37-117-21162

Well Details

Well ID: 37-117-21162
Loading map...
Country: United States
State: Pennsylvania
County: Tioga
Municipality: Covington Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 149489
Farm/Lease Name: VALLDES 1H R 50496
License Status:
Spud Date:
Permit Date: 2011-01-26
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.739281
Longitude: -77.104496

For data sources see[1][2][3]

Well History

Date Event
2011-01-26 New Permit Application
2011-03-08 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-06-18 2011-06-18 6,106 4,028,430

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Unigel CMHPG Guar Product Universal Well Services Gelling Agent No Hazardous Components 0.00
NE-90 Universal Well Services Non-Emulsifier Isopropanol 67-63-0 10.00 0.00002000
Alcohols, C7-9-iso-, C8-rich, ethoxylated 78330-19-5 5.00 0.00001000
Polyethylene glycol 25322-68-3 5.00 0.00001000
Solvent naphtha, petroleum, heavy arom. 64742-94-5 5.00 0.00001000
Alcohols, C9-11-iso-, C10-rich, ethoxylated 78330-20-8 5.00 0.00001000
2-Ethylhexanol 104-76-7 10.00 0.00002000
Naphthalene 91-20-3 1.00 0.00
Methanol 67-56-1 60.00 0.00012000
Iron Sta IIC Universal Well Services Iron Control Ethylene glycol 107-21-1 30.00 0.00024000
32 Hydrochloric Acid Universal Well Services Acid Hydrochloric acid 7647-01-0 32.00 0.03
Unislik ST 50 Universal Well Services Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.01
BioRid 20L Tetra Biocide Sodium bromide 7647-15-6 15.00 0.00187000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 20.00 0.00249000
Sand (Proppant) Universal Well Services Proppant Quartz 14808-60-7 99.90 12.23
LEB-10X Universal Well Services Enzyme Breaker Ethylene glycol 107-21-1 60.00 0.00001000
Unihib A Universal Well Services Corrosion Inhibitor 1,2,4-Trimethylbenzene 95-63-6 5.00 0.00001000
Solvent naphtha, petroleum, light arom 64742-95-6 10.00 0.00002000
C10-C16 ethoxylated alcohol 68002-97-1 30.00 0.00006000
Naphtha, petroleum, heavy catalytic reformed 64741-68-0 10.00 0.00002000
Xylenes 1330-20-7 1.00 0.00
Diethylbenzene 25340-17-4 1.00 0.00
Methanol 67-56-1 30.00 0.00006000
Kerosine, petroleum, hydrodesulfurized 64742-81-0 5.00 0.00001000
Isomeric Aromatic Ammonium Salt 10.00 0.00002000
Cumene 98-82-8 1.00 0.00
Isopropanol 67-63-0 5.00 0.00001000
Formalin 50-00-0 1.00 0.00
Navy fuels JP-5 8008-20-6 5.00 0.00001000
Naphthalene 91-20-3 1.00 0.00
1,3,5-Trimethylbenzene 108-67-8 1.00 0.00
Distillates, petroleum, hydrotreated light 64742-47-8 5.00 0.00001000
2-substituted Aromatic Amine Salt 5.00 0.00001000
Water Universal Well Services Carrier/Base Fluid 87.63
ScaleHib 100 Universal Well Services Scale Inhibitor Ethylene glycol 107-21-1 60.00 0.01

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2011 SENECA RESOURCES CO LLC 244,434.00 149 0.00 0 0.00 0
2012 SENECA RESOURCES CO LLC 341,915.00 328 0.00 0 0.00 0
2013 SENECA RESOURCES CO LLC 244,405.00 323 0.00 0 0.00 0
2014 SENECA RESOURCES CO LLC 205,502.80 320 0.00 0 0.00 0
2015 SENECA RESOURCES CO LLC 111,252.49 233 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 31,278.12 50 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 45,890.26 68 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 149,121.15 300 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 142,376.12 356 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 SENECA RESOURCES CO LLC Drill Cuttings 4.22 Tons LANDFILL 100361
2011 SENECA RESOURCES CO LLC Drill Cuttings 149.97 Tons LANDFILL 8-4630-00010/00
2011 SENECA RESOURCES CO LLC Produced Fluid 20,328.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 SENECA RESOURCES CO LLC Drill Cuttings 790.60 Tons LANDFILL 100955
2011 SENECA RESOURCES CO LLC Fracing Fluid Waste 3,107.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 8,016.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 SENECA RESOURCES CO LLC Produced Fluid 19.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2013 SENECA RESOURCES CO LLC Produced Fluid 2,514.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 SENECA RESOURCES CO LLC Produced Fluid 411.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NC012
2013 SENECA RESOURCES CO LLC Produced Fluid 896.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 16.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NC012
2014 SENECA RESOURCES CO LLC Produced Fluid 2,614.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 SENECA RESOURCES CO LLC Produced Fluid 213.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2015 SENECA RESOURCES CO LLC Produced Fluid 38.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2015 SENECA RESOURCES CO LLC Produced Fluid 987.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Produced Fluid 52.53 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 115.20 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 205.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid 754.51 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Produced Fluid 696.27 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 48.75 Bbl REUSE (AT WELL PAD)
2019 SENECA RESOURCES CO LLC Produced Fluid 119.38 Bbl RESIDUAL WASTE TRANSFER FACILITY WMGR123NC039
2019 SENECA RESOURCES CO LLC Produced Fluid 307.52 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 15.00 Bbl STORAGE PENDING DISPOSAL OR REUSE WMGR123NC038
2019 SENECA RESOURCES CO LLC Produced Fluid 43.13 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC003
2019 SENECA RESOURCES CO LLC Produced Fluid 443.66 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1958349 Primary Facility 2011-03-18 Drilling/Alteration No Violations Noted
1966383 Primary Facility 2011-04-18 Drilling/Alteration Violation(s) Noted
1990058 Primary Facility 2011-06-14 Compliance Evaluation No Violations Noted 1H 2H cellars bubbling. Flowback pit onsite
1999765 Primary Facility 2011-07-27 Routine/Complete Inspection No Violations Noted
1999767 Primary Facility 2011-08-03 Routine/Complete Inspection No Violations Noted
2136328 Primary Facility 2013-02-04 Routine/Complete Inspection No Violations Noted
2136354 Primary Facility 2013-02-04 Plugging(Includes Plugged/Mined Through) No Violations Noted
2144609 Primary Facility 2013-03-01 Routine/Complete Inspection No Violations Noted
2204355 Primary Facility 2013-09-09 Routine/Complete Inspection No Violations Noted
2248608 Primary Facility 2014-02-24 Routine/Complete Inspection No Violations Noted
2280286 Primary Facility 2014-06-02 Routine/Complete Inspection No Violations Noted
2280379 Primary Facility 2014-06-06 Routine/Complete Inspection Pending Gas detected outside surface casing following PBT. VIOLs pending analytical results
2298598 Primary Facility 2014-08-18 Routine/Complete Inspection No Violations Noted
2301892 Primary Facility 2014-08-22 Routine/Complete Inspection Pending
2376461 Primary Facility 2015-06-05 Site Restoration No Violations Noted Notice of Termination received 6/4/15. Site is permanently stabilized, temporary E&S controls have been removed & PCSM BMPs are installed. Recommend approval of the NOT. TLT
2439091 Primary Facility 2016-01-05 Site Restoration No Violations Noted Recommending approval of NOT. Pad ~ 1.4 acres. 8 Marcellus natural gas wells producing.
2554411 Primary Facility 2017-01-23 Routine/Complete Inspection No Violations Noted
2707682 Primary Facility 2018-03-19 Routine/Complete Inspection No Violations Noted Cold/windy at time of inspection

Cellar is frozen at time of inspection

2752934 Primary Facility 2018-06-04 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was not producing. This inspection was conducted as part of a pressure build up test. The 9x13 and the 13x20 annulus vents were shut-in on Friday 6-1-18 when the Transducers were installed. The 5x9 annulus vent was connected and venting to a poly tank on location. The 5x9 annulus vent for the other wells on this pad were also connected to this poly tank. The tank was tested with a Altair 5x multi gas meter calibrated on 6-4-18 for combustable gas with the results being 25% LEL( lower explosion limit) and 0% Methane/ by volume at the time of this inspection. 0 psi( pounds per square inch) was observed on the gauge for the 13x20 annulus vent , 0 psi( pounds per square inch) was observed on the gauge for the 9x13 annulus vent and 0 psi( pounds per square inch ) was observed on the 5x9

annulus vent. No violations noted at the time of this inspection.

2753349 Primary Facility 2018-06-07 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was not producing. This inspection was conducted as part of a pressure build up test that began on 6-4-18.The 5x9 annulus vent was connected to a poly tank on location. The 5x9 annulus vent for the other wells on this pad were also connected to this poly tank. The tank was tested with a Altair 5x multi gas meter calibrated on 6-7-18 for combustable gas with the results being 0 LEL(lower explosion limit) and 0 Methane.0 pounds per square inch) was observed on the gauge for the 13x20 annulus vent,1 psi( pounds per square inch) was observed on the gauge for the 9x13 annulus vent and 15 psi( pounds per square inch) was observed on the gauge for the 5x9 annulus vent. At the time of this inspection a split gas sample with Moody and Associates was collected on the 9 x 13 and the 5x9 annulus vent at 11:38am. No violations were noted at the time of this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
1966383 609037 04/18/2011 2011-04-18 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety
1966383 609038 04/18/2011 2011-04-18 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
1966383 609044 04/18/2011 2011-04-18 78.66A - Failure to report release of substance threatening or causing pollution Administrative

For data sources see[8]