{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.280775,"lon":-79.672647,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Venango | |
Municipality: Richland Township | |
Operator Name: VISTA OPR INC | |
Well Pad ID: | |
Farm/Lease Name: STEPHENS 9 | |
License Status: | |
Spud Date: | |
Permit Date: 2012-09-10 | |
Well Type: OIL | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.280775 | |
Longitude: -79.672647 |
Date | Event |
---|---|
2012-09-10 | New Permit Application |
2012-10-26 | Performed Spud Operation |
2012-10-30 | Drilling Completion |
2015-07-20 | NEWLY DRILLED |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | VISTA OPR INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | VISTA OPR INC | 0.00 | 0 | 374.38 | 365 | 0.00 | 0 |
2014 | VISTA OPR INC | 0.00 | 0 | 239.12 | 365 | 0.00 | 0 |
2015 | VISTA OPR INC | 0.00 | 0 | 137.80 | 365 | 0.00 | 0 |
2016 | VISTA OPR INC | 0.00 | 0 | 21.49 | 365 | 0.00 | 0 |
2017 | VISTA OPR INC | 0.00 | 0 | 48.49 | 120 | 0.00 | 0 |
2018 | VISTA OPR INC | 0.00 | 0 | 88.68 | 214 | 0.00 | 0 |
2019 | VISTA OPR INC | 0.00 | 0 | 74.15 | 153 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2016 | VISTA OPR INC | Produced Fluid | 30.77 Bbl | ROAD SPREADING | |
2018 | VISTA OPR INC | Produced Fluid | 19.07 Bbl | REUSE (AT WELL PAD) | |
2018 | VISTA OPR INC | Produced Fluid | 7.69 Bbl | ROAD SPREADING | |
2018 | VISTA OPR INC | Produced Fluid | 96.83 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2018 | VISTA OPR INC | Produced Fluid | 6.15 Bbl | REUSE AT A CONVENTIONAL WELL SITE IN PA | |
2018 | VISTA OPR INC | Produced Fluid | 6.15 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | 001-A |
2019 | VISTA OPR INC | Produced Fluid | 67.62 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0101508 |
2019 | VISTA OPR INC | Brine Co-Product | 7.69 Bbl | ROAD SPREADING |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2111332 | Primary Facility | 2012-10-29 | Administrative/File Review | No Violations Noted | |
2118480 | Primary Facility | 2012-11-20 | Routine/Complete Inspection | No Violations Noted | |
2135149 | Primary Facility | 2013-01-15 | Routine/Complete Inspection | No Violations Noted | |
2138132 | Primary Facility | 2013-02-12 | Administrative/File Review | No Violations Noted | |
2141137 | Primary Facility | 2013-02-21 | Administrative/File Review | No Violations Noted | |
2205944 | Primary Facility | 2013-09-20 | Site Restoration | No Violations Noted | |
2313524 | Primary Facility | 2014-10-16 | Site Restoration | No Violations Noted | |
2381149 | Primary Facility | 2015-06-23 | Administrative/File Review | No Violations Noted | |
2655995 | Primary Facility | 2017-11-02 | Routine/Partial Inspection | No Violations Noted | Inspection shows well equipped for production with rods, tubing & pump jack powered by a electric motor. Label affixed to the wellhead with the annulus vented to the atmosphere. |