{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.067408,"lon":-80.396808,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: East Finley Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 153510 | |
Farm/Lease Name: JT FARM 593014 | |
License Status: | |
Spud Date: | |
Permit Date: 2017-01-25 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: Yes | |
Latitude: 40.067408 | |
Longitude: -80.396808 |
Date | Event |
---|---|
2017-01-25 | New Permit Application |
2017-06-23 | Performed Spud Operation |
2017-11-29 | MOD |
2018-10-29 | MOD |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2017 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2019 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2017 | EQT PROD CO | Drill Cuttings | 236.67 Tons | LANDFILL | 100663 |
2017 | EQT PROD CO | Drill Cuttings | 779.44 Tons | LANDFILL | 100172 |
2017 | EQT PROD CO | Synthetic Liner Materials | 15.19 Tons | LANDFILL | 100663 |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 360.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Other Oil & Gas Wastes | 219.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Drilling Fluid Waste | 110.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2017 | EQT PROD CO | Produced Fluid | 115.00 Bbl | REUSE (AT WELL PAD) | |
2017 | EQT PROD CO | Drilling Fluid Waste | 465.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Drill Cuttings | 162.10 Tons | LANDFILL | 06-08438 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 33.33 Tons | LANDFILL | 100172 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 144.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 82.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW005 |
2019 | EQT PROD CO | Other Oil & Gas Wastes | 4.66 Tons | LANDFILL | 100419 |
2019 | EQT PROD CO | Drilling Fluid Waste | 350.00 Bbl | REUSE (AT WELL PAD) | |
2019 | EQT PROD CO | Drill Cuttings | 1,493.06 Tons | LANDFILL | 100172 |
2019 | EQT PROD CO | Drill Cuttings | 334.17 Tons | LANDFILL | 100419 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2586320 | Primary Facility | 2017-04-17 | Routine/Complete Inspection | No Violations Noted | On 4/17/2017, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was performed as a routine inspection during construction of the site.
The Act 9 site ID sign was in place and legible. The access road to the well pad has been constructed. The operator has completed construction of the southeast section of the well pad and fill slope. During the inspection the operator was in process of constructing the toe key for the northwest well pad fill slope. All perimeter E&S BMPs have been installed for the access road and well pad which are functional. The trees have been cleared for the entire site and the operator was in process of installing E&S BMPs for the AST pad and freshwater impoundment. 5 wells have been permitted to be drilled on site. |
2608269 | Primary Facility | 2017-06-26 | Drilling/Alteration | No Violations Noted | Operator reports 30" hole drilled to 40' with 26" conductor grouted to surface through 1" tubing. Site inspection shows no apparent viloation. NOVIO |
2615051 | Primary Facility | 2017-06-01 | Preoperation Inspection | No Violations Noted | On June 1, 2017, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was performed as a pre-operational inspection during construction of the site before the commencement of drilling.
The Act 9 site ID sign was in place and legible. The access road to the well pad has been constructed. The operator has completed construction of the well pad and fill slope. During the inspection the operator was in process of stoning the pad in preparation of drilling on site. The operator has started construction of the freshwater impoundment for the site. All perimeter E&S BMPs have been installed for the site and are functional. 5 wells have been permitted to be drilled on site. |
2618316 | Primary Facility | 2017-07-23 | Routine/Complete Inspection | No Violations Noted | Operator reports 18 5/8" csg set to 566' with 40 Bbls of cmt returns. NOVIO |
2629583 | Primary Facility | 2017-07-25 | Routine/Complete Inspection | No Violations Noted | Operator reports 13 3/8" csg set to 866' with 23 Bbls of cmt returns. NOVIO |
2629604 | Primary Facility | 2017-08-09 | Routine/Complete Inspection | No Violations Noted | Operator reports 9 5/8" csg set to 3006' with 25 Bbls of cmt returns. NOVIO |
2679917 | Primary Facility | 2018-01-03 | Routine/Complete Inspection | No Violations Noted | On January 3, 2018, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was a routine inspection before resumption of drilling activity on the site.
The site was covered with snow at time of inspection. The access road and well pad are in good condition. The operator has begun filing the freshwater impoundment on site. PCSM structures have not been installed, and all E&S BMPs have been installed and are functional. The operator has permitted 12 wells on site and has drilled the vertical section for five of these wells. The operator plans to revisit the site spud the remaining seven permitted wells for the site and complete drilling operations to TD for all 12 permitted wells for the site. 5 Spud wells with vertical section of well drilled. JT Farm 593014 JT Farm 593015 JT Farm 593016 JT Farm 593017 JT Farm 593018 7 permitted but not drilled wells. JT Farm 593019 JT Farm 593020 JT Farm 593021 JT Farm 593022 |
2833315 | Primary Facility | 2019-01-10 | Routine/Complete Inspection | No Violations Noted | On January 10, 2019, the Department performed an inspection of the EQT JT Farm well pad site. The site is located in East Finley Twp., Washington Co. The inspection was related to a request by the operator for a minor modification to the ESCGP2 permit.
The operator has requested a minor modification to the ESCGP2 permit to construct a fresh water pipeline, and gathering pipeline within the well pad LOD to connect to the Equitrans NIPI-S002 pipeline site. The minor modification was reviewed and approved by the Department in the field. The modified ESCGP2, E&S plans were redlined by the Department and left in the mailbox on site as the official plans for the site. The well pad and access road where in good condition. The operator plans to return to the site in the near future to complete drilling operations for the 12 permitted wells on the site. 5 wells have the vertical sections for those wells completed and are on inactive status at this current time. |