If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21784 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.645403,"lon":-77.290533,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Duncan Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 149047 | |
Farm/Lease Name: PHOENIX 593975 | |
License Status: | |
Spud Date: 2016-12-27 | |
Permit Date: 2015-07-24 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.645403 | |
Longitude: -77.290533 |
Date | Event |
---|---|
Deviated | |
2015-07-24 | New Permit Application |
2016-07-19 | Permit Renewal Application |
2016-12-27 | Performed Spud Operation |
2017-04-30 | Drilling Completion |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2017-10-07 | 2017-10-28 | 7,777 | 11,535,900 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand (Proppant) | FTS International | Proppant | Listed Below | ||||
Hydrochloric Acid (15%) | FTS International | Acidizing | Listed Below | |||||
HVG-1 | FTS International | Gelling Agent | Listed Below | |||||
Nu Flow 1000 | FTS International | Diverting Agent | Water | 7732-18-5 | 45 | 0.0108629 | 12046.5 | |
ABP-1 | FTS International | Breaker | Listed Below | |||||
MX-5-3886 | Multi-Chem | Bacteria Treatment | Listed Below | |||||
FRW-1450 | FTS International | Friction Reducer | Listed Below | |||||
CS-500-SI | FTS International | Scale Inhibitor | Listed Below | |||||
LD-2550 | Multi-Chem | Friction Reducer | Listed Below | |||||
Contains no hazardous substances in concentrations above cut-off values according to the competent authority |
Proprietary | 100 | 0.00494099 | 5479.35 | ||||
Isopropanol | 67-63-0 | 30 | 0.00008940 | 99.139 | ||||
Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.00750696 | 8324.9 | ||||
Petroleum Distillate | 64742-47-8 | 20 | 0.00482794 | 5353.98 | ||||
Inner Salt of Alkyl Amines | Proprietary | 60 | 0.00290019 | 3216.19 | ||||
Dimethylformamide | 68-12-2 | 10 | 0.00002980 | 33.046 | ||||
Inner Salt of Alkyl Amines | Proprietary | 60 | 0.00290019 | 3216.19 | ||||
Hydrochloric Acid | 7647-01-0 | 15 | 0.0241555 | 26787.5 | ||||
Fatty Nitrogen Derived Amides | Proprietary | 5 | 0.00125116 | 1387.48 | ||||
Surfactant | 68439-51-0 | 2 | 0.00002912 | 32.295 | ||||
Clay | 14808-60-7 | 2 | 0.00002912 | 32.295 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000241397 | 267.699 | ||||
Ammonium Chloride | 12125-02-9 | 1 | 0.000241397 | 267.699 | ||||
Fatty Nitrogen Derived Amides | Proprietary | 5 | 0.00125116 | 1387.48 | ||||
Oleic Acid Diethanolamide | 93-83-4 | 2 | 0.000482794 | 535.399 | ||||
Sodium Chloride | 7647-14-5 | 10 | 0.000483365 | 536.031 | ||||
Petroleum Distillate | 64742-47-8 | 55 | 0.000800857 | 888.117 | ||||
Surfactant | 68439-51-0 | 2 | 0.00002912 | 32.295 | ||||
Distillates (Petroleum), Hydrotreated Light | 64742-47-8 | 30 | 0.00621723 | 6894.64 | ||||
Polyactide Resin | 9051-89-2 | 98 | 0.00927899 | 10290 | ||||
Sodium Chloride | 7647-14-5 | 5 | 0.00125116 | 1387.48 | ||||
Calcium Nitrate.4H2O | 13477-34-4 | 100 | 0.0576878 | 63973.4 | ||||
Ethylene Glycol | 107-21-1 | 30 | 0.00008940 | 99.139 | ||||
Alcohols, C12-16, Ethoxylated | 68551-12-2 | 2 | 0.000482794 | 535.399 | ||||
Ammonium Persulfate | 7727-54-0 | 95 | 0.00002998 | 33.25 | ||||
Ethoxylated Alcohol | Proprietary | 5 | 0.00125116 | 1387.48 | ||||
Alcohols, C12-16, Ethoxylated | 68551-12-2 | 2 | 0.000482794 | 535.399 | ||||
Organic Amine Resin Salt | Proprietary | 30 | 0.00008940 | 99.139 | ||||
Sodium Chloride | 7647-14-5 | 10 | 0.000483365 | 536.031 | ||||
Ethylene Glycol | 107-21-1 | 10 | 0.00238669 | 2646.74 | ||||
Clay | 14808-60-7 | 2 | 0.00002912 | 32.295 | ||||
Calcium Nitrate.4H2O | 13477-34-4 | 100 | 0.0576878 | 63973.4 | ||||
Oleic Acid Diethanolamide | 93-83-4 | 2 | 0.000482794 | 535.399 | ||||
Polyacrylate | Proprietary | 30 | 0.00750696 | 8324.9 | ||||
Guar Gum | 9000-30-0 | 50 | 0.000728052 | 807.379 | ||||
Contains no hazardous substances in concentrations above cut-off values according to the competent authority |
Proprietary | 100 | 0.00494099 | 5479.35 | ||||
Aromatic Aldehyde | Proprietary | 10 | 0.00002980 | 33.046 | ||||
Hydrotreated Light Petroleum Distillate | 64742-47-8 | 30 | 0.00750696 | 8324.9 | ||||
Silica Substrate | 14808-60-7 | 100 | 12.8576 | 14,258,600.0 | ||||
Petroleum Distillate | 64742-47-8 | 55 | 0.000800857 | 888.117 | ||||
Quaternary Ammonium Compound | Proprietary | 10 | 0.00002980 | 33.046 | ||||
Copolymer of 2-Propenamide | 69418-26-4 | 30 | 0.00724192 | 8030.98 | ||||
Sodium Chloride | 7647-14-5 | 5 | 0.00125116 | 1387.48 | ||||
Polyactide Resin | 9051-89-2 | 98 | 0.00927899 | 10290 | ||||
Ethoxylated Alcohol | Proprietary | 5 | 0.00125116 | 1387.48 | ||||
Guar Gum | 9000-30-0 | 50 | 0.000728052 | 807.379 | ||||
Alcohols, C11-14-iso-,C13-rich, ethoxylated | 78330-21-9 | 5 | 0.0010362 | 1149.11 | ||||
Polyacrylate | Proprietary | 30 | 0.00750696 | 8324.9 | ||||
Petroleum Distillate | 64742-47-8 | 20 | 0.00482794 | 5353.98 | ||||
CI-150 | FTS International | Acid Corrosion Inhibitor | Listed Below | |||||
Water | FTS International | Carrier/Base Fluid | Water | 7732-18-5 | 100 | 86.8089 | 96,267,300.0 | |
FRW-920 | FTS International | Friction Reducer | Listed Below | |||||
Other Chemical(s) | Listed Above | See Trade Name(s) List | Water | 7732-18-5 | 45 | 0.0108629 | 12046.5 | |
MX-8-4543 | Multi-Chem | Bacteria Treatment | Listed Below | |||||
LD-2250 | Multi-Chem | Friction Reducer | Listed Below |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2016 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 185,352.00 | 42 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 1,129,764.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 762,526.00 | 364 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | EQT PROD CO | Other Oil & Gas Wastes | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid | 19,375.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Drilling Fluid Waste | 1,092.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 430.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 41.02 Tons | LANDFILL | 301358 |
2017 | EQT PROD CO | Produced Fluid | 4,139.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | EQT PROD CO | Drilling Fluid Waste | 3,315.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | EQT PROD CO | Produced Fluid | 5,320.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 88.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2017 | EQT PROD CO | Drill Cuttings | 1,301.13 Tons | LANDFILL | 301358 |
2017 | EQT PROD CO | Drilling Fluid Waste | 851.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 640.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | EQT PROD CO | Produced Fluid | 3,009.19 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | EQT PROD CO | Drill Cuttings | 21.50 Tons | LANDFILL | 100172 |
2018 | EQT PROD CO | Waste Water Treatment Sludge | 14.51 Tons | RESIDUAL WASTE PROCESSING FACILITY | ORDER 2016-29 |
2018 | EQT PROD CO | Produced Fluid | 404.71 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 39.99 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | EQT PROD CO | Soil Contaminated by Oil & Gas Related Spills | 13.65 Tons | LANDFILL | 301358 |
2018 | EQT PROD CO | Produced Fluid | 567.37 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Produced Fluid | 561.21 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Servicing Fluid | 2.57 Tons | LANDFILL | 301358 |
2018 | EQT PROD CO | Produced Fluid | 8,480.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 870.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 36.67 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 1.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Produced Fluid | 2,274.62 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 18.26 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 531.55 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | EQT PROD CO | Soil Contaminated by Oil | 13.65 Tons | LANDFILL | 301358 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 193.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | EQT PROD CO | Produced Fluid | 3,260.40 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EQT PROD CO | Produced Fluid | 136.86 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 15.82 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2019 | EQT PROD CO | Produced Fluid | 425.07 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 12.24 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | EQT PROD CO | Produced Fluid | 674.93 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 163.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | EQT PROD CO | Produced Fluid | 103.89 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 8.73 Tons | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 276.50 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | EQT PROD CO | Produced Fluid | 73.57 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2399603 | Primary Facility | 2015-08-17 | Preoperation Inspection | No Violations Noted | ESCGP was amended. Inspection to document earth work completed following amendment and prior to drilling of new wells. Disturbed areas have been stabilized and E&S controls are installed. TLT |
2485970 | Primary Facility | 2016-05-12 | Routine/Partial Inspection | No Violations Noted | Inspection to resolve outstanding violations against the Phoenix 590627 well. DEP Environmental Cleanup and Brownfield Program has approved the Act 2 final report for attainment of the Statewide Health Standards for soil at the site. As such, the 2/1/12 and 8/2/12 violations against permit #117-20725 (Phoenix 590627) are resolved. No new issues were observed at the site. TLT |
2551778 | Primary Facility | 2017-01-09 | Routine/Partial Inspection | No Violations Noted | Routine partial inspection. Site snow covered. Well pad being prepared for arrival of the drill rig. Five new wells permitted and were reported as spud on 12/27/16. Entire pad surface covered by mats, which were underlain with textured liner. Crew on site working to berm up the liner around the perimeter of the pad. Impoundment 2 was frozen over and snow covered; adequate freeboard remained. Multiple piles of spoil material observed at staging area along access road. Material to be placed for subbase for the above ground storage tank pad, which will be constructed at the former Impoundment 1 location. TLT |
2592186 | Primary Facility | 2017-05-10 | Routine/Complete Inspection | No Violations Noted | I arrived on-site @11:20 hrs and met Bill Wallace of SWN. Patterson/UTI rig 294 on site, running pipe into the 593939 well, and anticipate skidding the rig to the 593940 well tonight. Site was neat, secondary containment was present and in good condition on top of rig mats. Chemical storage and backyard looked good. I departed the site @11:50 hrs. |
2614033 | Primary Facility | 2017-07-06 | Routine/Partial Inspection | No Violations Noted | No activity on the pad when I arrived. 10 K bbl. tank had been erected on the site, approximately 1/2 full of what appeared to be precipitation. Some water had collected in the pad containment near the edges; conductivity of this water was in the .45- .67 mS/cm range. The tank also appeared to have a remote monitoring system hooked up to it. Rig mats were still down over the entire pad from drilling operations. The liner berm at the site entrance seemed somewhat worn; I recommend that it be fully assessed before any fracing operations begin. |
2657516 | Primary Facility | 2017-11-01 | Incident- Response to Accident or Event | No Violations Noted | I met with Corey Giles of EQT and Neil Ketchum of Groundwater Sciences when I arrived. My inspection was in response to a reported release to the drainage ditch on the south side of the pad. A third party EHS group discovered water with elevated conductance (1-3.5 mS/cm) in the ditch on 10/31. The area had been more or less continuously vacced between the time it was discovered and the time I arrived. Corey and Neil had just finished taking soil and water conductance readings along the length of the ditch (see attached photos). Their investigation showed a gradient, beginning on the south side of the pad in the ditch approximately 100-125' east of the pad entrance, with the highest soil and water conductance in that area (6.77 mS/cm water, 2.57 mS/cm soil) and declining readings as they probed downgradient. At the time, the source of the water was unknown, but the area where the water was coming into the ditch seemed to be at the area of highest conductance. The containment berm on the pad had not yet |
2743522 | Primary Facility | 2018-06-19 | Routine/Complete Inspection | No Violations Noted | The DEP inspected the EQT – Phoenix Site C Well Pad located in Duncan Twp, Tioga Co. on 6/20/2018 @1100 hours. The weather was 78 degrees, 45% humidity and winds N 12mph. The receiving waters are listed as Sand Run (CWF) wild trout stream. The well site is in production. No activity was observed onsite during this inspection.
The site consists of the access road, freshwater impoundment, and well pad on a total of 22.4 acres. The impoundment is drawn down and almost empty. There are 11 wells currently in production, and one plugged well. The area surrounding the well pad appeared stabilized. A plastic bag containing old foam berms has blown onto the south slope of the pad and should be removed. No new violations were noted during this inspection. The following violations from Inspection Record #2657056 dated 11/01/2017, resulting from the release of a pollutional substance to the drainage ditch, remain OUTSTANDING against the PHOENIX 590627 Well (API#117-20725): 35 PS § 691.402(b) Potential to pollute |
For data sources see[8]