X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-117-21119

Well Details

Well ID: 37-117-21119
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Bloss Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148207
Farm/Lease Name: DCNR 595 38H 50299
License Status:
Spud Date:
Permit Date: 2010-12-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.687033
Longitude: -77.127603

For data sources see[1][2][3]

Well History

Date Event
2010-12-27 New Permit Application
2011-02-07 Performed Spud Operation
2011-10-27 New Permit Application
2011-11-16 Drilling Completion
2011-12-20 Perforation
2012-12-12 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-12-20 2011-12-20 8,036 6,596,982

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BioRid 20L Tetra Biocide 2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00291000
Sodium bromide 7647-15-6 15.00 0.00218000
15 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 15.00 0.00948000
ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene glycol 107-21-1 60.00 0.00626000
Unislik ST 50 Universal Well Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Unihib G Universal Well Services Corrosion Inhibitor Resin Based Nonionic Inhibitor 35.00 0.00014000
Diethylene glycol monobutyl ether 112-34-5 50.00 0.00021000
Ethoxylated Alcohol 35.00 0.00014000
Proppant 40/70 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 6.39
Proppant 80/100 Oklahoma Universal Well Services Proppant Quartz 14808-60-7 100.00 0.06
7.5 HydroChloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 7.50 0.06
Proppant 30/50 Ottawa Universal Well Services Proppant Quartz 14808-60-7 100.00 6.09
Iron Stabilizer II Universal Well Services Corrosion Inhibitor Ethylene glycol 107-21-1 30.00 0.00046000

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 1,331,570.00 301 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 1,046,514.00 365 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 801,827.50 352 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 438,418.55 168 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 699,274.61 362 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 519,585.36 358 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 433,489.73 365 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 394,133.79 360 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SENECA RESOURCES CO LLC Drill Cuttings 2,135.78 Tons LANDFILL 301358
2011 SENECA RESOURCES CO LLC Drill Cuttings 377.86 Tons LANDFILL
2012 SENECA RESOURCES CO LLC Produced Fluid 11,329.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Fracturing Fluid Waste 743.26 Tons LANDFILL 301358
2012 SENECA RESOURCES CO LLC Produced Fluid 224.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE 3192
2012 SENECA RESOURCES CO LLC Fracing Fluid Waste 8,088.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Drill Cuttings 11.95 Tons LANDFILL 301358
2013 SENECA RESOURCES CO LLC Produced Fluid 4,981.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SENECA RESOURCES CO LLC Produced Fluid 43.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC012
2013 SENECA RESOURCES CO LLC Produced Fluid 402.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 1,031.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 SENECA RESOURCES CO LLC Produced Fluid 37.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2015 SENECA RESOURCES CO LLC Produced Fluid 41.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid 22.00 Bbl INJECTION DISPOSAL WELL 34-133-20114
2015 SENECA RESOURCES CO LLC Produced Fluid 210.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 95.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2016 SENECA RESOURCES CO LLC Produced Fluid 18.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 289.17 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 187.92 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 346.17 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 263.34 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 27.50 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Produced Fluid 351.67 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 38.33 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 94.17 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 21.67 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC038
2019 SENECA RESOURCES CO LLC Produced Fluid 167.51 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2027353 Primary Facility 2011-12-15 Routine/Complete Inspection No Violations Noted
2071328 Primary Facility 2012-05-25 Follow-up Inspection No Violations Noted liquid in sump 2.2 mS/cm
2078026 Primary Facility 2012-06-20 Follow-up Inspection Outstanding Violations - No Viols Req'd digging out contaminated soil on pad
2164851 Primary Facility 2013-04-30 Routine/Complete Inspection No Violations Noted
2364687 Primary Facility 2015-04-27 Routine/Partial Inspection No Violations Noted Overdue for restoration. 6 Marcellus gas wells in production
2513078 Primary Facility 2016-08-22 Routine/Complete Inspection No Violations Noted
2518335 Primary Facility 2016-09-12 Routine/Complete Inspection No Violations Noted -Inspection of Seneca Resources Corporation’s DCNR 595 Pad F in Bloss Twp. Tioga County conducted September 12, 2016 at 1:10 pm. There were (2) plugged wells and (6) active wells on the pad at the time of inspection.

-The 58H (Plugged 7-12-16) had casing cut below ground level, cellar filled with gravel, and had an 8’ high 3” candy cane vent. I detected no gas with an Altair 5x gas meter. The other plugged well was the 55H (Plugged 7-12-16). It appeared this one had casing cut in the cellar below ground level, filled with gravel, no above-ground monument. No gas detected in ambient air near the cellar. -The remaining (6) wells all had production trees in place (Active). I did a visual inspection of the wells. All the wells had digital pressure gauges on the tree top and off the production casing wing valve with not much pressure differential; either no tubing or pressure regulating tool in the tubing string. All wells had (1020-1094)PSI with the exception of the 38H only had 391PSI surface pressure. All th

2614058 Primary Facility 2017-07-10 Routine/Complete Inspection Violation(s) Noted Six Wells in production phase (36H, 37H, 38H, 39H, 40H and 41H) and Two Wells plugged (55H and 56H). Six dehydration units. No leaks detected from production units. The well pad surface remains at the original build size of 300 x 600 feet. No active drilling permits for the DCNR Pad F at the time of inspection. Violations noted for failure to restore well site.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2614058 791125 2017-07-10 2018-02-09 OGA3216(A) Environmental Health & Safety My inspection revealed that you failed to restore the DCNR 595 Pad F site after the

completion of drilling. This is a violation of the Oil and Gas Act, 58 P.S. section 3216(a) which provides: A) General rule. Each oil and gas well owner or operator shall restore the land service within the area dist

2614058 791126 2017-07-10 2018-02-09 78a65(a)1 Environmental Health & Safety Failure to minimize and restore the well site. This site is not in compliance with the

restoration schedule submitted to the DEP by Seneca.

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
791125 356110 NOV - Notice of Violation 2018-02-09
791126 356110 NOV - Notice of Violation 2018-02-09

For data sources see[8]

References