If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-117-21870 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.739431,"lon":-76.959856,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Tioga | |
Municipality: Sullivan Township | |
Operator Name: SWEPI LP | |
Well Pad ID: | |
Farm/Lease Name: COTTON HANLON 595 1X | |
License Status: | |
Spud Date: | |
Permit Date: 2016-10-11 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.739431 | |
Longitude: -76.959856 |
Date | Event |
---|---|
2016-10-11 | New Permit Application |
For data sources see[4]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2584475 | Primary Facility | 2017-04-14 | Routine/Partial Inspection | No Violations Noted | Water in basin 0.20 mS/cm Oakton PCSTestr 35 |
2588459 | Primary Facility | 2017-05-01 | Routine/Complete Inspection | No Violations Noted | Well was permitted but never materialized. |
2596464 | Primary Facility | 2017-05-23 | Routine/Complete Inspection | No Violations Noted | I arrived on-site @ 11:30 hrs. and met Brett McCoy, SWEPI company man. Ensign rig 192 on location drilling the 5H well; Mr. McCoy expected to be at TD sometime on Tuesday (currently @ 11460'). The foam berm had gravel added in drive-over areas, and in spots was compressing the berm. Mr. McCoy and I discussed some long-term solutions for this, including adding a hard berm such as a timber in these areas. As it was impossible to tell how high the berm still was, no violation will be issued for insufficient containment, but I recommend that this potential issue be taken into account for the move to the Lingle pad. I departed the site @ 12:20 hrs. |
2629777 | Primary Facility | 2017-08-23 | Routine/Complete Inspection | No Violations Noted | I met Matt Jentsh and Rafael Diaz when I arrived on-site. Frac had ended earlier in the day, and most fracing equipment had already been removed from the site. A sitewide liner was in use with 4" foam berms for containment. On the west side of the pad between the foam berm and the soil berm, I discovered numerous puddles with elevated conductance (see sketch for details). A large volume of water showing elevated conductance (12-18mS/cm) was present in containment at the foam berm immediately next to these puddles. I continued field screening puddles on my way down to the sediment trap, finding puddles of 2.2 and 2.8 mS/cm on my way; conductance readings in the sediment trap were much lower (.595 mS/cm). I then discovered a large puddle (20-25 gallons) on the pad surface off the north side of the containment that showed elevated conductance (4.6-10.2 mS/cm). I informed Matt and Rafael of what I had found, and Matt immediately got a vac truck driver to go to the areas I located on the west side of the p |
2638195 | Primary Facility | 2017-09-21 | Administrative/File Review | No Violations Noted | I received a final analysis from the Departmen's Bureau of Laboratories on 9/21/2017 for sample #0939053, which I took at the Cotton Hanlon pad on 8/23/2017 from a puddle exhibiting elevated conductance. Elevated barium (781.8 mg/l), strontium (533.7 mg/l), and chlorides (11474 mg/l) indicate that a pollutional substance was released to the pad surface. Violations assigned to API # 117-21866. |
For data sources see[5]