Well ID: 37-117-21162 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.739281,"lon":-77.104496,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Covington Township | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 149489 | |
Farm/Lease Name: VALLDES 1H R 50496 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-01-26 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.739281 | |
Longitude: -77.104496 |
Date | Event |
---|---|
2011-01-26 | New Permit Application |
2011-03-08 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-06-18 | 2011-06-18 | 6,106 | 4,028,430 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Unigel CMHPG Guar Product | Universal Well Services | Gelling Agent | No Hazardous Components | 0.00 | |||
NE-90 | Universal Well Services | Non-Emulsifier | Isopropanol | 67-63-0 | 10.00 | 0.00002000 | ||
Alcohols, C7-9-iso-, C8-rich, ethoxylated | 78330-19-5 | 5.00 | 0.00001000 | |||||
Polyethylene glycol | 25322-68-3 | 5.00 | 0.00001000 | |||||
Solvent naphtha, petroleum, heavy arom. | 64742-94-5 | 5.00 | 0.00001000 | |||||
Alcohols, C9-11-iso-, C10-rich, ethoxylated | 78330-20-8 | 5.00 | 0.00001000 | |||||
2-Ethylhexanol | 104-76-7 | 10.00 | 0.00002000 | |||||
Naphthalene | 91-20-3 | 1.00 | 0.00 | |||||
Methanol | 67-56-1 | 60.00 | 0.00012000 | |||||
Iron Sta IIC | Universal Well Services | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00024000 | ||
32 Hydrochloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 32.00 | 0.03 | ||
Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | ||
BioRid 20L | Tetra | Biocide | Sodium bromide | 7647-15-6 | 15.00 | 0.00187000 | ||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00249000 | |||||
Sand (Proppant) | Universal Well Services | Proppant | Quartz | 14808-60-7 | 99.90 | 12.23 | ||
LEB-10X | Universal Well Services | Enzyme Breaker | Ethylene glycol | 107-21-1 | 60.00 | 0.00001000 | ||
Unihib A | Universal Well Services | Corrosion Inhibitor | 1,2,4-Trimethylbenzene | 95-63-6 | 5.00 | 0.00001000 | ||
Solvent naphtha, petroleum, light arom | 64742-95-6 | 10.00 | 0.00002000 | |||||
C10-C16 ethoxylated alcohol | 68002-97-1 | 30.00 | 0.00006000 | |||||
Naphtha, petroleum, heavy catalytic reformed | 64741-68-0 | 10.00 | 0.00002000 | |||||
Xylenes | 1330-20-7 | 1.00 | 0.00 | |||||
Diethylbenzene | 25340-17-4 | 1.00 | 0.00 | |||||
Methanol | 67-56-1 | 30.00 | 0.00006000 | |||||
Kerosine, petroleum, hydrodesulfurized | 64742-81-0 | 5.00 | 0.00001000 | |||||
Isomeric Aromatic Ammonium Salt | 10.00 | 0.00002000 | ||||||
Cumene | 98-82-8 | 1.00 | 0.00 | |||||
Isopropanol | 67-63-0 | 5.00 | 0.00001000 | |||||
Formalin | 50-00-0 | 1.00 | 0.00 | |||||
Navy fuels JP-5 | 8008-20-6 | 5.00 | 0.00001000 | |||||
Naphthalene | 91-20-3 | 1.00 | 0.00 | |||||
1,3,5-Trimethylbenzene | 108-67-8 | 1.00 | 0.00 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 5.00 | 0.00001000 | |||||
2-substituted Aromatic Amine Salt | 5.00 | 0.00001000 | ||||||
Water | Universal Well Services | Carrier/Base Fluid | 87.63 | |||||
ScaleHib 100 | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 60.00 | 0.01 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SENECA RESOURCES CO LLC | 244,434.00 | 149 | 0.00 | 0 | 0.00 | 0 |
2012 | SENECA RESOURCES CO LLC | 341,915.00 | 328 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 244,405.00 | 323 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 205,502.80 | 320 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 111,252.49 | 233 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 31,278.12 | 50 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 45,890.26 | 68 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 149,121.15 | 300 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 142,376.12 | 356 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 4.22 Tons | LANDFILL | 100361 |
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 149.97 Tons | LANDFILL | 8-4630-00010/00 |
2011 | SENECA RESOURCES CO LLC | Produced Fluid | 20,328.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 790.60 Tons | LANDFILL | 100955 |
2011 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 3,107.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 8,016.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 19.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 2,514.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 411.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 896.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 16.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 2,614.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 213.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 38.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW005 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 987.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 52.53 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 115.20 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 205.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 754.51 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 696.27 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 48.75 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 119.38 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 307.52 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 15.00 Bbl | STORAGE PENDING DISPOSAL OR REUSE | WMGR123NC038 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 43.13 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC003 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 443.66 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1958349 | Primary Facility | 2011-03-18 | Drilling/Alteration | No Violations Noted | |
1966383 | Primary Facility | 2011-04-18 | Drilling/Alteration | Violation(s) Noted | |
1990058 | Primary Facility | 2011-06-14 | Compliance Evaluation | No Violations Noted | 1H 2H cellars bubbling. Flowback pit onsite |
1999765 | Primary Facility | 2011-07-27 | Routine/Complete Inspection | No Violations Noted | |
1999767 | Primary Facility | 2011-08-03 | Routine/Complete Inspection | No Violations Noted | |
2136328 | Primary Facility | 2013-02-04 | Routine/Complete Inspection | No Violations Noted | |
2136354 | Primary Facility | 2013-02-04 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | |
2144609 | Primary Facility | 2013-03-01 | Routine/Complete Inspection | No Violations Noted | |
2204355 | Primary Facility | 2013-09-09 | Routine/Complete Inspection | No Violations Noted | |
2248608 | Primary Facility | 2014-02-24 | Routine/Complete Inspection | No Violations Noted | |
2280286 | Primary Facility | 2014-06-02 | Routine/Complete Inspection | No Violations Noted | |
2280379 | Primary Facility | 2014-06-06 | Routine/Complete Inspection | Pending | Gas detected outside surface casing following PBT. VIOLs pending analytical results |
2298598 | Primary Facility | 2014-08-18 | Routine/Complete Inspection | No Violations Noted | |
2301892 | Primary Facility | 2014-08-22 | Routine/Complete Inspection | Pending | |
2376461 | Primary Facility | 2015-06-05 | Site Restoration | No Violations Noted | Notice of Termination received 6/4/15. Site is permanently stabilized, temporary E&S controls have been removed & PCSM BMPs are installed. Recommend approval of the NOT. TLT |
2439091 | Primary Facility | 2016-01-05 | Site Restoration | No Violations Noted | Recommending approval of NOT. Pad ~ 1.4 acres. 8 Marcellus natural gas wells producing. |
2554411 | Primary Facility | 2017-01-23 | Routine/Complete Inspection | No Violations Noted | |
2707682 | Primary Facility | 2018-03-19 | Routine/Complete Inspection | No Violations Noted | Cold/windy at time of inspection
Cellar is frozen at time of inspection |
2752934 | Primary Facility | 2018-06-04 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was not producing. This inspection was conducted as part of a pressure build up test. The 9x13 and the 13x20 annulus vents were shut-in on Friday 6-1-18 when the Transducers were installed. The 5x9 annulus vent was connected and venting to a poly tank on location. The 5x9 annulus vent for the other wells on this pad were also connected to this poly tank. The tank was tested with a Altair 5x multi gas meter calibrated on 6-4-18 for combustable gas with the results being 25% LEL( lower explosion limit) and 0% Methane/ by volume at the time of this inspection. 0 psi( pounds per square inch) was observed on the gauge for the 13x20 annulus vent , 0 psi( pounds per square inch) was observed on the gauge for the 9x13 annulus vent and 0 psi( pounds per square inch ) was observed on the 5x9
annulus vent. No violations noted at the time of this inspection. |
2753349 | Primary Facility | 2018-06-07 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection this well was not producing. This inspection was conducted as part of a pressure build up test that began on 6-4-18.The 5x9 annulus vent was connected to a poly tank on location. The 5x9 annulus vent for the other wells on this pad were also connected to this poly tank. The tank was tested with a Altair 5x multi gas meter calibrated on 6-7-18 for combustable gas with the results being 0 LEL(lower explosion limit) and 0 Methane.0 pounds per square inch) was observed on the gauge for the 13x20 annulus vent,1 psi( pounds per square inch) was observed on the gauge for the 9x13 annulus vent and 15 psi( pounds per square inch) was observed on the gauge for the 5x9 annulus vent. At the time of this inspection a split gas sample with Moody and Associates was collected on the 9 x 13 and the 5x9 annulus vent at 11:38am. No violations were noted at the time of this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
1966383 | 609037 | 04/18/2011 | 2011-04-18 | 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. | Environmental Health & Safety | |
1966383 | 609038 | 04/18/2011 | 2011-04-18 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | |
1966383 | 609044 | 04/18/2011 | 2011-04-18 | 78.66A - Failure to report release of substance threatening or causing pollution | Administrative |
For data sources see[8]