If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21293 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.687319,"lon":-77.078928,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Blossburg Borough | |
Operator Name: SENECA RESOURCES CO LLC | |
Well Pad ID: 148214 | |
Farm/Lease Name: DCNR 595 PAD E 10H 50179 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-07-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.687319 | |
Longitude: -77.078928 |
Date | Event |
---|---|
2011-07-22 | New Permit Application |
2011-08-23 | Performed Spud Operation |
2011-12-15 | New Permit Application |
2012-01-24 | Drilling Completion |
2012-05-03 | Perforation |
2012-12-13 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-05-27 | 2012-05-27 | 8,000 | 7,278,180 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | CFT-1300 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00000159 | |
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000018 | ||||||
Proppant 30/50 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.04 | ||
Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.00028497 | ||
CFT-2500 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00000030 | ||
Proprietary Ingredient supplied as 10 w/v | 10.00 | 0.00000003 | ||||||
Aqueous Solution | ||||||||
Proppant 40/70 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.04 | ||
CFT-1500 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00000070 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000008 | ||||||
CFT-1200 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000015 | |||
Water | 7732-18-5 | 90.00 | 0.00000136 | |||||
Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.00195641 | ||
15 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00008903 | ||
CFT-1000 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00000145 | ||
Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000016 | ||||||
7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.00043675 | ||
CFT-1700 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00000007 | |||
Water | 7732-18-5 | 90.00 | 0.00000062 | |||||
Unihib G | Universal Well Services | Corrosion Inhibitor | Ethoxylated Alcohol | 35.00 | 0.00000094 | |||
Resin Based Nonionic Inhibitor | 35.00 | 0.00000094 | ||||||
Diethylene glycol monobutyl ether | 112-34-5 | 50.00 | 0.00000134 | |||||
BioRid 20L | Tetra | Biocide | 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00002370 | ||
Sodium bromide | 7647-15-6 | 15.00 | 0.00001777 | |||||
ScaleHib 100 | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 60.00 | 0.00007776 | ||
Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00000317 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SENECA RESOURCES CO LLC | 828,264.00 | 162 | 0.00 | 0 | 0.00 | 0 |
2013 | SENECA RESOURCES CO LLC | 1,461,813.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | SENECA RESOURCES CO LLC | 951,607.50 | 316 | 0.00 | 0 | 0.00 | 0 |
2015 | SENECA RESOURCES CO LLC | 504,561.18 | 131 | 0.00 | 0 | 0.00 | 0 |
2016 | SENECA RESOURCES CO LLC | 504,992.51 | 147 | 0.00 | 0 | 0.00 | 0 |
2017 | SENECA RESOURCES CO LLC | 746,831.77 | 358 | 0.00 | 0 | 0.00 | 0 |
2018 | SENECA RESOURCES CO LLC | 528,402.20 | 353 | 0.00 | 0 | 0.00 | 0 |
2019 | SENECA RESOURCES CO LLC | 440,374.31 | 361 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 764.55 Tons | LANDFILL | 301358 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 592.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 6,995.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 88.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
2012 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 1.57 Tons | LANDFILL | 301358 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 13.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24072 |
2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 2,439.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 88.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 89.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 159.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 39.00 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2012 | SENECA RESOURCES CO LLC | Drill Cuttings | 356.27 Tons | LANDFILL | 301358 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 605.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 609.00 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
2012 | SENECA RESOURCES CO LLC | Produced Fluid | 304.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 2,081.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 16.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
2013 | SENECA RESOURCES CO LLC | Produced Fluid | 171.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
2014 | SENECA RESOURCES CO LLC | Produced Fluid | 464.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 131.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2015 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 40.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SENECA RESOURCES CO LLC | Produced Fluid | 156.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 90.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2016 | SENECA RESOURCES CO LLC | Produced Fluid | 141.17 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 252.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 19.17 Bbl | REUSE (AT WELL PAD) | |
2017 | SENECA RESOURCES CO LLC | Produced Fluid | 474.26 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 245.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | REUSE (AT WELL PAD) | |
2018 | SENECA RESOURCES CO LLC | Produced Fluid | 319.18 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 149.19 Bbl | REUSE (AT WELL PAD) | |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 84.17 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
2019 | SENECA RESOURCES CO LLC | Produced Fluid | 171.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2009853 | Primary Facility | 2011-10-11 | Routine/Complete Inspection | No Violations Noted | access road sediment runoff into state forest. viols charged to 13H |
2068600 | Primary Facility | 2012-05-16 | Follow-up Inspection | No Violations Noted | |
2068846 | Primary Facility | 2012-05-16 | Follow-up Inspection | No Violations Noted | closing E&S viols. fracking 6 gas wells |
2073983 | Primary Facility | 2012-06-01 | Compliance Evaluation | No Violations Noted | frackin, 10 brl frack fluid release from valve under pressure |
2253290 | Primary Facility | 2014-03-11 | Incident- Response to Accident or Event | No Violations Noted | Production liquid leaked out behind separators when flange developed hole. Violations cited to escgp |
2312589 | Primary Facility | 2014-10-14 | Follow-up Inspection | No Violations Noted | Clossing violations from 11 MAR 2014, when production liquid leaked out of flow line. |
2592664 | Primary Facility | 2017-05-03 | Routine/Partial Inspection | No Violations Noted | This is an inspection of DCNR 595 Pad E.
Electrical conductivity readings w an Oakton PCSTestr 35: production tank containment--0.13 mS/cm, separator containment--0.15 mS/cm, pad--1.2 mS/cm. Onsite during this inspection were 2 Seneca workers tending to the separators. The basin down gradient of the pad (photo) is not on the plan drawing. The basin along the access road (photo) is listed as a "rain garden" on the plan. Time: ~1500-1555 hrs |
2820638 | Primary Facility | 2018-12-28 | Site Restoration | No Violations Noted | This inspection covers DCNR 595 Pad E (not Pads C & G).
NOT denied. Slopes around the pad are temporarily stabilized with hydroseed and sparse vegetation (photo 2). Filter sock (photo 1) is considered a temporary E & S control and hydro seed temporary stabilization; ESCGP termination requires "permanent stabilization", and removal of temporary E & S controls. I took electrical conductivity readings from pooled water on site with an Oakton PCSTestr 35. A puddle near the production tanks returned 0.17 mS/cm. Air temp: 45F JLP |
For data sources see[8]