 6-2-10 insp (diesel spill) ID#1888781. TLT |
1956176 | Primary Facility | 2011-03-08 | Complaint Inspection | No Violations Noted | complaint #277642 |
2269031 | Primary Facility | 2014-04-28 | Routine/Complete Inspection | No Violations Noted | |
2273224 | Primary Facility | 2014-05-21 | Routine/Complete Inspection | No Violations Noted | Outstanding violations remain against the 2H. TLT |
2338942 | Primary Facility | 2015-01-23 | Site Restoration | No Violations Noted | ESCGP Notice of Termination (NOT) and Well Site Restoration Reports received 12/24/14. Recommend denial of NOT. Temporary E&S controls are still present and site is snow covered and permanent stabilization cannot be verified. Well Site Restoration Reports have been acknowledged. TLT |
2433996 | Primary Facility | 2015-12-15 | Site Restoration | No Violations Noted | Restoration inspection. Notice of Termination received 12/14/15. Interim restoration of pad completed. Two rock-lined diversion channels remain that are shown as having been removed on the restoration drawing. Also, a recently reclaimed channel is stabilized with erosion control blanket but not yet vegetated. Recommend denial of the NOT based on these observations. TLT |
2531586 | Primary Facility | 2016-10-20 | Site Restoration | No Violations Noted | Restoration inspection. The Notice of Termination was received on 10/19/16. The site is permanently stabilized, E&S controls have been removed and post-construction stormwater management controls are in place. Recommend approval of the Notice of Termination. TLT |
2710421 | Primary Facility | 2018-03-26 | Routine/Partial Inspection | No Violations Noted | I got an electrical conductivity reading of 0.51 mS/cm from a puddle near the production tanks with an Oakton PCSTestr 35. SWEPI inspection log is in a mailbox near the production tanks; the last inspection is listed on March 24, 2018. Air temp 47F. JLP |
2829405 | Primary Facility | 2019-01-18 | Routine/Complete Inspection | No Violations Noted | The DEP conducted a routine inspection of SWEPI's Vandergrift 290 Well Pad in Charleston Twp, Tioga County on 1/18/2019 at 1240 hours. The weather was 32 degrees, cloudy and 1/4 inch of snow covered the pad surface.
This pad has been reduced in size and the resized portions are well vegetated. There are currently 6 wells (1H-6H) that appear to be capable of production with two production tanks. The site is well vegetated and remains stabilized. No erosional issues were observed today. No violations or issues noted today, I departed the site at 1300 hours. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1888781 | 588624 | 06/02/2010 | 2010-06-02 | 691.1 - Clean Streams Law-General. Used only when a specific CLS code cannot be used | Administrative | CSL 402. Diesel spill of unknown quantity migraged off pad with potential to impact down gradient pond and stream. TLT |
1888781 | 588625 | 06/02/2010 | 2010-06-02 | 601.101 - O&G Act 223-General. Used only when a specific O&G Act code cannot be used | Administrative | SWMA 301. Unpermitted discharge of diesel fuel on to the ground. TLT |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
588624 | 258751 | NOV - Notice of Violation | Comply/Closed | 2010-10-01 | |||
588625 | 258751 | NOV - Notice of Violation | Comply/Closed | 2010-10-01 |