{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.679247,"lon":-77.387753,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Delmar Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 148301 | |
Farm/Lease Name: ERICKSON 448 4H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-09-08 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.679247 | |
Longitude: -77.387753 |
Date | Event |
---|---|
2010-09-08 | New Permit Application |
2010-09-25 | Performed Spud Operation |
2011-02-12 | Drilling Completion |
2012-03-24 | Perforation |
2012-12-11 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-04-01 | 2012-04-01 | 5,555 | 3,095,778 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | BE-9 Biocide | Biocide | Tri-n-butyl tetradecyl phosphonium chloride | 81741-28-8 | 10.00 | 0.00387000 | ||
LP-65 | Scale Inhibitor | Ammonium chloride | 12125-02-9 | 10.00 | 0.00245000 | |||
HAI-OS ACID INHIBITOR | Corrosion Inhibitor | Methanol | 67-56-1 | 60.00 | 0.00018000 | |||
Propargyl alcohol | 107-19-7 | 10.00 | 0.00003000 | |||||
LGC-36 UC | Gelling Agent | Guar gum | 9000-30-0 | 60.00 | 0.00074000 | |||
Naphtha, petroleum, hydrotreated heavy | 64742-48-9 | 60.00 | 0.00074000 | |||||
Fresh Water/Produced Water | Shell | Carrier Fluid | Hydrochloric acid | 7647-01-0 | 100.00 | 85.13 | ||
20 baume HCl | Breakdown | Hydrochloric acid | 7647-01-0 | 100.00 | 0.17 | |||
FE-1A Acidizing Agent | Iron Control | Acetic acid | 64-19-7 | 60.00 | 0.00108000 | |||
Acetic anhydride | 108-24-7 | 100.00 | 0.00180000 | |||||
Gasperm 1000 | Surfactant | Isopropanol | 67-63-0 | 30.00 | 0.03 | |||
Terpenes and Terpenoids, sweet orange-oil | 68647-72-3 | 30.00 | 0.03 | |||||
FR-66 Friction Reducer | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | |||
GBW-30 BREAKER | Breaker | Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00 | |||
SP Breaker | Breaker | Sodium persulfate | 7775-27-1 | 100.00 | 0.00003000 | |||
Natural Sand | Proppant | Quartz | 14808-60-7 | 100.00 | 14.46 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | EAST RESOURCES MGMT LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SWEPI LP | 416,387.21 | 220 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 395,897.99 | 356 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 285,525.94 | 348 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 241,382.13 | 350 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 200,181.49 | 336 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 169,122.17 | 329 | 0.00 | 0 | 0.00 | 0 |
2018 | SWEPI LP | 155,227.73 | 335 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 124,577.31 | 248 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SWEPI LP | Produced Fluid | 4,449.99 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2012 | SWEPI LP | Produced Fluid | 325.40 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SWEPI LP | Fracing Fluid Waste | 338.54 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Drilling Fluid Waste | 27.50 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Produced Fluid | 372.98 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Fracing Fluid Waste | 7,308.89 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SWEPI LP | Produced Fluid | 33.33 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2012 | SWEPI LP | Fracing Fluid Waste | 309.89 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2012 | SWEPI LP | Fracing Fluid Waste | 866.19 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2013 | SWEPI LP | Produced Fluid | 29.89 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW018 |
2013 | SWEPI LP | Produced Fluid | 8,489.14 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SWEPI LP | Produced Fluid | 692.18 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | SWEPI LP | Fracing Fluid Waste | 16.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR119 |
2013 | SWEPI LP | Fracing Fluid Waste | 18.65 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 2,280.55 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 66.68 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2014 | SWEPI LP | Produced Fluid | 206.77 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Produced Fluid | 33.34 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC011 |
2015 | SWEPI LP | Produced Fluid | 51.82 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SWEPI LP | Produced Fluid | 1,204.21 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWEPI LP | Produced Fluid | 1,617.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Produced Fluid | 150.03 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWEPI LP | Produced Fluid | 1,794.66 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWEPI LP | Produced Fluid | 15.45 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | SWEPI LP | Synthetic Liner Materials | 0.56 Tons | LANDFILL | 301358 |
2017 | SWEPI LP | Produced Fluid | 99.99 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2017 | SWEPI LP | Produced Fluid | 283.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017 | SWEPI LP | Produced Fluid | 956.97 Bbl | REUSE (AT WELL PAD) | |
2017 | SWEPI LP | Waste Water Treatment Sludge | 1.79 Tons | STORAGE PENDING DISPOSAL OR REUSE | PA-0678 |
2018 | SWEPI LP | Soil Contaminated by Oil | 0.01 Tons | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2018 | SWEPI LP | Produced Fluid | 83.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2018 | SWEPI LP | Produced Fluid | 828.65 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Soil Contaminated by Oil & Gas Related Spills | 0.01 Tons | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2018 | SWEPI LP | Produced Fluid | 271.98 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWEPI LP | Produced Fluid | 17.48 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWEPI LP | Produced Fluid | 83.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | SWEPI LP | Produced Fluid | 82.49 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | SWEPI LP | Produced Fluid | 33.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2019 | SWEPI LP | Produced Fluid | 251.17 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1957003 | Primary Facility | 2011-03-11 | Drilling/Alteration | No Violations Noted | |
2019080 | Primary Facility | 2011-11-09 | Routine/Complete Inspection | No Violations Noted | |
2116190 | Primary Facility | 2012-11-09 | Routine/Partial Inspection | No Violations Noted | |
2126290 | Primary Facility | 2012-12-28 | Routine/Partial Inspection | No Violations Noted | |
2139510 | Primary Facility | 2013-02-11 | Routine/Partial Inspection | No Violations Noted | |
2414436 | Primary Facility | 2015-10-08 | Routine/Partial Inspection | No Violations Noted | Routine inspection. Pad surface is stable. Areas surrounding the pad are permanently stabilized and E&S controls remain in place. Site has not been restored, however, the 1X well permit is valid and was issued on 1/13/15. No issues noted. TLT |
2558676 | Primary Facility | 2017-02-02 | Routine/Partial Inspection | No Violations Noted | Routine partial inspection. Site was idle and snow covered. The 1H - 6H wells have been drilled and are in production. A temporary containment structure was staged along the west side of the pad; the containment held a 500 barrel tank and sealed waste container. The site has not been restored. A restoration extension request was received from SWEPI on 2/16/16. No violations were cited during the inspection. TLT |
2590809 | Primary Facility | 2017-05-04 | Routine/Complete Inspection | No Violations Noted | On 5/4/17 at 1230 hrs I conducted a routine inspection at the Erickson 448 well site. It was raining and 48 degrees F. A contractor arrived at the site during my inspection. The contractor removed a pile of fill staged on the pad and loaded up a piece of equipment.
The 1H - 6H wells have been drilled, tagged and are in production. The 500 barrel (bbl) tank and sealed container noted during the last inspection on 2/2/17 remain staged in temporary containment along the west side of the pad. Field conductivity of the temporary containment water was 743 micro Siemens/cm. The production equipment has built-in containment, which appeared to be in good condition. No staining or evidence of spills was noted; conductivity of standing water on the pad surface was 577 micro Siemens/cm. Interim restoration of the site is ongoing. The E&S inspection log documents that restoration work began on 4/23/17. Site restoration included removal of the sediment traps, perimeter rock-lined channels and the topsoil stockpile east |
2619128 | Primary Facility | 2017-07-24 | Site Restoration | No Violations Noted | On 7/24/17 at 1437 hrs I conducted an inspection of the Erickson 448 well site. SWEPI representative, Chris Citrino, was present during the inspection. It was mostly sunny and 79 degrees F.
I observed the site and reviewed the erosion and sedimentation (E&S) routine inspection log, the Notice of Termination (NOT) and the Well Site Restoration Report (WSRR). The well site has been restored and post-construction stormwater management (PCSM) BMPs have been installed. Temporary E&S controls have been removed and the project is permanently stabilized as per 25 Pa Code Section 102.22(a)(2). The last routine E&S inspection was conducted on 7/23/17. A 500 barrel (bbl) tank and a sealed vac box were staged in secondary containment. Mr. Citrino stated that the sealed vac box is scheduled for disposal and the 500 bbl tank provides additional storage capacity for production fluids. Standing water was observed in the secondary containment; the specific conductance field measurement was 660 micro Siemens/cm. Puddles o |
2741011 | Primary Facility | 2018-06-13 | Routine/Complete Inspection | No Violations Noted | A inspection was conducted at the Erickson 448 well pad. The weather during the inspection was 72°F and cloudy. This site is interim restored with the earth disturbance permit being terminated and well site restoration reports acknowledged on July 26, 2017. There are six gas was on site capable of production. Post construction Stormwater management BMPs are installed. The site is permanently stabilized as required under Chapter 102.22. No erosion issues were noted and no evidence of spills observed during this inspection. No violations were cited during this inspection |