If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-24461 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.028517,"lon":-80.047392,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Deemston Borough | |
Operator Name: CHEVRON APPALACHIA LLC | |
Well Pad ID: 148738 | |
Farm/Lease Name: LATKANICH UNIT 1H | |
License Status: | |
Spud Date: | |
Permit Date: 2011-06-29 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.028517 | |
Longitude: -80.047392 |
Date | Event |
---|---|
2011-06-29 | New Permit Application |
2011-09-14 | Performed Spud Operation |
2012-01-18 | Drilling Completion |
2012-11-07 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2012-07-11 | 2012-07-11 | 5,882 | 3,043,321 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Clean Volume (gals) | Carrier/Base Fluid | 90.95 | 100.00 | ||||
WG-36 GELLING AGENT | Halliburton Energy Services | Water Viscosifier | Guar gum | 9000-30-0 | 100.00 | 0.00292000 | ||
7.5 Hcl Acid | Used to open perfs | Hydrochloric acid | 7647-01-0 | 7.50 | 0.28 | |||
GBW-30 BREAKER | Halliburton Energy Services | Gel Breaker | Carbohydrates | 95.00 | 0.00009000 | |||
Hemicellulase enzyme | 9012-54-8 | 15.00 | 0.00001000 | |||||
Biocide EC 6116A | Nalco | Biocide | Polyethylene glycol | 25322-68-3 | 60.00 | 0.01 | ||
Dibromoacetonitrile | 3252-43-5 | 5.00 | 0.00124000 | |||||
2,2-Dibromo-3-nitrilopropionamide | 10222-01-2 | 30.00 | 0.00744000 | |||||
FR-66 Friction Reducer | Halliburton Energy Services | Friction Reducer | Distillates, petroleum, hydrotreated light | 64742-47-8 | 30.00 | 0.03 | ||
EC6673W | Nalco | Iron Control | Ethylene glycol | 107-21-1 | 30.00 | 0.00690000 | ||
Proppant (lbs) | Proppant | 9.05 | 10.03 | |||||
ASP 900 | Nalco | Friction Reducer | Ammonium sulfate | 7783-20-2 | 30.00 | |||
EC6486A | Nalco | Scale Inhibitor | Ethylene glycol | 107-21-1 | 30.00 | 0.00736000 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | CHEVRON APPALACHIA LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | CHEVRON APPALACHIA LLC | 126,964.00 | 92 | 0.00 | 0 | 0.00 | 0 |
2013 | CHEVRON APPALACHIA LLC | 503,690.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | CHEVRON APPALACHIA LLC | 377,560.00 | 334 | 0.00 | 0 | 0.00 | 0 |
2015 | CHEVRON APPALACHIA LLC | 279,740.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | CHEVRON APPALACHIA LLC | 203,346.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | CHEVRON APPALACHIA LLC | 185,130.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | CHEVRON APPALACHIA LLC | 160,082.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | CHEVRON APPALACHIA LLC | 143,736.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,230.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Drill Cuttings | 6.09 Tons | LANDFILL | 100419 |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 5,580.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2012 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 15,075.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2012 | CHEVRON APPALACHIA LLC | Drilling Fluid Waste | 13,705.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2013 | CHEVRON APPALACHIA LLC | Fracturing Fluid Waste | 161.28 Tons | LANDFILL | 073 114 654 |
2013 | CHEVRON APPALACHIA LLC | Produced Fluid | 4,844.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 15,440.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CHEVRON APPALACHIA LLC | Fracing Fluid Waste | 200.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW001 |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 1,541.50 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CHEVRON APPALACHIA LLC | Produced Fluid | 66.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW001 |
2015 | CHEVRON APPALACHIA LLC | Produced Fluid | 954.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 133.01 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | CHEVRON APPALACHIA LLC | Produced Fluid | 707.51 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 170.32 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 50.00 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | CHEVRON APPALACHIA LLC | Produced Fluid | 2,755.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 160.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 56.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | CHEVRON APPALACHIA LLC | Other Oil & Gas Wastes | 12.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 327.50 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CHEVRON APPALACHIA LLC | Produced Fluid | 29.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 50.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CHEVRON APPALACHIA LLC | Produced Fluid | 505.33 Bbl | REUSE (AT WELL PAD) |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2004385 | Primary Facility | 2011-09-21 | Drilling/Alteration | No Violations Noted | Well spud, site and location under construction, E&S in place |
2038733 | Primary Facility | 2012-01-05 | Complaint Inspection | No Violations Noted | |
2128295 | Primary Facility | 2012-12-14 | Complaint Inspection | Violation(s) Noted | Pumping pit water to a non-vegetated area is a violation |
2153304 | Primary Facility | 2013-01-09 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On January 9, 2013 I stopped at he Latkanich site to check Chevron's progress at addressing the issues foud during my December 214, 2012 inspection. The pits were mostly filled in. I'll recheck the site later. |
2153306 | Primary Facility | 2013-03-09 | Compliance Evaluation | No Violations Noted | On March 9, 2013 I stopped at he Latkanich site to check Chevron's progress at addressing the issues foud during my December 214, 2012 inspection. The pit was filled in and I found no other violations. |
2582953 | Primary Facility | 2017-02-22 | Complaint Inspection | No Violations Noted | On 2/22/17, a complaint inspection was performed related to the Latkanich site in response to complaint 325171 and made the following observations:
•The complainant requested testing for radiological compounds as reportedly recommended to them by the Isaac Walton League. •The complainant reported suspected past improper disposal of fluids in former ponds on site. Previous inspections of site found no surface indications of spills or contamination. •Samples for 946 and bacteriological analysis were obtained from the tap before the complainants holding tank before any filtration after a 10 minute flush of the system. The sample appeared clear and no smell was noted (possibly due to strong odors present in basement). •The well bore is located roughly 20 feet from the house and has a secure cap elevated 6” off of the ground at the time of inspection. The complainant reported that the well was drilled to 275 feet deep in 1999 and has a poly case to 70 feet. |
2585316 | Primary Facility | 2017-04-20 | Administrative/File Review | No Violations Noted | On 4/20/17, an ADMIN inspection was conducted assisted by WQS Supervisor John Carson regarding the Latkanich site in response to complaint 325171 and made the following observations:
•Results from operator predrill samples taken 8/2/11 and post drill samples from 3/26/13 and 4/8/13 were analyzed in comparison to DEP samples obtained during inspection 2582952 on 2/22/17. Increases in levels of multiple parameters were noted but no conclusive indicators of oil and gas impact were observed. |
2660489 | Primary Facility | 2017-11-08 | Follow-up Inspection | No Violations Noted | On 11/8/17 an FUI inspection was conducted of the Latkanich well site in response to a complaint (CTS ID: 325171) accompanied by WQSS John Carson and DEP Dave McDermott. The following was observed:
>>Labeling on the production tanks was noted to be weathered and difficult to read. >>Containment around a container labeled residual waste was found to be partially compromised and unlikely to hold sufficient liquids in the case of a spill or leak. Further information concerning the contents and providence of the tank have been requested from the operator. >>Production equipment on site was noted to have developed substantial rust. Protection from further weathering and potential failure is encouraged. >>The complainant reported ongoing concerns of impact to well water quality and damage to the home. Sample 3401-068 was collected for 946 and bacteriological analysis. |
2774930 | Primary Facility | 2018-09-05 | Administrative/File Review | No Violations Noted | On 9/5/18 an administrative inspection of the Latkanich Unit Well site conducted with Group Manager Dave McDermott and WQSS John Carson in response to ongoing investigations into site conditions. The following was found:
>>Multiple areas of the site including sections of the entrance, access road and pad were found to have been constructed contrary to permitted plans. This constitutes a violation of 25 Pa. Code § 78.53, 25 Pa. Code § 102.5(c), and 25 Pa. Code § 102.5(m)(4) in that the operator failed to construct to comply with permit conditions in constructing the site and failed to acquire required permits or permit modifications to alter the site from permitted plans. |
2780145 | Primary Facility | 2018-09-26 | Administrative/File Review | No Violations Noted | On 9/26/18 an administrative of the Latkanich Well Site was conducted to correct filing errors related to the below inspection:
Inspection ID: 2771088 On 9/5/18 an administrative inspection of the Latkanich Unit Well site conducted with Group Manager Dave McDermott and WQSS John Carson in response to ongoing investigations into site conditions. The following was found: >>Multiple areas of the site including sections of the entrance, access road and pad were found to have been constructed contrary to permitted plans. This constitutes a violation of 25 Pa. Code § 78.53, 25 Pa. Code § 102.5(c), and 25 Pa. Code § 102.5(m)(4) in that the operator failed to construct to comply with permit conditions in constructing the site and failed to acquire required permits or permit modifications to alter the site from permitted plans. |
2807705 | Primary Facility | 2018-10-30 | Complaint Inspection | No Violations Noted | On 10/30/18 a complaint inspection related to the Latkanich Unit was conducted in response to a water supply complaint (CTS ID: 332897). Water samples were collected for 946 and radiological compound testing (the latter were sent to a third party lab for analysis). |
2853256 | Primary Facility | 2019-03-13 | Complaint Inspection | No Violations Noted | On 3/13/19 a complaint inspection related to the Latkanich Well Site was conducted in response to complaint 332897, the following was observed:
>>Water samples were collected for standard chemical and biological analysis. >>Survey of complainant's property found no evidence of surface impact or spill near well cap. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2128295 | 657164 | 12/14/2012 | 2012-12-14 | 401CSL - Discharge of pollultional material to waters of Commonwealth. | Environmental Health & Safety | |
2128295 | 657165 | 12/14/2012 | 2012-12-14 | 78.60B - Tophole water discharged improperly | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
657164 | 292311 | NOV - Notice of Violation | Comply/Closed | 2013-04-04 | |||
657165 | 292311 | NOV - Notice of Violation | Comply/Closed | 2013-04-04 |
For data sources see[8]