If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21428 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.940022,"lon":-77.014225,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Jackson Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 146197 | |
Farm/Lease Name: YOUST R 405 1H | |
License Status: Plugged and Abandoned | |
Spud Date: 2012-02-13 | |
Permit Date: 2012-01-26 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.940022 | |
Longitude: -77.014225 |
Date | Event |
---|---|
2012-01-26 | New Permit Application |
2012-02-10 | Performed Spud Operation |
2012-05-21 | Drilling Completion |
2012-12-13 | Deviated |
2014-01-16 | Inactive Well Request Granted |
2017-10-27 | Begin Plugging |
2017-11-07 | Finished Plugging |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2014 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SWEPI LP | Fracing Fluid Waste | 0.57 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PAD987266749 |
2012 | SWEPI LP | Drilling Fluid Waste | 60.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123 |
2012 | SWEPI LP | Fracing Fluid Waste | 0.57 Bbl | CENT WASTE TRT FAC NPDES | PAD987266749 |
2012 | SWEPI LP | Fracing Fluid Waste | 111.90 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | SWEPI LP | Fracing Fluid Waste | 111.90 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW018 |
2012 | SWEPI LP | Drill Cuttings | 529.51 Tons | LANDFILL | 8-4630-00010/00 |
2013 | SWEPI LP | Produced Fluid | 302.38 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | SWEPI LP | Produced Fluid | 2.38 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWEPI LP | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017 | SWEPI LP | Produced Fluid | 100.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2068697 | Primary Facility | 2012-05-17 | Drilling/Alteration | No Violations Noted | |
2149841 | Primary Facility | 2013-03-15 | Routine/Complete Inspection | No Violations Noted | 1 gas well; large pad |
2301743 | Primary Facility | 2014-08-27 | Routine/Complete Inspection | No Violations Noted | |
2644514 | Primary Facility | 2017-10-06 | Routine/Complete Inspection | No Violations Noted | Routine pre-plug inspection of a gas well. The well was shut-in w/ master valve on b-section. Cellar below b-section filled w/gravel with four annular vents observable at surface. No obvious major issues were observed at surface. |
2651924 | Primary Facility | 2017-10-25 | Routine/Complete Inspection | No Violations Noted | Routine inspection of a well pre-plugging. Well is shut in with master valve on B section and cap. The cellar was full of gravel with standing water on top. No bubbling was observed in the water. There were four vent pipes to surface: two 2" inch vent pipes, a 1 inch vent pipe and one 1 1/2" inch vent pipe. I could not see where the vent pipes were coming from or if they were open in the cellar because the cellar was full of gravel.The operator intends to begin plugging tomorrow according to the notice of intent to plug submitted. No obvious major issues were observed. |
2656265 | Primary Facility | 2017-11-01 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig on location for P&A. The crew has just rigged up. The is dead. I spoke with the companyman and discussed tentative procedure. They'll drill out bridge plug at 3000', run in to 5600' to set a CIBP below the tully, cmt and recover production csg above TOC and plug remainder of well. No issues observed. |
2658083 | Primary Facility | 2017-11-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Rig on location for P&A which has just been completed. I spoke with the Company man and discussed operations. No issues reported. I walked over to well to inspect; 5 1/2" was recovered from 2810', I looked down in the 9 5/8"'casing and checked w/ Altair 5x gas meter. No issues observed, no gas was detected with an Altair 5x gas meter. I discussed depth of plugs with the Companyman. CIBP set at 5600, capped with cement back to 5400', gelled uphole , plugged back with cement from 4100' to 4376', cut and pulled casing at 2810 and plugged back from stub to 2365', spotted cement across surface shoe ( inside 9 5/8"). The well will be cut, capped, and buried below surface. |
2662653 | Primary Facility | 2017-11-20 | Administrative/File Review | No Violations Noted | November 20, 2017: Certificate of Well Plugging for the Youst 405 1H (117-21428) has been received, reviewed, signed, and sent to file. |
2679970 | Primary Facility | 2018-01-09 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of a recently plugged well. The well is cut, capped, and buried below ground level. No methane was detected at ground level at the well's surface location. No obvious issues were observed. |
2786910 | Primary Facility | 2018-10-10 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Routine inspection of an unconventional well plugged last year. The plugged well has been cut and buried below ground level. There were no open holes, discharges, venting, or other obvious issues observed at the surface location of the plugged well. |
For data sources see[7]