If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21724 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.863867,"lon":-77.312819,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Middlebury Township | |
Operator Name: SWEPI LP | |
Well Pad ID: 145984 | |
Farm/Lease Name: CRUTTENDEN 846S 22H | |
License Status: | |
Spud Date: | |
Permit Date: 2014-07-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 41.863867 | |
Longitude: -77.312819 |
Date | Event |
---|---|
2014-07-25 | New Permit Application |
2014-08-29 | Performed Spud Operation |
2014-12-15 | Drilling Completion |
2015-02-01 | Perforation |
2015-08-31 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-02-25 | 2015-03-14 | 11,213 | 6,292,430 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Other Chemicals | Acrylamide | 79-06-1 | 0 | 0.000407271 | 0 | ||
Sodium Chloride | 7647-14-5 | 0 | 0.00203636 | 0 | ||||
Ethylene Oxide | 75-21-8 | 0 | 0.00000889 | 0 | ||||
Acetaldehyde | 75-07-0 | 0 | 0.00000889 | 0 | ||||
Dioxane | 123-91-1 | 0 | 0.00000889 | 0 | ||||
Phosphonic acid ammonium salt | Mixture | 0 | 0.00036872 | 0 | ||||
Amides, Tall- Oil Fatty, N, N-Bis(Hydroxyethyl) | 68155-20-4 | 0 | 0.00203636 | 0 | ||||
Cinnamaldehyde | 104-55-2 | 0 | 0.00004445 | 0 | ||||
Polyoxyethylene sorbitan monooleate | 9005-65-6 | 0 | 0.000407271 | 0 | ||||
2-PROPENAMIDE, POLYMER WITH 2-PROPENOIC ACID AND SODIUM 2-PROPENOATE |
62649-23-4 | 0 | 0.0122181 | 0 | ||||
Sorbitan Monoolite | 1338-43-8 | 0 | 0.000407271 | 0 | ||||
Water | Shell Exploration | Carrier / Base Fluid | Carrier / Base Fluid - Water | N/A | 100 | 87.1675 | 52,415,900.0 | |
WIC-641L | WFT | Iron Control | Citric acid | 77-92-9 | 60 | 0.0030907 | 3097.52 | |
WSI-685L | WFT | Inhibitor | Ammonium Chloride | 12125-02-9 | 15 | 0.00246383 | 9877.05 | |
Monoethanolamine Hydrochloride | 2002-24-6 | 15 | 0.00246383 | 9877.05 | ||||
Methyl Alcohol | 67-56-1 | 2.5 | 0.000410638 | 9877.05 | ||||
Friction Reducers | WFT | Friction Reducers | Petroleum distillates, hydrotreated light | 64742-47-8 | 40 | 0.205793 | 309370 | |
Ammonium acetate | 631-61-8 | 5 | 0.00257241 | 30937 | ||||
WAI-251LC | WFT | Inhibitor | Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00008890 | 534.572 | |
Ethoxylated Nonylphenol | 68412-54-4 | 5 | 0.00004445 | 534.572 | ||||
2-Butoxyethanol | 111-76-2 | 10 | 0.00008890 | 534.572 | ||||
Ethylene Glycol | 111-76-2 | 40 | 0.000355597 | 534.572 | ||||
N,N-Dimethylformamide | 68-12-2 | 20 | 0.000177798 | 534.572 | ||||
1-Octanol | 111-87-5 | 5 | 0.00004445 | 534.572 | ||||
1-Decanol | 112-30-1 | 5 | 0.00004445 | 534.572 | ||||
Triethylphosphate | 78-40-0 | 5 | 0.00004445 | 534.572 | ||||
Isopropyl Alcohol | 67-63-0 | 5 | 0.00004445 | 534.572 | ||||
WFR-61LA | WFT | Friction Reducer | Ammonium chloride | 12125-02-9 | 5 | 0.00203636 | 24490.2 | |
Petroleum Distillates | 64742-47-8 | 20 | 0.00814543 | 24490.2 | ||||
Alcohols, C12-16, Ethoxylated | 68551-12-2 | 5 | 0.00203636 | 24490.2 | ||||
15% HCL | WFT | Acid | Hydrochloric Acid | 7647-01-0 | 15 | 0.0707387 | 42536.9 | |
Ottawa Sand 40/70 (2.63 sg) | WFT | Proppant | Crystalline Silica in the form of Quartz | 14808-60-7 | 100 | 9.05818 | 5,446,900.0 | |
Bio- | WFT | Bactericide | Dibromoacetonitrile | 3252-43-5 | 0.5 | 0.000118535 | 14255.6 | |
Sodium Bromide | 7647-15-6 | 1.5 | 0.000355606 | 14255.6 | ||||
Polyethylene Glycol | 25322-68-3 | 65 | 0.0154096 | 14255.6 | ||||
2,2-dibromo-3-nitriloproppionamide | 10222-01-2 | 5 | 0.00118535 | 14255.6 | ||||
100 Mesh | WFT | Proppant | Crystalline Silica in the form of Quartz | 14808-60-7 | 100 | 3.10216 | 1,865,400.0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | SWEPI LP | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | SWEPI LP | 3,354,518.58 | 227 | 0.00 | 0 | 0.00 | 0 |
2016 | SWEPI LP | 2,068,088.83 | 364 | 0.00 | 0 | 0.00 | 0 |
2017 | SWEPI LP | 1,280,577.02 | 357 | 0.00 | 0 | 0.00 | 0 |
2018 | SWEPI LP | 848,719.84 | 334 | 0.00 | 0 | 0.00 | 0 |
2019 | SWEPI LP | 685,216.77 | 360 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | SWEPI LP | Fracing Fluid Waste | 7,269.72 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | SWEPI LP | Produced Fluid | 437.47 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SWEPI LP | Produced Fluid | 9,099.08 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWEPI LP | Fracing Fluid Waste | 4,173.19 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Fracing Fluid Waste | 2,023.54 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2015 | SWEPI LP | Produced Fluid | 450.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC010 |
2015 | SWEPI LP | Fracing Fluid Waste | 3,249.67 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2015 | SWEPI LP | Produced Fluid | 8,181.59 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | SWEPI LP | Waste Water Treatment Sludge | 12.36 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2016 | SWEPI LP | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC018 |
2016 | SWEPI LP | Produced Fluid | 449.96 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC018 |
2016 | SWEPI LP | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NC011 |
2016 | SWEPI LP | Produced Fluid | 82.49 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123 |
2016 | SWEPI LP | Produced Fluid | 12,141.83 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | SWEPI LP | Waste Water Treatment Sludge | 8.97 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SWEPI LP | Soil Contaminated by Oil | 15.50 Tons | LANDFILL | 301358 |
2017 | SWEPI LP | Soil Contaminated by Oil & Gas Related Spills | 15.50 Tons | LANDFILL | 301358 |
2017 | SWEPI LP | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | SWEPI LP | Produced Fluid | 1,425.97 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2017 | SWEPI LP | Produced Fluid | 6,839.59 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Drill Cuttings | 278.37 Tons | LANDFILL | 301358 |
2018 | SWEPI LP | Soil Contaminated by Oil | 0.01 Tons | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2018 | SWEPI LP | Soil Contaminated by Oil & Gas Related Spills | 0.01 Tons | RESIDUAL WASTE TRANSFER FACILITY | 7-3115-00193 |
2018 | SWEPI LP | Synthetic Liner Materials | 15.85 Tons | LANDFILL | 301358 |
2018 | SWEPI LP | Produced Fluid | 3,446.97 Bbl | REUSE (AT WELL PAD) | |
2018 | SWEPI LP | Produced Fluid | 150.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2018 | SWEPI LP | Waste Water Treatment Sludge | 11.32 Tons | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWEPI LP | Produced Fluid | 797.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | SWEPI LP | Produced Fluid | 200.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC022 |
2019 | SWEPI LP | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR119 |
2019 | SWEPI LP | Produced Fluid | 48.29 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWEPI LP | Produced Fluid | 393.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | SWEPI LP | Produced Fluid | 1,689.50 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2306513 | Primary Facility | 2014-09-17 | Routine/Complete Inspection | No Violations Noted | |
2307934 | Primary Facility | 2014-09-17 | Drilling/Alteration | No Violations Noted | |
2318985 | Primary Facility | 2014-10-03 | Follow-up Inspection | No Violations Noted | |
2332095 | Primary Facility | 2014-12-30 | Administrative/File Review | Violation(s) Noted | Admin inspection record entered for purpose of creating NOV record (Enf 318683) |
2335236 | Primary Facility | 2014-12-30 | Compliance Evaluation | Violation(s) Noted | NOV issued 12/30/2014 - Duplicate of insp 2332095, NOV is enf 318683 - See viol tab comments |
2346183 | Primary Facility | 2015-02-23 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | One barrel of production fluid released into containment and onto the ground on 2/19/15. Spill cleanup finished by morning of 2/22/15. Violations cited against 22H permit, but immediately corrected. Remediation report to be submitted to the Department. TLT |
2359754 | Primary Facility | 2015-04-07 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | Elevated soil conductivity on pad surface discovered 3/26/15. Excavation and confirmation sampling complete by 3/31/15. Standing water with elevated conductivity discovered 4/1/15 and recovered 4/2/15. Violations cited against 22H (117-21724) are corrected following remedial efforts. TLT |
2397660 | Primary Facility | 2015-07-15 | Administrative/File Review | No Violations Noted | 7/16/16: DEP reviewed Remedial Action Completion Report, no technical deficiencies were noted. |
2404126 | Primary Facility | 2015-08-25 | Administrative/File Review | No Violations Noted | On March 26, 2015, while conducting a site characterization following the stimulation of the 22H and 24H wells at the Cruttenden 846 well pad, field soil conductivity readings above 1.5 milliSiemens per centimeter were detected. Shell notified the Department of its findings that same day and elected to remediate the area affected area. From 3/2715 through 3/30/15 approximately 282.19 tons of gravel were excavated and disposed of at the Waste Management Landfill. On 8/25/15 the Remedial Action Completion Report was submitted to the DEP and documents the post remediation sample locations, sample results and disposal receipts for the excavated material. The report states that the analytical results of the post-excavation soil samples collected on 3/20/15 exhibited concentrations less that the most stringent Medium Specific Concentrations (MSC). The document will be handled in accordance with the Alternative Remediation provision of the Department policy document 800-5000-001 Addressing Spills and Releases at Oil and Gas Well Sites or Access Roads |
2406740 | Primary Facility | 2015-09-03 | Administrative/File Review | No Violations Noted | 9/3/15 - Approval of Remedial Action Completion Report. |
2509140 | Primary Facility | 2016-08-08 | Routine/Complete Inspection | No Violations Noted | The Department of Environmental Protection inspected the SWEPI LP – Cruttenden 846 well pad in Middlebury Twp., Tioga Co. on 8/8/2016 @1300 hours. The weather was 80° and sunny. An adequate site ID sign was located at the entrance to the access road. An E&S inspection was last conducted by company personnel on 8/2/2016 with “no change” noted in the comments section. A small erosion channel was visible along the south side of the access road. Silt sock was visible along the access road to the tank pad.
Secondary containment around the produced fluid tank contained a small amount of water with a field tested conductivity of ~700µS/cm. A hose connected the produced fluid tank to a battery of temporary tanks, located on containment, on the NE corner of the pad. Two large puddles were observed between the production equipment and the battery of temporary tanks. Puddle 1 had a field conductivity of 4.17 mS/cm. Puddle 2 had a field conductivity of 3.2 mS/cm. Conductivity was tested with an Eutech Instruments O |
2513050 | Primary Facility | 2016-08-19 | Follow-up Inspection | No Violations Noted | The Department of Environmental Protection conducted a follow-up inspection at the SWEPI LP – Cruttenden 846 well pad in Middlebury Twp., Tioga Co. on 8/8/2016 @1230 hours. The weather was 78° and sunny. An adequate site ID sign was located at the entrance to the access road. An E&S inspection was last conducted by company personnel on 8/172016 with “some small erosion channels on access road” noted in the comments section. This issue was also noted in the previous inspection report dated 8/8/2016.
As of today’s inspection approximately 5 puddles were observed on the pad surface in approximately the same locations as noted in the previous inspection. The field conductivities ranged from ~1.9 mS/cm – 2.4 mS/cm. Conductivity was tested with a Eutech Instruments Oakton Multi-Parameter PCSTestr 35. The hose connecting the permanent produced fluid tank to the temporary tank battery was laying in the tank containment. No fluid was observed in the temporary tank containment during today’s inspection. Staining wa |
2543133 | Primary Facility | 2016-12-09 | Routine/Complete Inspection | No Violations Noted | Cruttenden 846 located in Middlebury Twp. Tioga County. Inspected 12/9/16 @ 1040 hours. Weather- light snow, 28 degrees. No violations noted. Departed sit @ 1126 hours. |
2591356 | Primary Facility | 2017-05-08 | Routine/Partial Inspection | No Violations Noted | EC readings with an Oakkton PCSTestr 35: wheelie trailer containment--0.18 & 0.13 mS/cm, production tank containment--1.3 mS/cm, pad--0.33. A pungent odor is emanating from the smoke stack on production equipment. |
2595958 | Primary Facility | 2017-05-18 | Routine/Complete Inspection | No Violations Noted | |
2695125 | Primary Facility | 2018-02-15 | Routine/Partial Inspection | No Violations Noted | I spoke with Wayne Nichols (SWEPI) on site who explained the liner is compiled of a 40 mil plastic sandwiched between 2 layers of felt. SWEPI SET 4 conductor casings for the Utica Shale wells that they plan to drill this March. One of the conductors is larger (20") to accept fiberoptic equipment. Air temp 62F. Inspection log in mailbox near production tank; last inspection listed on February 10, 2018. JLP |
2812036 | Primary Facility | 2018-12-07 | Routine/Complete Inspection | No Violations Noted | Cold/windy at time of inspection |
2813499 | Primary Facility | 2018-12-11 | Routine/Complete Inspection | No Violations Noted | The DEP conducted a routine inspection of SWEPI LP's Cruttenden 846 Well Pad in Middlebury Twp, Tioga County on 12/11/2018 1415 hours. The weather was partly cloudy and 27 degrees.
There are currently 2 actively producing wells onsite with one production tank. The pony pad to the West is being used to store some piping and some farm equipment. A puddle on the pad surface (after ice was broken) had a field measured conductivity of 490us/cm. No erosional issues observed. The cut slope to the East is well vegetated and appears to be stabilized. No violations noted today, I departed the site at 1450. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2332095 | 713196 | 12/30/2014 | 2014-12-30 | 78.12* - Oil or gas well drilled, altered or operated not in accordance with a permit or the regulations. | Administrative | Conservation well encroached on the 330 foot distance restriction |
2335236 | 713889 | 12/30/2014 | 2014-12-30 | 78.12* - Oil or gas well drilled, altered or operated not in accordance with a permit or the regulations. | Administrative | Viols closed 2/4/15; Duplicate record entered in error - see Insp 2332095 and Enf 318683. |
2346183 | 716680 | 02/23/2015 | 2015-02-23 | 78.54 - GENERAL REQUIREMENTS - Operator failed to control and dispose of fluids, residual waste and drill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, and production fluids | Environmental Health & Safety | 78.54. Failure to control and dispose of fluids in accordance with Sections 78.55 - 78.58 and 78.60 - 78.63. Approximately one barrel of production water spilled into containment and subsequently onto the ground. Spill cleanup completed by morning of 2/22/15. TLT |
2346183 | 716681 | 02/23/2015 | 2015-02-23 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | Solid Waste Mgmt Act 6018.301 for causing or allowing an unpermitted discharge of residual waste onto the ground. Approximately one barrel of production water spilled into containment and subsequently onto the ground. Spill cleanup completed by morning of 2/22/15. TLT |
2346183 | 716682 | 02/23/2015 | 2015-02-23 | OGA3218.2(A) - Failure to design and construct unconventional well site to prevent spills to the ground surface and off well site. | Environmental Health & Safety | Oil and Gas Act 3218.2(a)(2) for failure of the containment practice to be sufficiently imperviousand able to containe spilled material. Approximately one barrel of production water spilled into containment and subsequently onto the ground. Spill cleanup completed by morning of 2/22/15. TLT |
2359754 | 719636 | 04/07/2015 | 2015-04-07 | 78.54 - GENERAL REQUIREMENTS - Operator failed to control and dispose of fluids, residual waste and drill cuttings, including tophole water, brines, drilling fluids, drilling muds, stimulation fluids, well servicing fluids, oil, and production fluids | Environmental Health & Safety | 25 Pa Code §78.54 for failing to control and dispose of fluids in accordance with §§78.55 - 78.58 and 78.60 - 78.63. Elevated soil conductivity was discovered on the well pad following removal of the temporary containment. Standing water with elevated conductance found on the pad surface and in r |
2359754 | 719637 | 04/07/2015 | 2015-04-07 | SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. | Environmental Health & Safety | 35 P.S. §6018.301 for causing or allowing an unpermitted discharge of residual waste onto the ground. Elevated soil conductivity was discovered on the well pad following removal of the temporary containment. Standing water with elevated conductance found on the pad surface and in rock-lined ditch. |
2359754 | 719638 | 04/07/2015 | 2015-04-07 | OGA3218.2(A) - Failure to design and construct unconventional well site to prevent spills to the ground surface and off well site. | Environmental Health & Safety | 58 Pa.C.S. §3218.2(a)(2) for failure of the containment practice to be sufficiently impervious and able to contain spilled material. Elevated soil conductivity was discovered on the well pad following removal of the temporary containment. Standing water with elevated conductance found on the pad su |
2359754 | 719639 | 04/07/2015 | 2015-04-07 | CSL 402(b) - POTENTIAL POLLUTION - Conducting an activity regulated by a permit issued pursuant to Section 402 of The Clean Streams Law to prevent the potential of pollution to waters of the Commonwealth without a permit or contrary to a permit issue | Environmental Health & Safety | 35 P.S. §691.402 for the potential to pollute Waters of the Commonwealth. Elevated soil conductivity was discovered on the well pad following removal of the temporary containment. Standing water with elevated conductance found on the pad surface and in rock-lined ditch. |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
713196 | 318683 | NOV - Notice of Violation |
For data sources see[8]