Well ID: 37-125-24713 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.0966,"lon":-80.290467,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: South Franklin Township | |
Operator Name: HG ENERGY II APPALACHIA LLC | |
Well Pad ID: 148019 | |
Farm/Lease Name: CONSOL NV42BHS | |
License Status: | |
Spud Date: | |
Permit Date: 2012-03-22 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.0966 | |
Longitude: -80.290467 |
Date | Event |
---|---|
2012-03-22 | New Permit Application |
2012-04-05 | Performed Spud Operation |
2012-05-19 | Drilling Completion |
2012-09-29 | Drilling Completion |
2013-01-26 | Perforation |
2013-02-17 | Performed Stimulation |
2013-12-04 | DEVIATED |
2014-03-21 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-02-17 | 2013-03-03 | 7,245 | 3,141,470 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | ||||||||
Sand (Proppant), DAP-903, DWP-111, DWP-603, DWP-690, DWP-901, BioClear 2000, Spearhead Acid |
CWS | Propping Agent, Scale Inhibitor, Gel Slurry, Friction Reducer, Breaker, Breaker, Biocide, Clean Perforations | Poly(Acrylamide and Adam methyl Chloride) | 69418-26-4 | 40 | 0.04118 | 11365.9 | |
Poly(oxyethylene)nonylphenol ether | 9016-45-9 | 5 | 0.00588 | 1623.7 | ||||
Direct red 81 | 2610-11-9 | 0.1 | 0.00001000 | 2.68 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0.00011 | 31.73 | ||||
Hydrochloric acid | 7647-01-0 | 35 | 0.40234 | 111061 | ||||
Organic solvent | 57-55-6 | 0.1 | 0.00001000 | 0.27 | ||||
Ammonium chloride | 12125-02-9 | 1.5 | 0.00176 | 487.11 | ||||
Methanol | 67-56-1 | 0.1 | 0.00345 | 951.95 | ||||
Distillates (petroleum), hydrotreated middle | 64742-46-7 | 60 | 0.08382 | 23138 | ||||
Phosphoric acid | 7664-38-2 | 0.1 | 0.00001000 | 0.27 | ||||
Propargyl Alcohol | 107-19-7 | 0.1 | 0.00057 | 158.66 | ||||
Crystalline silica (Quartz) | 14808-60-7 | 100 | 4.28858 | 1,183,800.0 | ||||
Hydrogen Peroxide | 7722-84-1 | 10 | 0.00078 | 214.41 | ||||
Ammonium Persulfate | 7727-54-0 | 100 | 0.00314 | 867 | ||||
2-Propenoic acid, polymer with sodium phosphonate | 71050-62-9 | 60 | 0.00791 | 2183.43 | ||||
Alkenes, C>10 a- | 64743-02-8 | 0.1 | 0.00172 | 475.97 | ||||
Calcite | 471-34-1 | 1 | 0.00901 | 2487.91 | ||||
Sodium chloride | 7647-14-5 | 0.1 | 0.00006000 | 15.87 | ||||
Goethite | 1310-14-1 | 0.1 | 0.00129 | 355.42 | ||||
Modified thiourea polymer | 68527-49-1 | 0.1 | 0.00172 | 475.97 | ||||
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite |
68953-58-2 | 5 | 0.00699 | 1928.17 | ||||
Biotite | 1302-27-8 | 0.1 | 0.00043 | 118.47 | ||||
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether | 37251-67-5 | 1.5 | 0.0021 | 578.45 | ||||
Paraffinic hydrocarbon solvent | 64742-47-8 | 30 | 0.03118 | 8605.6 | ||||
Fatty acids, tall-oil | 61790-12-3 | 0.1 | 0.00172 | 475.97 | ||||
Guar gum | 9000-30-0 | 60 | 0.08382 | 23138 | ||||
Polyethylene glycol mixture | 25322-68-3 | 70 | 0.01446 | 3991.86 | ||||
2,2-Dibromo-3-Nitrilopropionamide | 10222-01-2 | 20 | 0.01446 | 3991.86 | ||||
Sorbitan monooleate | 1338-43-8 | 5 | 0.00588 | 1623.7 | ||||
Alcohols, C14-15, ethoxylated | 68951-67-7 | 0.1 | 0.00172 | 475.97 | ||||
Apatite | 64476-38-6 | 0.1 | 0.00043 | 118.47 | ||||
Water | Customer & CWS | Base Fluid & Mix Water | Water | 7732-18-5 | 100 | 94.9835 | 26,218,900.0 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2013-02-17 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2012 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | CNX GAS CO LLC | 381,268.76 | 269 | 0.00 | 0 | 0.00 | 0 |
2014 | CNX GAS CO LLC | 639,962.36 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 563,377.50 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | NOBLE ENERGY INC | 378,136.59 | 366 | 0.00 | 0 | 0.00 | 0 |
2017 | HG ENERGY II APPALACHIA LLC | 202,580.16 | 337 | 0.00 | 0 | 0.00 | 0 |
2018 | HG ENERGY II APPALACHIA LLC | 226,107.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | HG ENERGY II APPALACHIA LLC | 204,998.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | CNX GAS CO LLC | Drill Cuttings | 140.75 Tons | LANDFILL | 100592 |
2012 | CNX GAS CO LLC | Drill Cuttings | 1,043.67 Tons | LANDFILL | 100172 |
2012 | CNX GAS CO LLC | Drilling Fluid Waste | 767.38 Bbl | LANDFILL | 0250050885 |
2012 | CNX GAS CO LLC | Drill Cuttings | 1.40 Tons | LANDFILL | 0250050885 |
2013 | CNX GAS CO LLC | Produced Fluid | 5,068.42 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | CNX GAS CO LLC | Produced Fluid | 44.69 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2013 | CNX GAS CO LLC | Produced Fluid | 31.78 Bbl | INJECTION DISPOSAL WELL | 34-031-27177 |
2013 | CNX GAS CO LLC | Produced Fluid | 17.42 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2013 | CNX GAS CO LLC | Produced Fluid | 1.65 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2013 | CNX GAS CO LLC | Produced Fluid | 124.41 Bbl | INJECTION DISPOSAL WELL | 34-105-23619 |
2014 | CNX GAS CO LLC | Produced Fluid | 45.18 Bbl | INJECTION DISPOSAL WELL | 34-059-24202 |
2014 | CNX GAS CO LLC | Produced Fluid | 14.27 Bbl | INJECTION DISPOSAL WELL | 34-121-23995 |
2014 | CNX GAS CO LLC | Produced Fluid | 99.86 Bbl | STORAGE PENDING DISPOSAL OR REUSE | |
2014 | CNX GAS CO LLC | Produced Fluid | 54.69 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2014 | CNX GAS CO LLC | Produced Fluid | 11.89 Bbl | INJECTION DISPOSAL WELL | 34-119-28776 |
2014 | CNX GAS CO LLC | Produced Fluid | 11.89 Bbl | INJECTION DISPOSAL WELL | 2D0859721 |
2014 | CNX GAS CO LLC | Produced Fluid | 1,940.03 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CNX GAS CO LLC | Produced Fluid | 1,834.42 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 18.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2016 | CNX GAS CO LLC | Produced Fluid | 54.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2016 | CNX GAS CO LLC | Produced Fluid | 1,274.75 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | NOBLE ENERGY INC | Produced Fluid | 215.83 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | NOBLE ENERGY INC | Produced Fluid | 78.16 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | NOBLE ENERGY INC | Produced Fluid | 256.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018 | HG ENERGY II APPALACHIA LLC | Produced Fluid | 416.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | HG ENERGY II APPALACHIA LLC | Produced Fluid | 265.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2019 | HG ENERGY II APPALACHIA LLC | Produced Fluid | 108.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | HG ENERGY II APPALACHIA LLC | Produced Fluid | 222.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | HG ENERGY II APPALACHIA LLC | Produced Fluid | 314.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2019 | HG ENERGY II APPALACHIA LLC | Produced Fluid | 14.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2112737 | Primary Facility | 2012-10-23 | Drilling/Alteration | No Violations Noted | |
2148827 | Primary Facility | 2013-02-21 | Routine/Complete Inspection | No Violations Noted | |
2163112 | Primary Facility | 2013-03-29 | Routine/Complete Inspection | No Violations Noted | |
2738324 | Primary Facility | 2018-05-16 | Routine/Complete Inspection | No Violations Noted | On May 16, 2018, the Department performed an inspection of the HG Energy, NV42HS well site. Present at time of inspection was Jared Stemple and Jay Kendra (HG). The site is located in South Franklin Twp., Washington Co. The inspection was related to a request by the operator to meet on site to discuss a slid which has developed on the site along the access road and start of construction of the PCSM structures.
The operator plans to re stabilize the fill slope along the access road which recently failed. After the slide repair the operator plans to begin installation of the PCSM structures on the site and progress termination of the ESCGP2 permit. 5 wells have been drilled to completion on the site and are equipped for production. |
2801412 | Primary Facility | 2018-11-08 | Routine/Complete Inspection | No Violations Noted | On 11/8/2018 at approximately 1200, I conducted a Compliance Evaluation Inspection of the NV42HS well site located in South Franklin Township, Washington County. A file review was conducted by John Carson and David McDermott (DEP) on 11/8/2018 regarding a spill of drilling based mud to the graveled well pad. It was determined during the review that a Compliance Evaluation Inspection was required in order to close out the incident. The following was observed during the 11/8/2018 inspection:
|
For data sources see[9]