{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.066272,"lon":-80.380308,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: East Finley Township | |
Operator Name: CNX GAS CO LLC | |
Well Pad ID: 147668 | |
Farm/Lease Name: BEDILLION NV61CHS | |
License Status: | |
Spud Date: | |
Permit Date: 2014-01-17 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.066272 | |
Longitude: -80.380308 |
Date | Event |
---|---|
2014-01-17 | New Permit Application |
2014-03-27 | New Permit Application |
2014-04-05 | Performed Spud Operation |
2014-07-23 | Drilling Completion |
2015-01-04 | Drilling Completion |
2015-05-11 | Perforation |
2015-06-13 | Performed Stimulation |
2016-06-03 | DEVIATED |
2016-06-03 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2015-06-13 | 2015-11-19 | 7,184 | 13,848,600 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Sand (Proppant), DWP-111, DWP-901, Spearhead Acid | CWS | Propping Agent, Gel Slurry, Breaker, Clean Perforations | Calcite | 471-34-1 | 1 | 0.0124462 | 12229.5 |
Ammonium Persulfate | 7727-54-0 | 100 | 0.000299429 | 293 | ||||
Alkenes, C>10 a- | 64743-02-8 | 0.1 | 0.00154705 | 1523.12 | ||||
Ilmenite | 98072-94-7 | 0.1 | 0.00291444 | 2862 | ||||
Methanol | 67-56-1 | 0.1 | 0.00310408 | 3046.24 | ||||
Goethite | 1310-14-1 | 0.1 | 0.00469105 | 4609.06 | ||||
Quaternary ammonium compounds, bis(hydrogenated tallow alkyl)dimethyl, salts with bentonite |
68953-58-2 | 5 | 0.00116777 | 1143.19 | ||||
Biotite | 1302-27-8 | 0.1 | 0.00350331 | 3444.35 | ||||
Hydrochloric acid | 7647-01-0 | 35 | 0.36181 | 355394 | ||||
Apatite | 64476-38-6 | 0.1 | 0.00350331 | 3444.35 | ||||
Propargyl Alcohol | 107-19-7 | 0.1 | 0.00051901 | 507.71 | ||||
Alcohols, C14-15, ethoxylated | 68951-67-7 | 0.1 | 0.00154705 | 1523.12 | ||||
Formaldehyde | 50-00-0 | 0.1 | 0.00009981 | 101.54 | ||||
Fatty acids, tall-oil | 61790-12-3 | 0.1 | 0.00154705 | 1523.12 | ||||
Distillates (petroleum), hydrotreated middle | 64742-46-7 | 60 | 0.0139634 | 13718.2 | ||||
Illite | 12173-60-3 | 1 | 0.00786499 | 7727.4 | ||||
Oxirane, 2-methyl-, polymer with oxirane, monodecyl ether | 37251-67-5 | 1.5 | 0.000349333 | 342.96 | ||||
Crystalline silica (Quartz) | 14808-60-7 | 100 | 8.80008 | 8,644,100.0 | ||||
Modified thiourea polymer | 68527-49-1 | 0.1 | 0.00154705 | 1523.12 | ||||
Guar gum | 9000-30-0 | 60 | 0.0139634 | 13718.2 | ||||
Sodium chloride | 7647-14-5 | 0.1 | 0.00004990 | 50.77 | ||||
ES-FR 170 | KWS | Friction Reducer | Ammonium Chloride | 12125-02-9 | 15 | 0.00319177 | 3135.2 | |
Petroleum Distillate, hydro-treating light | 64742-47-8 | 30 | 0.00638355 | 6270.4 | ||||
Ammonium Acrylate | 10604-69-0 | 0.5 | 0.000106386 | 104.5 | ||||
Sorbitan Monooleate | 1338-43-8 | 3 | 0.000638314 | 627 | ||||
Proprietary Surfactant | Proprietary | 10 | 0.00212782 | 2090.1 | ||||
2-Propenoic acid, ammonium salt, polymer with 2-propenamide, |
26100-47-0 | 25 | 0.00531959 | 5225.3 | ||||
Acrylamide | 79-06-1 | 0.01 | 0.00000214 | 2.1 | ||||
Water | 7732-18-5 | 49 | 0.0104265 | 10241.7 | ||||
ES-SC 190S | KWS | Scale Inhibitor | Water | 7732-18-5 | 60 | 0.0134702 | 13231.4 | |
Polyacrylic acid | 9003-01-4 | 15 | 0.00336759 | 3307.9 | ||||
2-Phosphonobutane-1,2,4-tricarboxylic acid, Potassium salt | 93858-78-7 | 15 | 0.00336759 | 3307.9 | ||||
Sodium acrylate-sodium 2-acrylamido-2- methylpropanesulfonate copolymer |
37350-42-8 | 15 | 0.00336759 | 3307.9 | ||||
ES-FR 190 | KWS | Friction Reducer | Ethoxylated alcohol | 68439-50-9 | 4 | 0.0037406 | 3674.3 | |
2-Propenoic acid, ammonium salt, polymer with 2-propenamide, Sodium salt |
910644-97-2 | 30 | 0.0280542 | 27556.9 | ||||
Ammonium Acetate | 631-61-8 | 6 | 0.00561085 | 5511.4 | ||||
Water | 7732-18-5 | 40 | 0.0374056 | 36742.6 | ||||
Petroleum Distillate, hydro-treating light | 64742-47-8 | 30 | 0.0280542 | 27556.9 | ||||
Ethoxylated alcohol | 68551-12-2 | 4 | 0.0037406 | 3674.3 | ||||
Acrylamide | 79-06-1 | 0.01 | 0.00000937 | 9.2 | ||||
Ethoxylated alcohol | 68002-97-1 | 4 | 0.0037406 | 3674.3 | ||||
Sorbitan Monooleate | 1338-43-8 | 3 | 0.00280543 | 2755.7 | ||||
Proprietary Surfactant | Proprietary | 3 | 0.00280543 | 2755.7 | ||||
Water | Customer & CWS | Base Fluid & Mix Water | Water | 7732-18-5 | 100 | 90.573 | 88,967,600.0 | |
KR-153SL | KWS | Biocide | Water | 7732-18-5 | 35 | 0.00733451 | 7204.5 | |
Polyethylene glycol | 25322-68-3 | 50 | 0.0104778 | 10292.1 | ||||
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.00419109 | 4116.8 | ||||
Diethylene glycol | 111-46-6 | 3.5 | 0.0007334 | 720.4 |
For data sources see[5]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
2015-06-13 | 0 | 0 | 0 |
For data sources see[6]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2014 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2015 | CNX GAS CO LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | CNX GAS CO LLC | 2,089,281.86 | 366 | 0.00 | 0 | 303.55 | 335 |
2017 | CNX GAS CO LLC | 1,705,133.94 | 365 | 0.00 | 0 | 59.44 | 146 |
2018 | CNX GAS CO LLC | 1,381,089.45 | 365 | 0.00 | 0 | 63.05 | 56 |
2019 | CNX GAS CO LLC | 1,044,608.81 | 365 | 0.00 | 0 | 5.82 | 58 |
For data sources see[7]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2014 | CNX GAS CO LLC | Drill Cuttings | 1,117.72 Tons | LANDFILL | PAD059087072 |
2014 | CNX GAS CO LLC | Drilling Fluid Waste | 1,130.60 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2014 | CNX GAS CO LLC | Drilling Fluid Waste | 1,730.66 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 301071 |
2014 | CNX GAS CO LLC | Drill Cuttings | 83.60 Tons | LANDFILL | 06-08438 |
2014 | CNX GAS CO LLC | Drilling Fluid Waste | 588.88 Bbl | LANDFILL | PAD059087072 |
2014 | CNX GAS CO LLC | Drill Cuttings | 17.45 Tons | RESIDUAL WASTE TRANSFER FACILITY | 301071 |
2015 | CNX GAS CO LLC | Fracing Fluid Waste | 3,415.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | CNX GAS CO LLC | Fracturing Fluid Waste | 572.00 Tons | REUSE OTHER THAN ROAD SPREADING | |
2015 | CNX GAS CO LLC | Drilling Fluid Waste | 107.57 Bbl | LANDFILL | PAD059087072 |
2015 | CNX GAS CO LLC | Fracturing Fluid Waste | 20.09 Tons | LANDFILL | UT2300249 |
2015 | CNX GAS CO LLC | Drilling Fluid Waste | 198.35 Bbl | RESIDUAL WASTE TRANSFER FACILITY | 301071 |
2015 | CNX GAS CO LLC | Drill Cuttings | 90.02 Tons | LANDFILL | PAD059087072 |
2016 | CNX GAS CO LLC | Produced Fluid | 166.64 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2016 | CNX GAS CO LLC | Fracturing Fluid Waste | 10,158.16 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | CNX GAS CO LLC | Produced Fluid | 1,339.60 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2016 | CNX GAS CO LLC | Produced Fluid | 1,740.22 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2016 | CNX GAS CO LLC | Produced Fluid | 32,357.22 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2017 | CNX GAS CO LLC | Produced Fluid | 5,171.08 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-10 |
2017 | CNX GAS CO LLC | Produced Fluid | 333.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-16 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,570.43 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2017 | CNX GAS CO LLC | Produced Fluid | 36.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,888.74 Bbl | REUSE (AT WELL PAD) | |
2017 | CNX GAS CO LLC | Produced Fluid | 1,736.80 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,375.09 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2017 | CNX GAS CO LLC | Produced Fluid | 917.88 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2017 | CNX GAS CO LLC | Produced Fluid | 1,699.05 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2017 | CNX GAS CO LLC | Produced Fluid | 176.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-32 |
2018 | CNX GAS CO LLC | Produced Fluid | 83.80 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2018 | CNX GAS CO LLC | Produced Fluid | 8,445.81 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2018 | CNX GAS CO LLC | Produced Fluid | 638.00 Bbl | REUSE (AT WELL PAD) | |
2018 | CNX GAS CO LLC | Produced Fluid | 527.40 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2018 | CNX GAS CO LLC | Produced Fluid | 1,646.64 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2018 | CNX GAS CO LLC | Produced Fluid | 107.20 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | CNX GAS CO LLC | Produced Fluid | 1,150.20 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2018 | CNX GAS CO LLC | Produced Fluid | 17.00 Bbl | INJECTION DISPOSAL WELL | 34-013-20609 |
2019 | CNX GAS CO LLC | Produced Fluid | 4,752.20 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 789.35 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | CNX GAS CO LLC | Produced Fluid | 70.08 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 30.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | CNX GAS CO LLC | Produced Fluid | 433.00 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-17 |
2019 | CNX GAS CO LLC | Other Oil & Gas Wastes | 20.00 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 74.49 Bbl | INJECTION DISPOSAL WELL | 34-119-28803 |
2019 | CNX GAS CO LLC | Produced Fluid | 17.00 Bbl | INJECTION DISPOSAL WELL | 34-119-28780 |
2019 | CNX GAS CO LLC | Produced Fluid | 682.60 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-21 |
2019 | CNX GAS CO LLC | Produced Fluid | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | CNX GAS CO LLC | Produced Fluid | 198.00 Bbl | REUSE (AT WELL PAD) | |
2019 | CNX GAS CO LLC | Produced Fluid | 1,463.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | CNX GAS CO LLC | Drilling Fluid Waste | 35.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY |
For data sources see[8]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2261617 | Primary Facility | 2014-04-08 | Drilling/Alteration | No Violations Noted | Redstone drilling for CNX. Cellars in place and 30" conductor set to 100ft. Containment under rig and support equipment. HAD drilling moving rig onto site. |
2271586 | Primary Facility | 2014-04-30 | Drilling/Alteration | No Violations Noted | HAD drilling for CNX using closed loop system and flare stack. Currently running survey. Current depth is 1586. BOP tested good at nipple up. Containment under rig and support equipment in good condition. |
2288413 | Primary Facility | 2014-07-17 | Drilling/Alteration | No Violations Noted | HAD Drilling Rig 200 moved onto this well on 4/22/14 and began drilling at 113 ft. |
2312270 | Primary Facility | 2014-10-10 | Routine/Complete Inspection | No Violations Noted | |
2316119 | Primary Facility | 2014-10-28 | Incident- Response to Accident or Event | In Compliance with Policy | On Friday, October 17, 2014, the Department received a telephone call from Andrew Pyrme(?) of CONSOL Energy of a 3-gallon spill of synthetic mud, somewhere, sometime. |
2320153 | Primary Facility | 2014-11-07 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #331 |
2321920 | Primary Facility | 2014-11-17 | Complaint Inspection | No Violations Noted | Patterson UTI rig 331 up and drilling. ID sign along road. |
2324707 | Primary Facility | 2014-10-21 | Drilling/Alteration | No Violations Noted | Horizontal Marcellus, Patterson # 331 start moving on to Bedillion 61 CHS well. |
2443985 | Primary Facility | 2015-11-17 | Routine/Complete Inspection | No Violations Noted | The operator reported a spill of approx. 5 gallons of reuse water on 11/16/15, which was released to secondary containment and then discharged to the well pad. The operator reported that the impacted material was cleaned up to be disposed of. Stained gravel was noted around the containment for the reuse off load point for the AST on site. I spoke with the operator and stated that visual cleanup associated with a small spill cleanup needed to be all visual impacted material and that the noted stained gravel needed to be removed and disposed of. |
2482123 | Primary Facility | 2016-04-26 | Routine/Complete Inspection | No Violations Noted | Well drilled to completion and capable of production. |
2532824 | Primary Facility | 2016-10-17 | Routine/Complete Inspection | No Violations Noted | Well drilled to completion. Well equiped for production. |
2549432 | Primary Facility | 2017-01-04 | Site Restoration | No Violations Noted | |
2651321 | Primary Facility | 2017-10-04 | Site Restoration | No Violations Noted | On October 4, 2017, the Department performed an inspection of the CNX NV61 well pad. The site is located in East Finley Twp., Washington Co. The inspection was related to a well restoration report, for the wells drilled on site, by the operator
The well pad access road and well pad are in good condition. The site has been restored and PCSMs (Infiltration berms) have been installed. The well pad has been reduced in size and vegetated. The operator CNX has terminated the ESCGP2 permit for the site. New stone was placed by the operator near the production fluid storage tanks and a roll off box with stone was noted on the production pad. Kyle Borden (CNX), stated that a truck off loading the production fluid tanks had a malfunction and released oil to the production pad. The trucking company had cleaned up the small release. 5 wells have been drilled to completion and are equipped for production on site. The GPUs on site are not in secondary containment. The operator will need to place the GPUs into cont |