If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-117-21296 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.687608,"lon":-77.078933,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Tioga | |
| Municipality: Blossburg Borough | |
| Operator Name: SENECA RESOURCES CO LLC | |
| Well Pad ID: 148214 | |
| Farm/Lease Name: DCNR 595 PAD E 13H 50182 | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2011-07-22 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.687608 | |
| Longitude: -77.078933 |
| Date | Event |
|---|---|
| 2011-07-22 | New Permit Application |
| 2011-08-20 | Performed Spud Operation |
| 2012-01-08 | Drilling Completion |
| 2012-05-03 | Perforation |
| 2012-12-13 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2012-06-05 | 2012-06-05 | 7,839 | 8,459,640 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | 15 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00863000 | |
| Proppant 30/50 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 3.99 | ||
| CFT-2200 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00001000 | |||
| Water | 7732-18-5 | 90.00 | 0.00012000 | |||||
| BioRid 20L | Tetra | Biocide | Sodium bromide | 7647-15-6 | 15.00 | 0.00178000 | ||
| 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 20.00 | 0.00237000 | |||||
| 7.5 HydroChloric Acid | Universal Well Services | Acid | Hydrochloric acid | 7647-01-0 | 7.50 | 0.06 | ||
| CFT-1000 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00001000 | |||
| Water | 7732-18-5 | 90.00 | 0.00006000 | |||||
| Unihib G | Universal Well Services | Corrosion Inhibitor | Ethoxylated Alcohol | 35.00 | 0.00013000 | |||
| Resin Based Nonionic Inhibitor | 35.00 | 0.00013000 | ||||||
| Diethylene glycol monobutyl ether | 112-34-5 | 50.00 | 0.00019000 | |||||
| ScaleHib 100 | Universal Well Services | Scale Inhibitor | Ethylene glycol | 107-21-1 | 60.00 | 0.00771000 | ||
| Iron Stabilizer II | Universal Well Services | Corrosion Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00045000 | ||
| CFT-1100 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00017000 | ||
| Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00002000 | ||||||
| Proppant 80/100 Oklahoma | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 0.16 | ||
| CFT-1700 | Core Laboratories | Chemical Tracer | Water | 7732-18-5 | 90.00 | 0.00011000 | ||
| Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00001000 | ||||||
| CFT-1400 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00 | |||
| Water | 7732-18-5 | 90.00 | 0.00002000 | |||||
| Unislik ST 50 | Universal Well Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.02 | ||
| CFT-2100 | Core Laboratories | Chemical Tracer | Proprietary Ingredient supplied as 10 w/v Aqueous Solution | 10.00 | 0.00001000 | |||
| Water | 7732-18-5 | 90.00 | 0.00010000 | |||||
| Proppant 40/70 Ottawa | Universal Well Services | Proppant | Quartz | 14808-60-7 | 100.00 | 3.91 |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2011 | SENECA RESOURCES CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2012 | SENECA RESOURCES CO LLC | 906,630.00 | 170 | 0.00 | 0 | 0.00 | 0 |
| 2013 | SENECA RESOURCES CO LLC | 1,460,015.00 | 364 | 0.00 | 0 | 0.00 | 0 |
| 2014 | SENECA RESOURCES CO LLC | 827,736.00 | 284 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SENECA RESOURCES CO LLC | 583,373.67 | 164 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SENECA RESOURCES CO LLC | 14,875.82 | 18 | 0.00 | 0 | 0.00 | 0 |
| 2017 | SENECA RESOURCES CO LLC | 353,250.86 | 361 | 0.00 | 0 | 0.00 | 0 |
| 2018 | SENECA RESOURCES CO LLC | 308,357.64 | 365 | 0.00 | 0 | 0.00 | 0 |
| 2019 | SENECA RESOURCES CO LLC | 286,609.86 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2011 | SENECA RESOURCES CO LLC | Drill Cuttings | 709.23 Tons | LANDFILL | 301358 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 838.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
| 2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 162.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 10,654.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 125.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21893 |
| 2012 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 1.58 Tons | LANDFILL | 301358 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 19.00 Bbl | INJECTION DISPOSAL WELL | 34-083-24072 |
| 2012 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 2,441.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 125.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21894 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 125.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23203 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 225.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23795 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 57.00 Bbl | INJECTION DISPOSAL WELL | 34-151-23420 |
| 2012 | SENECA RESOURCES CO LLC | Drill Cuttings | 276.02 Tons | LANDFILL | 301358 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 857.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
| 2012 | SENECA RESOURCES CO LLC | Produced Fluid | 430.00 Bbl | INJECTION DISPOSAL WELL | 34-133-20525 |
| 2013 | SENECA RESOURCES CO LLC | Produced Fluid | 2,525.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013 | SENECA RESOURCES CO LLC | Produced Fluid | 20.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC012 |
| 2013 | SENECA RESOURCES CO LLC | Fracturing Fluid Waste | 15.01 Tons | LANDFILL | 301358 |
| 2013 | SENECA RESOURCES CO LLC | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC012 |
| 2014 | SENECA RESOURCES CO LLC | Produced Fluid | 907.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2015 | SENECA RESOURCES CO LLC | Produced Fluid | 630.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2015 | SENECA RESOURCES CO LLC | Fracing Fluid Waste | 40.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015 | SENECA RESOURCES CO LLC | Produced Fluid | 473.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SENECA RESOURCES CO LLC | Produced Fluid | 90.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2016 | SENECA RESOURCES CO LLC | Produced Fluid | 141.17 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NW011 |
| 2017 | SENECA RESOURCES CO LLC | Produced Fluid | 253.25 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2017 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 19.17 Bbl | REUSE (AT WELL PAD) | |
| 2017 | SENECA RESOURCES CO LLC | Produced Fluid | 471.01 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SENECA RESOURCES CO LLC | Produced Fluid | 245.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
| 2018 | SENECA RESOURCES CO LLC | Other Oil & Gas Wastes | 18.33 Bbl | REUSE (AT WELL PAD) | |
| 2018 | SENECA RESOURCES CO LLC | Produced Fluid | 319.18 Bbl | REUSE (AT WELL PAD) | |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 149.19 Bbl | REUSE (AT WELL PAD) | |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 84.17 Bbl | RESIDUAL WASTE TRANSFER FACILITY | WMGR123NC039 |
| 2019 | SENECA RESOURCES CO LLC | Produced Fluid | 171.68 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2009846 | Primary Facility | 2011-10-11 | Routine/Complete Inspection | Violation(s) Noted | access road sediment runoff goin into state forest |
| 2032597 | Primary Facility | 2012-01-05 | Drilling/Alteration | No Violations Noted | |
| 2068418 | Primary Facility | 2012-05-16 | Follow-up Inspection | No Violations Noted | |
| 2073986 | Primary Facility | 2012-06-01 | Compliance Evaluation | No Violations Noted | frackin, 10 brl frack fluid release from valve under pressure |
| 2253293 | Primary Facility | 2014-03-11 | Incident- Response to Accident or Event | No Violations Noted | Production liquid leaked out behind separators when flange developed hole. Violations cited to escgp |
| 2312585 | Primary Facility | 2014-10-14 | Follow-up Inspection | No Violations Noted | Clossing violations from 11 MAR 2014, when production liquid leaked out of flow line. |
| 2592681 | Primary Facility | 2017-05-03 | Routine/Partial Inspection | No Violations Noted | This is an inspection of DCNR 595 Pad E.
Electrical conductivity readings w an Oakton PCSTestr 35: production tank containment--0.13 mS/cm, separator containment--0.15 mS/cm, pad--1.2 mS/cm. Onsite during this inspection were 2 Seneca workers tending to the separators. The basin down gradient of the pad (photo) is not on the plan drawing. The basin along the access road (photo) is listed as a "rain garden" on the plan. Time: ~1500-1555 hrs |
| 2820644 | Primary Facility | 2018-12-28 | Site Restoration | No Violations Noted | This inspection covers DCNR 595 Pad E (not Pads C & G).
NOT denied. Slopes around the pad are temporarily stabilized with hydroseed and sparse vegetation (photo 2). Filter sock (photo 1) is considered a temporary E & S control and hydro seed temporary stabilization; ESCGP termination requires "permanent stabilization", and removal of temporary E & S controls. I took electrical conductivity readings from pooled water on site with an Oakton PCSTestr 35. A puddle near the production tanks returned 0.17 mS/cm. Air temp: 45F JLP |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2009846 | 621980 | 10/11/2011 | 2011-10-11 | 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) | Environmental Health & Safety | |
| 2009846 | 621981 | 10/11/2011 | 2011-10-11 | 102.4NOPLAN - No E&S plan developed, plan not on site | Administrative |
For data sources see[8]