37-117-21124

Well Details

Well ID: 37-117-21124
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Bloss Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 148207
Farm/Lease Name: DCNR 595 56H 50452
License Status: PLUGGED & ABANDONED
Spud Date:
Permit Date: 2010-12-27
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.687081
Longitude: -77.127264

For data sources see[1][2][3]

Well History

Date Event
2010-12-27 New Permit Application
2013-07-12 Drilling Completion
2015-03-26 FULLY PLUGGED
2015-03-26 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2011 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2071338 Primary Facility 2012-05-25 Follow-up Inspection No Violations Noted liquid in sump 2.2 mS/cm
2078031 Primary Facility 2012-06-20 Follow-up Inspection Outstanding Violations - No Viols Req'd digging out contaminated soil on pad
2164846 Primary Facility 2013-04-30 Routine/Complete Inspection No Violations Noted
2213666 Primary Facility 2013-10-17 Plugging(Includes Plugged/Mined Through) No Violations Noted
2364695 Primary Facility 2015-04-27 Routine/Partial Inspection No Violations Noted Overdue for restoration. 6 Marcellus gas wells in production
2513071 Primary Facility 2016-08-22 Routine/Complete Inspection No Violations Noted
2518340 Primary Facility 2016-09-12 Routine/Complete Inspection No Violations Noted -Inspection of Seneca Resources Corporation’s DCNR 595 Pad F in Bloss Twp. Tioga County conducted September 12, 2016 at 1:10 pm. There were (2) plugged wells and (6) active wells on the pad at the time of inspection.

-The 58H (Plugged 7-12-16) had casing cut below ground level, cellar filled with gravel, and had an 8’ high 3” candy cane vent. I detected no gas with an Altair 5x gas meter. The other plugged well was the 55H (Plugged 7-12-16). It appeared this one had casing cut in the cellar below ground level, filled with gravel, no above-ground monument. No gas detected in ambient air near the cellar. -The remaining (6) wells all had production trees in place (Active). I did a visual inspection of the wells. All the wells had digital pressure gauges on the tree top and off the production casing wing valve with not much pressure differential; either no tubing or pressure regulating tool in the tubing string. All wells had (1020-1094)PSI with the exception of the 38H only had 391PSI surface pressure. All th

For data sources see[6]