If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-24243 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.16475,"lon":-79.944472,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Carroll Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 145213 | |
Farm/Lease Name: ROBERT SMITH 3H | |
License Status: | |
Spud Date: | |
Permit Date: 2010-07-19 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.164750 | |
Longitude: -79.944472 |
Date | Event |
---|---|
2010-07-19 | New Permit Application |
2010-10-13 | Performed Spud Operation |
2010-11-13 | Drilling Completion |
2011-07-15 | Perforation |
2011-07-15 | Performed Stimulation |
2013-06-06 | DEVIATED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2011-07-12 | 2011-07-12 | 7,627 | 5,965,050 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ACID, HYDROCHLORIC, 15 PCT | Weatherford | Acid | Water | 7732-18-5 | 85.00 | 0.54 | |
Hydrochloric acid | 7647-01-0 | 15.00 | 0.09 | |||||
Inhibitor - WAI-251LC | Weatherford | Corrosion Inhibitor | Isopropanol | 67-63-0 | 7.00 | 0.00002000 | ||
2-Butoxyethanol | 111-76-2 | 5.00 | 0.00001000 | |||||
N,N-Dimethylformamide | 68-12-2 | 30.00 | 0.00008000 | |||||
1-Octanol | 111-87-5 | 7.00 | 0.00002000 | |||||
Proprietary | 13.00 | 0.00003000 | ||||||
1-Decanol | 112-30-1 | 7.00 | 0.00002000 | |||||
Ethylene glycol | 107-21-1 | 40.00 | 0.00011000 | |||||
EC6629 (010) | Nalco | Scale Inhibitor | No Hazardous Components | 0.00 | ||||
WBK-133, Breaker | Weatherford | Breaker | Peroxydisulfuric acid, diammonium salt | 7727-54-0 | 100.00 | 0.00571000 | ||
WFR-61LA | Weatherford | Friction Reducer | Ethoxylated C12-16 alcohols | 68551-12-2 | 7.00 | 0.00796000 | ||
Ammonium chloride | 12125-02-9 | 7.00 | 0.00796000 | |||||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 40.00 | 0.04 | |||||
Sodium chloride | 7647-14-5 | 10.00 | 0.01 | |||||
Fresh Water | Carrier/Base Fluid | 79.65 | ||||||
WGA-15L | Weatherford | Gelling Agent | Proprietary Polymer | 60.00 | 0.01 | |||
Distillates, petroleum, hydrotreated light | 64742-47-8 | 60.00 | 0.01 | |||||
Recycled Produced Water | Carrier/Base Fluid | 9.44 | ||||||
Sand (Proppant) | Proppant | 10.07 | ||||||
WBK-134 | Weatherford | Breaker | Peroxydisulfuric acid, diammonium salt | 7727-54-0 | 100.00 | 0.00482000 | ||
Quartz | 14808-60-7 | 10.00 | 0.00048000 | |||||
Iron Control - WIC-641L | Weatherford | Iron Control Agent | Citric acid | 77-92-9 | 50.00 | 0.00079000 | ||
EC6110A | Nalco | Antibacterial Agent | Glutaraldehyde | 111-30-8 | 60.00 | 0.01 | ||
Ethanol | 64-17-5 | 5.00 | 0.00159000 | |||||
Quaternary Ammonium Compounds | 10.00 | 0.00317000 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2011-07-15 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHESAPEAKE APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | EQT PROD CO | 162,226.00 | 27 | 0.00 | 0 | 0.00 | 0 |
2014 | EQT PROD CO | 1,382,383.00 | 304 | 0.00 | 0 | 0.00 | 0 |
2015 | EQT PROD CO | 944,242.00 | 350 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 564,715.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 380,021.00 | 362 | 0.00 | 0 | 0.00 | 0 |
2018 | EQT PROD CO | 265,965.00 | 361 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 277,776.00 | 289 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2011 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 190.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2011 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 980.00 Bbl | INJECTION DISPOSAL WELL | 34-121-23390 |
2011 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 816.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR119 |
2011 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 300.00 Bbl | INJECTION DISPOSAL WELL | 2D0610317 |
2011 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 9,715.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2011 | CHESAPEAKE APPALACHIA LLC | Fracing Fluid Waste | 605.00 Bbl | INJECTION DISPOSAL WELL | 34-133-21076 |
2012 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 185.00 Bbl | INJECTION DISPOSAL WELL | 34-115-21896 |
2012 | CHESAPEAKE APPALACHIA LLC | Produced Fluid | 210.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Produced Fluid | 605.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Fracing Fluid Waste | 114.00 Bbl | INJECTION DISPOSAL WELL | 34-167-28462 |
2013 | EQT PROD CO | Produced Fluid | 740.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2013 | EQT PROD CO | Drilling Fluid Waste | 115.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Fracing Fluid Waste | 1,350.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | EQT PROD CO | Fracing Fluid Waste | 130.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2013 | EQT PROD CO | Produced Fluid | 740.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2013 | EQT PROD CO | Fracing Fluid Waste | 130.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2014 | EQT PROD CO | Produced Fluid | 3,579.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Fracing Fluid Waste | 740.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Drilling Fluid Waste | 1,563.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | EQT PROD CO | Drilling Fluid Waste | 100.00 Bbl | LANDFILL | SWF 1032-WV0109 |
2015 | EQT PROD CO | Drilling Fluid Waste | 110.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Fracing Fluid Waste | 220.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Produced Fluid | 70.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015 | EQT PROD CO | Produced Fluid | 220.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2015 | EQT PROD CO | Produced Fluid | 1,210.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2015 | EQT PROD CO | Produced Fluid | 8,451.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Other Oil & Gas Wastes | 186.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 10,010.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | EQT PROD CO | Produced Fluid | 358.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 940.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | EQT PROD CO | Produced Fluid | 168.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW005 |
2017 | EQT PROD CO | Produced Fluid | 2.74 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 320.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Produced Fluid | 1,660.04 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 192.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 207.19 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 15.37 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 10.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 10.45 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2018 | EQT PROD CO | Produced Fluid | 12.25 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | EQT PROD CO | Produced Fluid | 111.67 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 174.99 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 91.36 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | EQT PROD CO | Produced Fluid | 120.70 Bbl | REUSE (AT WELL PAD) | |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 10.45 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | EQT PROD CO | Produced Fluid | 5.90 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2019 | EQT PROD CO | Produced Fluid | 8.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2019 | EQT PROD CO | Produced Fluid | 207.19 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 4.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | EQT PROD CO | Produced Fluid | 10.16 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Produced Fluid | 0.61 Bbl | INJECTION DISPOSAL WELL | 34-167-28462 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 24.41 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 247.95 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Produced Fluid | 2.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | EQT PROD CO | Produced Fluid | 6.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1922446 | Primary Facility | 2010-09-01 | Routine/Complete Inspection | No Violations Noted | |
1934201 | Primary Facility | 2010-10-14 | Drilling/Alteration | No Violations Noted | Randsom auger - Well spud, Nomak 243 rigging up to begin drilling operation, closed loop, site and location good. |
1934222 | Primary Facility | 2010-10-20 | Drilling/Alteration | No Violations Noted | Nomak 243 - Rigging up, putting BHA together, site and location good, closed loop |
1934223 | Primary Facility | 2010-10-27 | Drilling/Alteration | No Violations Noted | Nomak 243 - TD@1280,drilling ahead, no return on cement, , grouted back side. Site and location good, closed loop |
1934224 | Primary Facility | 2010-11-09 | Drilling/Alteration | No Violations Noted | Nomak 243 - TD@9031, tripping outto change gamma tool, returns on 9.58, Site and location good, closed loop |
2078352 | Primary Facility | 2012-06-18 | Routine/Complete Inspection | No Violations Noted | |
2350214 | Primary Facility | 2015-03-10 | Routine/Complete Inspection | No Violations Noted | |
2402143 | Primary Facility | 2015-08-14 | Compliance Evaluation | No Violations Noted | On 8/14/15, I inspected the Robert Smith site as a compliance evaluation inspection in response to the remediation report for a spill occurring on 1/31/15 and made the following observations: |
2544063 | Primary Facility | 2016-09-14 | Incident- Response to Accident or Event | No Violations Noted | On 9/14/16 I performed an incident response inspection at the Robert Smith Site in response to an operator reported spill (CTS ID: 322335) and made the following observations:
•On 9/6/16 EQT Corey Giles reported a spill of 100 gallons of produced fluids to the well pad. The spill was forwarded to the WQS on 9/14/16. This constitutes a violation of 25 Pa. Code § 78.57(a) and 25 Pa. Code § 78.54 for failing to control brine and other fluids resulting in discharge to the ground and failure to prevent pollution to the Waters of the Commonwealth. •The spill was cleaned up at the time of inspection with the only observed indicator of the spill location being an area of new gravel on the pad near the production units. No violation. •Well drilling was ongoing at the time of inspection. •During general pad inspection it was noted that multiple production tanks had orange streaking running down their sides from the top of the tanks. The gravel of the pad surface near the containment displayed matching orange stai |
2614133 | Primary Facility | 2017-05-05 | Incident- Response to Accident or Event | In Compliance with Policy | On 5/5/17 an INCDT inspection of the R. Smith well site was conducted in response to CTS ID: 326715. The following was observed:
>> Site was undergoing fracking at time of inspection. >>The spill in question involved roughly 10 gallons of produced water being sprayed from from an overfilled accessory tank on the pad. Affected pad materials were collected and placed in a waste box on pad for disposal. No violation, site appears to be in compliance with policy. >>Streaking was again noted on the outside of multiple production tanks similar to streaking noted in previous inspections. |
2660103 | Primary Facility | 2017-11-09 | Routine/Complete Inspection | No Violations Noted | On 11/10/17 a routine complete inspection of the R. Smith well site was conducted in response to notification additional drilling on site. The following was observed:
>>A box tank was found near the impoundment with no containment. Remediation recommended, no violation. >>A new top soil stock pile was noted on site. It was stabilized with straw at the time of inspection. >>The soil stock pile was noted to not have any functional controls below it other than an adequate vegetated strip. Decomposed CFS should be removed, repaired, or replaced. No violation. >>Drilling was ongoing at the site at the time of inspection. |
2691667 | Primary Facility | 2018-02-02 | Routine/Complete Inspection | No Violations Noted | Well has been fracked and is producing. |
2705383 | Primary Facility | 2018-03-13 | Routine/Partial Inspection | No Violations Noted | On 3/14/18 a routine complete inspection of the R. Smith Well Site was conducted in response to a notification of proposed construction activity on the pad. The following was observed:
>>The site was in a high activity phase at the time of inspection drilling appeared to be completed and the site was in apparent transition to post drilling activities. No drilling rig was present on site at the time of inspection. >>Construction of a proposed AST had not begun at the time of inspection. >>Many water trucks were present on site in association with the attached impoundment. |
2730981 | Primary Facility | 2018-05-16 | Incident- Response to Accident or Event | No Violations Noted | On 5/16/18 an incident inspection of the R. Smith well site was conducted in response to a spill reported by the operator on 5/14/18. The following was observed:
>>The operator reported that roughly 35 gallons of mixed rain water and produced water was spilled to the pad when a section of containment was moved without being drained first. Fluids were spread over a large area of the pad along the area in front of the production units per discussion with Mike Cromley at the time of inspection. This does constitute a violation of 25 Pa. Code § 78.54 and 25 Pa. Code § 78.57(a) in that the operator failed to control regulated materials in a manner that prevents prevents pollution to the ground or Waters of the Commonwealth however, the violation is regarded as immediately corrected. >>Site inspection found no residual evidence of the spill. The operator reported that all visibly impacted gravel from the spill area had been removed (roughly two clamshell dumpsters). |
2747124 | Primary Facility | 2018-06-29 | Routine/Partial Inspection | No Violations Noted | On 6/29/18 a routine partial inspection of the R. Smith Well Site was conducted in response to concerns about runoff raised by a nearby resident. The following was observed:
>>An unstabilized soil pile near the corner of the pad with a newly improved drain. Controls below the pile were absent though the vegetation was sufficient. No violation, remediation recommended. >>Another only partially stabilized soil pile with no controls below the pile was located along the accessory pad access road. No controls beyond vegetation were present below the soil pile. No violation, monitoring recommended. >>An AST was present on the accessory pad. >>The pad was active at the time of inspection with drilling preparations ongoing. A sound wall was present around the pad perimeter. |
2761313 | Primary Facility | 2018-08-02 | Routine/Complete Inspection | No Violations Noted | On 8/2/18 a complaint response inspection was conducted of the R Smith well site in response to reported concerns of inappropriate drainage from the pad. WQSS John Carson accompanied. The following was observed:
>>A top soil pile on the access road to the accessory pad remained lacking vegetation and with spotty temporary stabilization. The vegetative strip below remains in good condition. Remediation recommended, no violation. >>Emptying partially filled containment is encouraged to aid in identifying any possible leaks. No violation. >>No evidence of excessive or unpermitted runoff from the pad was found. >>Box in containment appears to be collecting emergency blowdown. If so it should be properly marked. No violation. |
For data sources see[9]