If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
| Well ID: 37-117-21383 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.584731,"lon":-76.998108,"icon":""}]} |
| Country: United States | |
| State: Pennsylvania | |
| County: Tioga | |
| Municipality: Union Township | |
| Operator Name: ROCKDALE MARCELLUS LLC | |
| Well Pad ID: 147973 | |
| Farm/Lease Name: COCHRAN T 705 5H | |
| License Status: | |
| Spud Date: | |
| Permit Date: 2011-11-21 | |
| Well Type: GAS | |
| Unconventional Well: Y | |
| Configuration: Horizontal Well | |
| Conservation: No | |
| Latitude: 41.584731 | |
| Longitude: -76.998108 |
| Date | Event |
|---|---|
| 2011-11-21 | New Permit Application |
| 2011-12-17 | Performed Spud Operation |
| 2012-03-06 | Drilling Completion |
| 2012-07-20 | DEVIATED |
For data sources see[4]
| Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
|---|---|---|---|---|---|
| 1 | 2012-05-16 | 2012-05-16 | 5,498 | 3,403,848 |
| Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
|---|---|---|---|---|---|---|---|---|
| 1 | Friction Reducer | CESI Chemical | Reduce psi and HHP | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.01 | |
| Acid | Various | Opens Perfs | Hydrochloric acid | 7647-01-0 | 15.00 | 0.00553000 | ||
| Enzymatic Breaker | Clearwater International | Breaks Gel | Ethylene glycol | 107-21-1 | 60.00 | 0.00001000 | ||
| Gel | Clearwater International | Adds Viscosity to Water | Fumaric acid | 110-17-8 | 7.00 | 0.00008000 | ||
| Scale Inhibitor | Clearwater International | Prevents Scale | Ethylene glycol | 107-21-1 | 40.00 | 0.01 | ||
| Sand | Various | Proppagates Frac | Quartz | 14808-60-7 | 100.00 | 16.80 | ||
| Biocide | Nalco | Kills Bacteria | Polyethylene glycol | 25322-68-3 | 60.00 | 0.00594000 | ||
| 2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00297000 | |||||
| Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00050000 | |||||
| Acid Inhibitor | Clearwater International | Protects Steel | Propargyl alcohol | 107-19-7 | 40.00 | 0.00031000 | ||
| Isopropanol | 67-63-0 | 40.00 | 0.00031000 | |||||
| 2-Butoxyethanol | 111-76-2 | 40.00 | 0.00031000 | |||||
| Ethoxylated Nonylphenol | 13.00 | 0.00010000 | ||||||
| Water / Produced Water | Shell | Carrier Fluid | H2O + Disolved Salts | 100.00 | 83.05 |
For data sources see[5]
| Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
|---|---|---|---|---|---|---|---|
| 2011 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
| 2012 | SWEPI LP | 100,249.75 | 109 | 0.00 | 0 | 0.00 | 0 |
| 2013 | SWEPI LP | 80,915.25 | 182 | 0.00 | 0 | 0.00 | 0 |
| 2014 | SWEPI LP | 21,726.32 | 36 | 0.00 | 0 | 0.00 | 0 |
| 2015 | SWEPI LP | 18,700.89 | 15 | 0.00 | 0 | 0.00 | 0 |
| 2016 | SWEPI LP | 20,193.38 | 19 | 0.00 | 0 | 0.00 | 0 |
| 2017 | SWEPI LP | 6,566.05 | 5 | 0.00 | 0 | 0.00 | 0 |
| 2019 | ROCKDALE MARCELLUS LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
| Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
|---|---|---|---|---|---|
| 2012 | SWEPI LP | Produced Fluid | 136.67 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
| 2012 | SWEPI LP | Fracing Fluid Waste | 0.40 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PAD987266749 |
| 2012 | SWEPI LP | Drill Cuttings | 546.32 Tons | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123NC006 |
| 2012 | SWEPI LP | Produced Fluid | 148.48 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012 | SWEPI LP | Fracing Fluid Waste | 0.40 Bbl | CENT WASTE TRT FAC NPDES | PAD987266749 |
| 2012 | SWEPI LP | Fracing Fluid Waste | 483.96 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
| 2012 | SWEPI LP | Fracing Fluid Waste | 4,452.26 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2012 | SWEPI LP | Fracing Fluid Waste | 33.33 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
| 2012 | SWEPI LP | Fracing Fluid Waste | 823.33 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
| 2013 | SWEPI LP | Produced Fluid | 6,080.93 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2013 | SWEPI LP | Produced Fluid | 242.76 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2013 | SWEPI LP | Fracing Fluid Waste | 52.98 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | SWEPI LP | Produced Fluid | 805.02 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2014 | SWEPI LP | Produced Fluid | 3.33 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
| 2014 | SWEPI LP | Produced Fluid | 138.12 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
| 2015 | SWEPI LP | Produced Fluid | 300.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
| 2015 | SWEPI LP | Produced Fluid | 214.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SWEPI LP | Other Oil & Gas Wastes | 62.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2016 | SWEPI LP | Produced Fluid | 570.33 Bbl | REUSE OTHER THAN ROAD SPREADING | |
| 2016 | SWEPI LP | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
| 2017 | SWEPI LP | Produced Fluid | 133.33 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
| 2017 | SWEPI LP | Produced Fluid | 81.00 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ROCKDALE MARCELLUS LLC | Synthetic Liner Materials | 6.58 Tons | LANDFILL | 301358 |
| 2019 | ROCKDALE MARCELLUS LLC | Drilling Fluid Waste | 37.28 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
| 2019 | ROCKDALE MARCELLUS LLC | Produced Fluid | 432.84 Bbl | STORAGE PENDING DISPOSAL OR REUSE | WMGR123NC036 |
| 2019 | ROCKDALE MARCELLUS LLC | Drilling Fluid Waste | 39.29 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ROCKDALE MARCELLUS LLC | Other Oil & Gas Wastes | 168.58 Bbl | STORAGE PENDING DISPOSAL OR REUSE | WMGR123NC036 |
| 2019 | ROCKDALE MARCELLUS LLC | Other Oil & Gas Wastes | 78.57 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ROCKDALE MARCELLUS LLC | Produced Fluid | 681.42 Bbl | REUSE (AT WELL PAD) | |
| 2019 | ROCKDALE MARCELLUS LLC | Soil Contaminated by Oil | 1.55 Tons | LANDFILL | 301358 |
| 2019 | ROCKDALE MARCELLUS LLC | Soil Contaminated by Oil & Gas Related Spills | 1.55 Tons | LANDFILL | 301358 |
| 2019 | ROCKDALE MARCELLUS LLC | Produced Fluid | 29.79 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
For data sources see[7]
| Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
|---|---|---|---|---|---|
| 2047661 | Primary Facility | 2012-03-01 | Drilling/Alteration | No Violations Noted | |
| 2070574 | Primary Facility | 2012-05-14 | Follow-up Inspection | Violation(s) Noted | |
| 2376335 | Primary Facility | 2015-06-02 | Routine/Complete Inspection | No Violations Noted | Overall vegetative cover on site >70%. Some silt fence is still in place around the perimeter of the site. The fences observed were in disrepair and falling over. These fences should either be maintained or removed. |
| 2420406 | Primary Facility | 2015-10-20 | Site Restoration | No Violations Noted | |
| 2668462 | Primary Facility | 2017-12-07 | Routine/Complete Inspection | No Violations Noted | Inspection to assess overall site conditions. No violations cited. |
| 2841688 | Primary Facility | 2019-02-19 | Routine/Complete Inspection | No Violations Noted | Routine inspection conducted to assess overall site conditions. Site was snow-covered at the time of inspection. Three wells are staged for production. A fourth well head is present but is not staged for production. Each well has a well tag which says Shell Appalachia instead of Rockdale. The Department recommends replacing the well tags. Three GPUs are present and in good condition. One steel double-walled production tank is present and in good condition. A faded produced water label is present on the produced water tank.
No violations noted. |
| Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
|---|---|---|---|---|---|---|
| 2070574 | 640102 | 05/14/2012 | 2012-05-14 | 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. | Environmental Health & Safety | Flowback spill while fracking the 5H well. Baker tank on containment failed and spilled into containment. Containment was overwhelmed and spilled material slowed off the pad, into a rock-lined ditch, and into the sed. basin. Remediation report recd 11/5/2012 |
| 2070574 | 640103 | 05/14/2012 | 2012-05-14 | 78.56(1) - Pit and tanks not constructed with sufficient capacity to contain pollutional substances. | Administrative | Flowback spill while fracking the 5H well. Baker tank on containment failed and spilled into containment. Containment was overwhelmed and spilled material slowed off the pad, into a rock-lined ditch, and into the sed. basin. Remediation report recd 11/5/2012 |
| 2070574 | 640104 | 05/14/2012 | 2012-05-14 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Flowback spill while fracking the 5H well. Baker tank on containment failed and spilled into containment. Containment was overwhelmed and spilled material slowed off the pad, into a rock-lined ditch, and into the sed. basin. Remediation report recd 11/5/2012 |
For data sources see[8]