{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.581542,"lon":-77.101017,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Liberty Township | |
Operator Name: SWN PROD CO LLC | |
Well Pad ID: 152994 | |
Farm/Lease Name: BLISS 5H | |
License Status: | |
Spud Date: | |
Permit Date: 2015-11-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 41.581542 | |
Longitude: -77.101017 |
Date | Event |
---|---|
2015-11-19 | New Permit Application |
2016-11-01 | Permit Renewal Application |
2017-08-15 | Performed Spud Operation |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2018-04-07 | 2018-04-23 | 6,944 | 11,936,400 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | EXCELERATE LX-1 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 |
HYDROCHLORIC ACID | Halliburton | Solvent | Listed Below | Listed Below | 0 | 0 | 0 | |
BE-9W | Halliburton | Biocide | Listed Below | Listed Below | 0 | 0 | 0 | |
SAND-PREMIUM WHITE-30/50, BULK | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 | |
Sodium chloride | 7647-14-5 | 5 | 0.00149892 | 1677 | ||||
Propylene glycol | 57-55-6 | 60 | 0.0251845 | 28161 | ||||
Hydroteated light petroleum distillate | 64742-47-8 | 30 | 0.00899349 | 10057 | ||||
Organic phosphonate | Proprietary | 60 | 0.0151272 | 16915 | ||||
Hydrochloric acid | 7647-01-0 | 15 | 0.110876 | 123980 | ||||
Inorganic salt | Proprietary | 30 | 0.0229605 | 25675 | ||||
Acrylamide acrylate copolymer | Proprietary | 30 | 0.0229605 | 25675 | ||||
Non-hazardous food substance | Proprietary | 100 | 0.000487397 | 545 | ||||
Crystalline silica, quartz | 14808-60-7 | 100 | 10.11 | 11,304,800.0 | ||||
Fatty acid ester | Proprietary | 5 | 0.00299783 | 3354 | ||||
Hydrotreated light petroleum distillate | 64742-47-8 | 30 | 0.0229605 | 25675 | ||||
Tributyl tetradecyl phosphonium chloride | 81741-28-8 | 10 | 0.00419742 | 4694 | ||||
Polyacrylate | Proprietary | 30 | 0.00899349 | 10057 | ||||
Diammonium phosphate | 7783-28-0 | 5 | 0.0012606 | 1410 | ||||
Ethoxyalted fatty acid | Proprietary | 5 | 0.00149892 | 1677 | ||||
Ammonium chloride | 12125-02-9 | 30 | 0.0090625 | 10135 | ||||
HAI-150E | Halliburton | Corrosion Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
Ingredients | Listed Above | Listed Above | Water | 7732-18-5 | 100 | 0.860181 | 961842 | |
LP-65 MC | Halliburton | Scale Inhibitor | Listed Below | Listed Below | 0 | 0 | 0 | |
Fresh Water | Operator | Base Fluid | Water | 7732-18-5 | 100 | 88.9767 | 99,492,300.0 | |
FR-76 | Halliburton | Friction Reducer | Listed Below | Listed Below | 0 | 0 | 0 | |
SAND-COMMON WHITE-100 MESH, SSA-2, BULK (100003676) | Halliburton | Proppant | Listed Below | Listed Below | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | SWN PROD CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2018 | SWN PROD CO LLC | 3,540,515.00 | 230 | 0.00 | 0 | 0.00 | 0 |
2019 | SWN PROD CO LLC | 2,525,092.00 | 319 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW011 |
2017 | SWN PROD CO LLC | Produced Fluid | 338.42 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 393.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 1,815.75 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 420.00 Bbl | REUSE (AT WELL PAD) | |
2017 | SWN PROD CO LLC | Other Oil & Gas Wastes | 55.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Soil Contaminated by Oil | 0.81 Tons | LANDFILL | 301358 |
2017 | SWN PROD CO LLC | Drill Cuttings | 1,567.36 Tons | LANDFILL | 301626 |
2017 | SWN PROD CO LLC | Soil Contaminated by Oil & Gas Related Spills | 0.81 Tons | LANDFILL | 301358 |
2017 | SWN PROD CO LLC | Synthetic Liner Materials | 17.71 Tons | LANDFILL | 101247 |
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 1,035.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2017 | SWN PROD CO LLC | Drilling Fluid Waste | 2,101.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWN PROD CO LLC | Produced Fluid | 16,730.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 160.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 460.00 Bbl | REUSE (AT WELL PAD) | |
2018 | SWN PROD CO LLC | Produced Fluid | 10,006.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 275.42 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Produced Fluid | 11.22 Tons | LANDFILL | 301358 |
2018 | SWN PROD CO LLC | Filter Socks | 0.25 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301333 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2018 | SWN PROD CO LLC | Produced Fluid | 9,845.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 1,102.50 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2018 | SWN PROD CO LLC | Waste Water Treatment Sludge | 11.73 Tons | LANDFILL | 301358 |
2018 | SWN PROD CO LLC | Unused Fracturing Fluid Waste | 61.02 Tons | LANDFILL | 301358 |
2018 | SWN PROD CO LLC | Other Oil & Gas Wastes | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123 |
2019 | SWN PROD CO LLC | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC035 |
2019 | SWN PROD CO LLC | Waste Water Treatment Sludge | 8.48 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2019 | SWN PROD CO LLC | Produced Fluid | 1,470.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 55.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NC010 |
2019 | SWN PROD CO LLC | Other Oil & Gas Wastes | 110.00 Bbl | SURFACE IMPOUNDMENT | 95-16-65420-013 |
2019 | SWN PROD CO LLC | Produced Fluid | 302.50 Bbl | REUSE (AT WELL PAD) | |
2019 | SWN PROD CO LLC | Unused Fracturing Fluid Waste | 14.06 Tons | LANDFILL | 301358 |
2019 | SWN PROD CO LLC | Produced Fluid | 55.00 Bbl | SURFACE IMPOUNDMENT | 826342 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2509256 | Primary Facility | 2016-08-10 | Routine/Complete Inspection | No Violations Noted | This inspection was conducted to assess current site conditions. No Southwestern representatives were present.
Construction of the well site is still underway. The pad area has been cleared of timber, and temporary erosion and sediment control BMPs have been installed along the perimeter of the site. The areas disturbed by access road construction are now vegetated and appear stable. No evidence of accelerated erosion or sedimentation was observed. No violations were cited during this inspection. |
2518671 | Primary Facility | 2016-09-13 | Routine/Complete Inspection | No Violations Noted | nspection of perimeter erosion and sediment control BMPs conducted at the request of Southwestern Energy. Rich Gulyas and Tom Chitwood of Southwestern were present.
Installed perimeter controls consisted of a mulch berm along the entire perimeter, with compost filter socks installed as secondary controls in several locations. The site has been cleared of vegetation, but no major earth disturbance has begun. No evidence of accelerated erosion or sedimenation was observed. Southwestern indicated that construction and major earth disturbance on the well pad portion of the facility (access road already constructed) will commence on after October 1. No violations were cited during this inspection. |
2532064 | Primary Facility | 2016-10-27 | Routine/Complete Inspection | No Violations Noted | Routine inspection to assess overall site conditions and progress of construction. Recent heavy rains (4-6 inches in about 6 hours) occurred one week ago, and it was raining steadily at the time of inspection.
The pad areas has been graded and storm water basins constructed. Stone has not yet been placed on the pad surface. No evidence of accelerated erosion or sedimentation was observed. The perimeter erosion control on this site consists of a contiguous mulch berm with additional berms and filter socks in place at several locations. No sediment was observed to be leaving the limit-of-disturbance for the project. No violations were cited during this inspection. |
2553760 | Primary Facility | 2017-01-20 | Routine/Complete Inspection | No Violations Noted | No wells drilled. No violations ciited during this inspection. |
2575542 | Primary Facility | 2017-03-27 | Routine/Complete Inspection | No Violations Noted | Inspection to assess overall site conditions. Stone has been placed on the entire surface of the well pad. No violations were cited. |
2615222 | Primary Facility | 2017-07-14 | Preoperation Inspection | No Violations Noted | Pre-operational inspection conducted at the request of Southwestern Energy. All perimeter BMPs are installed, and the site has been constructed as designed and permitted. No violations cited. |
2649343 | Primary Facility | 2017-10-18 | Drilling/Alteration | No Violations Noted | At time of inspection they were drilling the 8 3/4 hole. |
2650284 | Primary Facility | 2017-10-20 | Routine/Complete Inspection | No Violations Noted | Inspection to assess site conditions during drilling operations. Most of the site is covered with containment and all equipment, chemicals and materials are being stored within secondary containment. No evidence of spills such as stains or sheens was observed. No violations cited. |
2653612 | Primary Facility | 2017-10-27 | Routine/Complete Inspection | No Violations Noted | I met Jonathan Woodburn on-site. SWN rig # 45 running production casing in the 5H well. Cuttings processing was idle. Containments appeared to be in good condition. The site was somewhat muddy, and Woody told me he had a vac truck scheduled to clean things up. |
2665401 | Primary Facility | 2017-11-30 | Routine/Complete Inspection | No Violations Noted | Inspection to assess site conditions after drilling operations. Preparations for well stimulation are underway. Containment has been placed on the pad surface, and crane mats are stockpiled on site. No issues identified and no violations cited. |
2725508 | Primary Facility | 2018-05-01 | Routine/Complete Inspection | No Violations Noted | I met Joe Forker, SWN company man when I arrived. A workover rig was on the site, and had been drilling out plugs on the 1H well; when I arrived, the rig was tripping out of the well. Joe informed me that they would be deploying fishing tools into the well to recover some live perf guns that were lost in the 8th stage. Joe walked the site with me. A 50-70 gallon puddle on the pad in a high traffic area had slightly elevated conductivity 2.36 mS/cm); all other puddles on the pad were significantly lower (.3- .9 mS/cm). I recommended to Joe that he have it vacced, and while I was still on the site Joe directed a vac truck driver to move to the puddle and clean it up. The containment and berms seemed to be in good condition. |
2773050 | Primary Facility | 2018-09-04 | Site Restoration | No Violations Noted | Site restoration inspection with Sara Metz and Mike Jurbala (DEP). A SWN employee was leaving the site as we arrived and requested that we lock the gate when we were finished.
Two of five permitted wells (Bliss 5H and 1H) have been drilled and stimulated. At the time of the inspection, it appeared that the wells were either still in the process of or had recently finished being flowed back. This inspection was conducted in response to submittal of a post-drilling well site restoration report. The site is stable with vegetative cover exceeding 70%. PCSM has been addressed through installation of a bioretention basin that appears to be functioning as designed. The site has been permitted to remain at full pad size. At this time, due to the presence of the temporary storage tank battery, the associated tank battery secondary containment, and the secondary containment around the wells themselves, the site does not yet meet all of the post-drilling site restoration criteria under 78a.65. I recommend returning t |
2842743 | Primary Facility | 2019-02-21 | Routine/Complete Inspection | No Violations Noted | Weather was 40 degrees and sunny. Met with Southwestern representative Andrew Griffith. Well was in shut in and had its surface discharge manifold equipment removed. Well was covered with an orange steel cage due to drilling activities on location. Well had gas monitoring equipment to detect any presence of combustable gas during drilling activities. Well had one annulus vent (9x5) plumbed to surface and closed in at time of inspection. No violations were noted at time of equipment. |
2845188 | Primary Facility | 2019-02-26 | Routine/Complete Inspection | No Violations Noted | SDC 44 rig on location. I met Andrew Griffith of SWN on the site; rig was running casing in the 4H well, and Andrew told me the rig would be skidding to the 6H well on the evening of 2/26. Sitewide and secondary containments and berms appeared to be in good condition, and the cuttings processing area and backyard were clean and well maintained. Chemical storage areas were clean as well. Andrew informed me that they were using dual-fuel air packs which are capable of diesel and natural gas blended up to 70% diesel. Most of the air packs were not in use while I was on the site. |
2852984 | Primary Facility | 2019-03-13 | Routine/Complete Inspection | No Violations Noted | Weather was 30 degrees and sunny. Met with Southwestern representative Dan Hessdorfer on location. Well was in shut in and had its surface discharge manifold equipment removed. Well was covered with an orange steel cage due to drilling activities on location. Well had gas monitoring equipment to detect any presence of combustable gas during drilling activities. Well had one annulus vent (9x5) plumbed to surface and closed in at time of inspection. No violations were noted at time of equipment. |
For data sources see[8]