37-121-31473

Well Details

Well ID: 37-121-31473
Loading map...
Country: United States
State: Pennsylvania
County: Venango
Municipality: Cornplanter Township
Operator Name: K & M RESOURCES INC
Well Pad ID:
Farm/Lease Name: MCFATE 28Q
License Status: ACTIVE
Spud Date:
Permit Date: 1981-12-22
Well Type: OIL
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.476870
Longitude: -79.626780

For data sources see[1][2][3]

Well History

Date Event
1981-12-22 New Permit Application
1982-03-18 Drilling Completion
1982-03-18 Performed Spud Operation
1983-01-27 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1991 PA GEN ENERGY CORP 0.00 0 39.00 304 0.00 0
1992 RETURN OIL CORP 0.00 0 45.71 360 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
1992 RETURN OIL CORP Brine 4.92 Bbl

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
758823 Primary Facility 1992-02-05 Routine/Complete Inspection Violation(s) Noted
770170 Primary Facility 1996-04-28 Routine/Complete Inspection Violation(s) Noted

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
758823 95994 02/05/1992 1992-02-05 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
758823 95995 02/05/1992 1992-02-05 78.57 - Failure to post pit approval number Administrative
758823 95996 02/05/1992 1992-02-05 206REST - Failure to restore site w/in 9 months of completion of drilling or plugging Environmental Health & Safety
758823 95997 02/05/1992 1992-02-05 301307 - Unpermitted discharge of IW (brine, drill cuttings, & oil spills) Environmental Health & Safety
770170 106954 04/28/1996 1996-04-28 201TAG - Failure to install, in a permanent manner, the permit number on a completed well Administrative
770170 106955 04/28/1996 1996-04-28 301307 - Unpermitted discharge of IW (brine, drill cuttings, & oil spills) Environmental Health & Safety
770170 106956 04/28/1996 1996-04-28 78.56.9101.4 - Impoundment not; permitted or approved, structurally sound, impermeable, third party protected, 2 ft freeboard, inadequate liner, subbase, slopes, capacity, surface water not diverted, w/in 20 inches of high ground water table Administrative

For data sources see[7]