If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21119 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.687033,"lon":-77.127603,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Bloss Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 148207 | |
Farm/Lease Name: DCNR 595 38H 50299 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-12-27 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.687033 | |
Longitude: -77.127603 |
Date | Event |
---|---|
2010-12-27 | New Permit Application |
2011-02-07 | Performed Spud Operation |
2011-10-27 | New Permit Application |
2011-11-16 | Drilling Completion |
2011-12-20 | Perforation |
2012-12-12 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-12-20 | 2011-12-20 | 8,036 | 6,596,982 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | BioRid 20L | Tetra | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00291000 | |
Sodium bromide | 7647-15-6 | 15.00 | 0.00218000 | |||||
15 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00948000 | ||
ScaleHib 100 | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 60.00 | 0.00626000 | ||
Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
Unihib G | Universal Well Services | Corrosion Inhibitor | Resin Based Nonionic Inhibitor | 35.00 | 0.00014000 | |||
Diethylene glycol monobutyl ether | 112-34-5 | 50.00 | 0.00021000 | |||||
Ethoxylated Alcohol | 35.00 | 0.00014000 | ||||||
Proppant 40/70 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 6.39 | ||
Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.06 | ||
7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.06 | ||
Proppant 30/50 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 6.09 | ||
Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00046000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SENECA RESOURCES CO LLC | 1,331,570.00 | 301 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 1,046,514.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 801,827.50 | 352 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 438,418.55 | 168 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 699,274.61 | 362 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 519,585.36 | 358 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 433,489.73 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 394,133.79 | 360 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 2,135.78 Tons | LANDFILL | 301358 |
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 377.86 Tons | LANDFILL | |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 11,329.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 743.26 Tons | LANDFILL | 301358 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 224.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | 3192 |
2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 8,088.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Drill Cuttings | 11.95 Tons | LANDFILL | 301358 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 4,981.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 43.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 402.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 1,031.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 37.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 41.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 22.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20114 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 210.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 95.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 18.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 289.17 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 187.92 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 346.17 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 263.34 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 27.50 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 351.67 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 38.33 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 94.17 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 21.67 Bbl | STORAGE PENDING DISPOSAL OR REUSE | WMGR123NC038 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 167.51 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2027353 | Primary Facility | 2011-12-15 | Routine/Complete Inspection | No Violations Noted | |
2071328 | Primary Facility | 2012-05-25 | Follow-up Inspection | No Violations Noted | liquid in sump 2.2 mS/cm |
2078026 | Primary Facility | 2012-06-20 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | digging out contaminated soil on pad |
2164851 | Primary Facility | 2013-04-30 | Routine/Complete Inspection | No Violations Noted | |
2364687 | Primary Facility | 2015-04-27 | Routine/Partial Inspection | No Violations Noted | Overdue for restoration. 6 Marcellus gas wells in production |
2513078 | Primary Facility | 2016-08-22 | Routine/Complete Inspection | No Violations Noted | |
2518335 | Primary Facility | 2016-09-12 | Routine/Complete Inspection | No Violations Noted | -Inspection of Seneca Resources Corporation’s DCNR 595 Pad F in Bloss Twp. Tioga County conducted September 12, 2016 at 1:10 pm. There were (2) plugged wells and (6) active wells on the pad at the time of inspection.
-The 58H (Plugged 7-12-16) had casing cut below ground level, cellar filled with gravel, and had an 8’ high 3” candy cane vent. I detected no gas with an Altair 5x gas meter. The other plugged well was the 55H (Plugged 7-12-16). It appeared this one had casing cut in the cellar below ground level, filled with gravel, no above-ground monument. No gas detected in ambient air near the cellar. -The remaining (6) wells all had production trees in place (Active). I did a visual inspection of the wells. All the wells had digital pressure gauges on the tree top and off the production casing wing valve with not much pressure differential; either no tubing or pressure regulating tool in the tubing string. All wells had (1020-1094)PSI with the exception of the 38H only had 391PSI surface pressure. All th |
2614058 | Primary Facility | 2017-07-10 | Routine/Complete Inspection | Violation(s) Noted | Six Wells in production phase (36H, 37H, 38H, 39H, 40H and 41H) and Two Wells plugged (55H and 56H). Six dehydration units. No leaks detected from production units. The well pad surface remains at the original build size of 300 x 600 feet. No active drilling permits for the DCNR Pad F at the time of inspection. Violations noted for failure to restore well site. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2614058 | 791125 | 2017-07-10 | 2018-02-09 | OGA3216(A) | Environmental Health & Safety | My inspection revealed that you failed to restore the DCNR 595 Pad F site after the
completion of drilling. This is a violation of the Oil and Gas Act, 58 P.S. section 3216(a) which provides: A) General rule. Each oil and gas well owner or operator shall restore the land service within the area dist |
2614058 | 791126 | 2017-07-10 | 2018-02-09 | 78a65(a)1 | Environmental Health & Safety | Failure to minimize and restore the well site. This site is not in compliance with the
restoration schedule submitted to the DEP by Seneca. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
791125 | 356110 | NOV - Notice of Violation | 2018-02-09 | ||||
791126 | 356110 | NOV - Notice of Violation | 2018-02-09 |
For data sources see[8]