If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-125-28484 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.265528,"lon":-80.187675,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Washington | |
Municipality: Canonsburg Borough | |
Operator Name: UNKNOWN OPR | |
Well Pad ID: | |
Farm/Lease Name: | |
License Status: | |
Spud Date: | |
Permit Date: | |
Well Type: COMB. OIL&GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.265528 | |
Longitude: -80.187675 |
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2654536 | Primary Facility | 2017-09-20 | Routine/Complete Inspection | No Viols - Permanently Shut Down | Visited site with representatives from DEP, Columbia Gas representative and property owner. Columbia found stray gas in yard but not in house. Owner said an abandoned well was reported to be buried beneath the blacktop beside the house,~3 feet from house. Well is under what is currently a closed-in storage area beneath steps at the side of the house. Checked basement of house for stray gas, none detected in air, drains etc. Advised homeowner to install methane detectors in storage area and inside basement. |
2791222 | Primary Facility | 2018-10-18 | Routine/Partial Inspection | No Viols - Permanently Shut Down | Visited site with Echelon to determine the best remediation plan for the stray gas detected in the front yard. In addition to stray gas hot spots in yard, a 6"-8" wide area between the small enclosure beneath the side steps and the cement slab retaining wall had stray gas readings of 7-8% gas. |
2794420 | Primary Facility | 2018-10-25 | Follow-up Inspection | No Viols - Permanently Shut Down | Visited site to get Contractual Consent of Landowner form signed for proposed stray gas remediation. |
2804851 | Primary Facility | 2018-11-19 | Follow-up Inspection | No Viols - Permanently Shut Down | Echelon on site to begin remediation work. Hand-dug trench between wall and enclosure below porch. Installed gravel and perforated PVC pipe on gravel, ran pipe up to side of house, converted to downspout pipe, ran up to roofline and capped with wind turbine. Piping began venting gas as soon as it was installed. Unable to excavate trench in front yard, due to rain. Will return tomorrow, weather permitting. |
2805933 | Primary Facility | 2018-11-21 | Routine/Partial Inspection | In Compliance with Policy | Echelon completed trench and vent installation yesterday. They were on site earlier today to do touchup work on grading and mulch on front yard. Spoke to property owner who was pleased with the work done. |
2826185 | Primary Facility | 2018-12-10 | Routine/Partial Inspection | In Compliance with Policy | Visited site to check gas levels of new vent stacks. Calm morning, 24 degrees. Both readings with Bascom Turner meter:
porch stack 0% LEL yard stack 29% LEL. |
2830333 | Primary Facility | 2019-01-02 | Routine/Partial Inspection | In Compliance with Policy | Visited site to check gas levels of vent stacks. Calm morning. Both readings with Bascom Turner meter:
porch stack 1360 PPM yard stack 8880 PPM |
2831028 | Primary Facility | 2019-01-22 | Routine/Partial Inspection | In Compliance with Policy | Visited site to check gas levels of vent stacks. Calm morning, near zero temp. Both readings with Bascom Turner meter:
porch stack 120 PPM yard stack 32 LEL |
2838824 | Primary Facility | 2019-02-04 | Routine/Partial Inspection | In Compliance with Policy | Visited site to check gas levels of vent stacks. Still to slightly breezy AM. Both readings with Bascom Turner meter:
porch stack 0 PPM yard stack 37 LEL |