{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.161672,"lon":-80.021183,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Somerset Township | |
Operator Name: RICE DRILLING B LLC | |
Well Pad ID: 153157 | |
Farm/Lease Name: PAPA BEAR 10H | |
License Status: | |
Spud Date: 2016-01-14 | |
Permit Date: 2015-11-23 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.161672 | |
Longitude: -80.021183 |
Date | Event |
---|---|
Deviated | |
Newly Drilled | |
2015-11-23 | New Permit Application |
2016-01-12 | Performed Spud Operation |
2016-01-29 | Drilling Completion |
2016-04-27 | Drilling Completion |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2016 | RICE DRILLING B LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | RICE DRILLING B LLC | 3,726,498.16 | 250 | 0.00 | 0 | 0.00 | 0 |
2018 | RICE DRILLING B LLC | 3,597,882.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | RICE DRILLING B LLC | 2,453,550.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2016 | RICE DRILLING B LLC | Drilling Fluid Waste | 101.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 3,009.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 32.46 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016 | RICE DRILLING B LLC | Produced Fluid | 14.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2016 | RICE DRILLING B LLC | Drilling Fluid Waste | 434.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | RICE DRILLING B LLC | Drill Cuttings | 525.37 Tons | LANDFILL | 100620 |
2016 | RICE DRILLING B LLC | Produced Fluid | 27.60 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | RICE DRILLING B LLC | Produced Fluid | 951.93 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2016 | RICE DRILLING B LLC | Drilling Fluid Waste | 39.00 Bbl | CENTRALIZED TREATMENT PLANT FOR RECYCLE | WMGR123SW019 |
2016 | RICE DRILLING B LLC | Drill Cuttings | 393.89 Tons | LANDFILL | 100172 |
2016 | RICE DRILLING B LLC | Servicing Fluid | 1.86 Tons | LANDFILL | 100592 |
2016 | RICE DRILLING B LLC | Drill Cuttings | 535.78 Tons | LANDFILL | 100663 |
2016 | RICE DRILLING B LLC | Produced Fluid | 158.10 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123SW005 |
2016 | RICE DRILLING B LLC | Synthetic Liner Materials | 12.80 Tons | LANDFILL | 100663 |
2017 | RICE DRILLING B LLC | Produced Fluid | 44.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | |
2017 | RICE DRILLING B LLC | Produced Fluid | 33.92 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2017 | RICE DRILLING B LLC | Soil Contaminated by Oil & Gas Related Spills | 71.24 Tons | LANDFILL | CID # 28726 |
2017 | RICE DRILLING B LLC | Synthetic Liner Materials | 22.54 Tons | LANDFILL | 100663 |
2017 | RICE DRILLING B LLC | Filter Socks | 0.08 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2017 | RICE DRILLING B LLC | Produced Fluid | 15.61 Bbl | INJECTION DISPOSAL WELL | 34-157-25511 |
2017 | RICE DRILLING B LLC | Produced Fluid | 31.74 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2017 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 536.16 Bbl | REUSE (AT WELL PAD) | |
2017 | RICE DRILLING B LLC | Produced Fluid | 8,551.69 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2017 | RICE DRILLING B LLC | Produced Fluid | 2,958.95 Bbl | REUSE (AT WELL PAD) | |
2017 | RICE DRILLING B LLC | Produced Fluid | 9.54 Tons | RESIDUAL WASTE PROCESSING FACILITY | ODNR 2015-511 |
2017 | RICE DRILLING B LLC | Drilling Fluid Waste | 226.80 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | RICE DRILLING B LLC | Unused Fracturing Fluid Waste | 5.98 Tons | LANDFILL | 100663 |
2017 | RICE DRILLING B LLC | Waste Water Treatment Sludge | 15.34 Tons | RESIDUAL WASTE PROCESSING FACILITY | 2014-541 |
2017 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 1,049.02 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | RICE DRILLING B LLC | Produced Fluid | 0.27 Tons | LANDFILL | 100172 |
2017 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 0.02 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2017 | RICE DRILLING B LLC | Soil Contaminated by Oil | 0.40 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2017 | RICE DRILLING B LLC | Soil Contaminated by Oil & Gas Related Spills | 0.40 Tons | RESIDUAL WASTE PROCESSING FACILITY | 301280 |
2017 | RICE DRILLING B LLC | Produced Fluid | 21.20 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2017 | RICE DRILLING B LLC | Produced Fluid | 37.79 Tons | LANDFILL | 100663 |
2017 | RICE DRILLING B LLC | Servicing Fluid | 0.33 Tons | RESIDUAL WASTE TRANSFER FACILITY | 101532 |
2017 | RICE DRILLING B LLC | Produced Fluid | 5,960.65 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | RICE DRILLING B LLC | Produced Fluid | 58.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2017 | RICE DRILLING B LLC | Produced Fluid | 15.32 Tons | LANDFILL | 100592 |
2017 | RICE DRILLING B LLC | Soil Contaminated by Oil | 71.24 Tons | LANDFILL | CID # 28726 |
2018 | RICE DRILLING B LLC | Produced Fluid | 812.37 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2018 | RICE DRILLING B LLC | Produced Fluid | 69.76 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | RICE DRILLING B LLC | Produced Fluid | 695.46 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2018 | RICE DRILLING B LLC | Produced Fluid | 20.17 Bbl | INJECTION DISPOSAL WELL | 34-167-29543 |
2018 | RICE DRILLING B LLC | Produced Fluid | 31.11 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
2018 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 22.00 Bbl | REUSE (AT WELL PAD) | |
2018 | RICE DRILLING B LLC | Produced Fluid | 2,166.68 Bbl | REUSE (AT WELL PAD) | |
2019 | RICE DRILLING B LLC | Produced Fluid | 48.85 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | RICE DRILLING B LLC | Produced Fluid | 40.80 Bbl | SURFACE IMPOUNDMENT | 95-7-37312-19 |
2019 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 28.22 Bbl | REUSE (AT WELL PAD) | |
2019 | RICE DRILLING B LLC | Produced Fluid | 1,904.30 Bbl | REUSE (AT WELL PAD) | |
2019 | RICE DRILLING B LLC | Produced Fluid | 75.63 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW010 |
2019 | RICE DRILLING B LLC | Other Oil & Gas Wastes | 44.00 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA | |
2019 | RICE DRILLING B LLC | Produced Fluid | 89.66 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2019 | RICE DRILLING B LLC | Produced Fluid | 76.22 Bbl | REUSE AT A WELL PAD OUTSIDE PENNSYLVANIA |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2440932 | Primary Facility | 2016-01-14 | Drilling/Alteration | No Violations Noted | Butch’s Rat Hole Service auger rig
Drilled a 36” wellbore and set 26” conductor casing at 40 ft. on 1/14/16. |
2442353 | Primary Facility | 2016-01-21 | Drilling/Alteration | No Violations Noted | Falcon Drilling Rig #23
Moved onto this well on 1/15/15 and resumed drilling at 40ft. The 20” casing was set at 288 ft. on 1/18/16 and cemented to surface with 25 bbls returned. The 13 3/8” casing was set at 508 ft. on 1/20/16. Operator attempted to cement to surface and got gel to surface. Cement fell and casing was grouted to surface with 14 bbls. Coal was found from 420 ft. to 434 ft. A basket was set at 405 ft. Currently at 510 ft. and welding on well head. |
2447712 | Primary Facility | 2016-02-05 | Drilling/Alteration | No Violations Noted | Falcon Drilling Rig #23
The 9 5/8” casing was set at 1886 ft. on 1/24/16 and cemented to surface with 20 bbls returned. TD was at 6080 ft. on 1/29/16. |
2462497 | Primary Facility | 2016-01-08 | Preoperation Inspection | No Violations Noted | |
2462534 | Primary Facility | 2016-01-13 | Routine/Complete Inspection | No Violations Noted | |
2477216 | Primary Facility | 2016-04-21 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #349
Moved onto this well on 4/21/16. Currently rigging up and preparing to TIH and resume drilling. |
2480648 | Primary Facility | 2016-05-03 | Drilling/Alteration | No Violations Noted | Patterson-UTI Drilling Rig #349
Moved onto this well on 4/21/16 and resumed drilling at 6098 ft. KB. KOP was at 7756 ft. MD (7108 ft. TVD). EOB on the curve was at 8938 ft. MD (7954 ft. TVD). TD was at 18,658 ft. MD (7713.18 ft. TVD) on 4/27/16. The 5 ½” casing was set at 18,647 ft. and cemented to surface with 2 bbls returned. |
2550845 | Primary Facility | 2017-01-01 | Drilling/Alteration | No Violations Noted | The department was called out by PEMA for a fire on the Rice Papa Bear pad at approximately 16:03 on January 1st, 2017. Upon arrival at well site at approximately 17:50 the majority of the fire had been extinguished using firefighting foam. Foam was still being applied and used to extinguish truck tires that had not yet been fully extinguished. The department conducted an inspection of fracing equipment, wellheads and the containment on the pad. The fire appeared to be limited to the area around the frac pumping truck units and associated equipment. Several pump trucks were severely damaged with other equipment requiring further inspection to determine damage and safe operation ability. |
2560630 | Primary Facility | 2017-01-03 | Drilling/Alteration | No Violations Noted | Inspect location for progress in cleanup and preparation for final frac work to be completed after service company inspects iron and equipment exposed to fire. In process. NOVIO |
2561000 | Primary Facility | 2017-01-11 | Drilling/Alteration | No Violations Noted | Inspect location for progress in cleanup and preparation for final frac. Company safety representative indicates fracing operations to start tomorrow. All pressure equipment has been replaced and/or repaired as needed for safe operation. Reminded operator that psi test and stimulation notifications still required. NOVIO |
2561048 | Primary Facility | 2017-01-12 | Drilling/Alteration | No Violations Noted | Retrieved old and set new wireline plug on 4H. Frac on 8H halted to flow back well due to higher than anticipated frac pressures. NOVIO |
2614251 | Primary Facility | 2017-04-26 | Follow-up Inspection | No Violations Noted | On 4/26/17 a follow up inspection was conducted of the Papa Bear Well Site in response to an incident (CTS ID: 324312) that occurred on 1/1/17. The following was observed:
>The site appeared to be in generally good condition with no visible residual impacts from the fire. >Two graveled areas were found at the site's stream crossing directly adjacent to the delineated wetlands there. Wetland vegetation was observed encroaching on disturbed and graveled areas. Minor modifications should be added to site plans. No violation. >Secondary containment around equipment on site was intact and adequately maintained. >The site appeared to be in generally good condition with no visible residual impacts from the fire. |
2616988 | Primary Facility | 2017-07-07 | Incident- Response to Accident or Event | Viol(s) Noted & Immediately Corrected | On 7/7/17 an INCDT inspection of the Papa Bear site was conducted in response to an operator reported spill of 25-30 gallons of produced water on 7/6/17 (CTS ID: 328060). The following was observed:
>>The pull offs near the stream crossing on the site access road noted during previous inspections had been removed and vegetated as reported by the operator. >>The operator reported that while servicing well equipment an undrained section of pipe leaked 25-30 gallons of production water to the pad. Excavation of the impacted materials had been completed at the time of inspection with no further indication of contamination. This constitutes a violation of 25 Pa. Code 78.54 and 25 Pa. Code 78.57(a) in that the operator failed to contain production fluids. >>Servicing of site equipment was ongoing at the time of inspection. |
2747951 | Primary Facility | 2018-07-02 | Routine/Complete Inspection | No Violations Noted | This well has been completed and is producing. Wells and site appear to be well maintained. |
2776289 | Primary Facility | 2018-05-03 | Compliance Evaluation | No Violations Noted | On 5/3/18 a complaint evaluation inspection was conducted at the Papa Bear Well Site in response to CTS ID 328060. No evidence of residual contamination found. Complaint closed. |
2780717 | Primary Facility | 2018-09-27 | Follow-up Inspection | No Violations Noted | On 9/27/18 a routine partial inspection of the Papa Bear Well Site was conducted in response to a bulk earth moving notice related to a major modification at the site.
>>Earth moving was underway at the time of inspection with no noted issues. >>Major modification plans as well as original plans are included in the site photos. Plans include conversion of site sediment traps into wet ponds as well as reducing impermeable surfaces on the site. |
2780719 | Primary Facility | 2018-09-27 | Follow-up Inspection | No Violations Noted | On 9/27/18 a routine partial inspection of the Papa Bear Well Site was conducted in response to a bulk earth moving notice related to a major modification at the site.
>>Earth moving was underway at the time of inspection with no noted issues. >>Major modification plans as well as original plans are included in the site photos. Plans include conversion of site sediment traps into wet ponds as well as reducing impermeable surfaces on the site. |
2787120 | Primary Facility | 2018-10-10 | Routine/Partial Inspection | No Violations Noted | On 10/10/18 a routine partial inspection was conducted in response to an operator request for minor modification review. The operator request for a minor modification involving adding an estimated 45' gravel reinforcement to prevent erosion on the edge of wet pond 2 was approved. |
2825533 | Primary Facility | 2019-01-11 | Compliance Evaluation | No Violations Noted | On 1/11/19 a compliance evaluation inspection of the Papa Bear Site was conducted in response to violations noted on 1/3/17. The following was observed:
>>No residual impact was found in the area of the spill. >>The site was found to be in good condition with no violations found. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2616988 | 791748 | 2017-07-07 | 2017-07-07 | 78.54 | Environmental Health & Safety | The operator reported that while servicing well equipment an undrained section of pipe leaked 25-30 gallons of production water to the pad. Excavation of the impacted materials had been completed at the time of inspection with no further indication of contamination. This constitutes a violation of |
2616988 | 791749 | 2017-07-07 | 2017-07-07 | 78.57(a) | Environmental Health & Safety | The operator reported that while servicing well equipment an undrained section of pipe leaked 25-30 gallons of production water to the pad. Excavation of the impacted materials had been completed at the time of inspection with no further indication of contamination. This constitutes a violation of |